A New Calibration Procedure for Gel Filtration Columns
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A new procedure for column calibration is described based on the assumption that microregions of nonexcluded volume within the gel are distributed randomly with respect to the sizes of molecules they can accommodate. This approach leads to a linear relationship between molecular radius and the inverse error function complement of the column partition coefficient. Excellent agreement of the relationship is obtained with experimental data over a wide range of molecular size as well as a diversity of molecular species and column bed materials. The new method is simple and convenient to use and has the advantage over previous methods in that it is not based on any hypothetical structures for the gel matrix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of the molecular weights of proteins by Sephadex gel-filtration
Andrews, P. (1964) · Biochemical Journal · doi:10.1042/bj0910222 · Cited by 3,899
The gel-filtration behaviour of proteins related to their molecular weights over a wide range
Andrews, P. (1965) · Biochemical Journal · doi:10.1042/bj0960595 · Cited by 3,046
Siegel, L. M., & Monty, K. J. (1966) · Biochimica et Biophysica Acta (BBA) - Biophysics including Photosynthesis · doi:10.1016/0926-6585(66)90333-5 · Cited by 2,226
A theory of gel filtration and its exeperimental verification
Laurent, T. C., & Killander, J. (1964) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)86637-6 · Cited by 1,544
Determination of Molecular Weights of Proteins by Gel Filtration of Sephadex.
Whitaker, J. R. (1963) · Analytical Chemistry · doi:10.1021/ac60205a048 · Cited by 1,307
Porath, J. (1963) · Pure and Applied Chemistry · doi:10.1351/pac196306030233 · Cited by 407
Determination of the structure of agarose gels by gel chromatography
Laurent, T. C. (1967) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(67)90064-5 · Cited by 128
Cited by
Polyacrylamide Gel Electrophoresis
Chrambach, A., & Rodbard, D. (1971) · Science · doi:10.1126/science.172.3982.440 · Cited by 794
Estimation of Molecular Size and Molecular Weights of Biological Compounds by Gel Filtration
Andrew, P. (1970) · Methods of Biochemical Analysis · doi:10.1002/9780470110362.ch1 · Cited by 638
MacLean-Fletcher, S., & Pollard, T. D. (1980) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(80)91175-4 · Cited by 465
Uversky, V. N. (1993) · Biochemistry · doi:10.1021/bi00211a042 · Cited by 437
Single bilayer vesicles prepared without sonication physico-chemical properties
Brunner, J., Skrabal, P., & Hausser, H. (1976) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(76)90308-4 · Cited by 383
Metadata
- Authors
- Ackers, G. K.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1967-07
- Volume
- 242
- Issue
- 13
- Pages
- 3237-3238
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1533372454
- Cited by
- 412
- References
- 7
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.