Real time measurement of nitric oxide produced ex vivo by luminol-H2O2 chemiluminescence method.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Endothelium-derived relaxing factor, identified as nitric oxide (NO), is derived from a guanidino nitrogen of L-arginine via its metabolism by nitric oxide synthase. A newly developed aqua-chemiluminescence system was used to measure the amount of NO release from the isolated, perfused rat kidney concomitantly with the pressure changes (Kikuchi, K., Nagano, T., Hayakawa, H., Hirata, Y., and Hirobe, M. (1993) Anal. Chem. 65, 1794-1799). In normotensive rats, basal NO release was estimated to be 86 +/- 6 fmol min-1 (g of kidney weight)-1, and endothelium-dependent vasodilators increased NO release with a concomitant pressure reduction. Pretreatment of the kidney with detergents to damage the vascular endothelium diminished the responses of NO and perfusion pressure to acetylcholine, while infusion of authentic NO solution caused an increase in the chemiluminescence and a concomitant decrease in the pressure. The half-life of NO in O2-saturated Krebs-Henseleit buffer was determined as 6.41 s, and the decay constant (Kd) was 0.108 s-1. The measuring system involves a lag time of 15 s after passage of the solution through the kidney, so that the measured value is 13.0% of the true luminal NO concentration in the kidney, up to 400 pM. These observations enabled us to quantitate the degree to which NO released from the rat kidney changes perfusion pressure. Acetylcholine-induced vasodilation and NO release were markedly attenuated in deoxycorticosterone acetate-salt hypertensive rats, in which the endothelium is known to be markedly damaged. Thus, this assay system may make it possible to evaluate the extent of injury to the endothelium in conditions involving vascular damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide mediates glutamate-linked enhancement of cGMP levels in the cerebellum.
Bredt, D. S., & Snyder, S. H. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.22.9030 · Cited by 1,966
Cited by
Detection and Imaging of Nitric Oxide with Novel Fluorescent Indicators: Diaminofluoresceins
Kojima, H., Nakatsubo, N., Kikuchi, K., Kawahara, S., Kirino, Y., Nagoshi, H., Hirata, Y., & Nagano, T. (1998) · Analytical Chemistry · doi:10.1021/ac9801723 · Cited by 1,389
Self-citationNitric Oxide: The Versatility of an Extensive Signal Molecule
Lamattina, L., García-Mata, C., Graziano, M., & Pagnussat, G. (2003) · Annual Review of Plant Biology · doi:10.1146/annurev.arplant.54.031902.134752 · Cited by 877
Natural products ? a simple model to explain chemical diversity
Firn, R. D., & Jones, C. G. (2003) · Natural Product Reports · doi:10.1039/b208815k · Cited by 467
Nagano, T., & Yoshimura, T. (2002) · Chemical Reviews · doi:10.1021/cr010152s · Cited by 414
Self-citationSasaki, E., Kojima, H., Nishimatsu, H., Urano, Y., Kikuchi, K., Hirata, Y., & Nagano, T. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042967z · Cited by 405
Self-citation
Metadata
- Authors
- Kikuchi, K., Nagano, T., Hayakawa, H., Hirata, Y., & Hirobe, M.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1993-11
- Volume
- 268
- Issue
- 31
- Pages
- 23106-23110
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1502711475
- Cited by
- 101
- References
- 1
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real time measurement of nitric oxide produced ex vivo by luminol-H2O2 chemiluminescence method. https://app.cochat.ai/papers/10.1016/s0021-9258(19)49432-5
- The paper
- Kikuchi, K., Nagano, T., Hayakawa, H., Hirata, Y., & Hirobe, M. (1993). Real time measurement of nitric oxide produced ex vivo by luminol-H2O2 chemiluminescence method. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(19)49432-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.