The DOI matches its Crossref record.
A SPECTROPHOTOMETRIC METHOD FOR MEASURING THE BREAKDOWN OF HYDROGEN PEROXIDE BY CATALASE
Open accessAbstract
Several methods have been developed for following the breakdown of hydrogen peroxide catalyzed by catalase, but these either have not been sufficiently quantitative or have not proved rapid enough to yield reliable data during the critical 1st or 2nd minute of the reaction. Chemical pro-cedures in which residual peroxide is titrated with permanganate (l-3) or an excess of permanganate is measured calorimetrically (4) are accurate except for reaction times of less than a minute, although Lemberg and Foulkes (5) developed a micromethod for obtaining data every 10 seconds (see also Ogura et al. (6)). Considerable variability is unavoidable, how-ever, when samples must-be taken at such short intervals. The manometric method for measuring oxygen evolved from the system proved in detailed studies to be unsuited for following the rapid breakdown of peroxide in which a diffusion process across the liquid-air interface becomes limiting. This is manifested by changes in both the order of the reaction and the rate of evolution of oxygen with variations in the rate of agitation of the reaction mixture (7). Direct measurement of hydrogen peroxide by polar-ography provides good quantitative data during the 1st minute of the reaction which fit first order kinetics (8). However, an elaborate, special, electronic circuit is needed for such measurements. Furthermore, as pointed out by Bonmschen, Chance, and Theorell (8), this method appears to give lower values for catalase activity than do titration techniques. Preliminary experiments for following the breakdown of hydrogen per-oxide by observing the decrease in light absorption of peroxide solutions in the ultraviolet were reported by Chance (9) and Chance and Herbert (10). The potentialities of this method have been investigated and a quantitative, spectrophotometric technique for following the breakdown of hydrogen peroxide has been developed for routine studies of catalase kinetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
[136] Assay of catalases and peroxidases
Chance, B., & Maehly, A. C. (1955) · Methods in Enzymology · doi:10.1016/s0076-6879(55)02300-8 · Cited by 4,882
The thioredoxin antioxidant system
Lu, J., & Holmgren, A. (2014) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2013.07.036 · Cited by 2,055
de Azevedo Neto, A. D., Prisco, J. T., Enéas-Filho, J., Abreu, C. E. B. D., & Gomes-Filho, E. (2006) · Environmental and Experimental Botany · doi:10.1016/j.envexpbot.2005.01.008 · Cited by 920
Horsburgh, M. J., Aish, J. L., White, I. J., Shaw, L., Lithgow, J. K., & Foster, S. J. (2002) · Journal of Bacteriology · doi:10.1128/jb.184.19.5457-5467.2002 · Cited by 699
Benaroudj, N., Lee, D. H., & Goldberg, A. L. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m101487200 · Cited by 668
Metadata
- Authors
- Beers, R. F., & Sizer, I. W.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1952-03
- Volume
- 195
- Issue
- 1
- Pages
- 133-140
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1768247331
- Cited by
- 6,761
- References
- 0
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A SPECTROPHOTOMETRIC METHOD FOR MEASURING THE BREAKDOWN OF HYDROGEN PEROXIDE BY CATALASE. https://app.cochat.ai/papers/10.1016/s0021-9258(19)50881-x
- The paper
- Beers, R. F., & Sizer, I. W. (1952). A SPECTROPHOTOMETRIC METHOD FOR MEASURING THE BREAKDOWN OF HYDROGEN PEROXIDE BY CATALASE. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(19)50881-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.