In vivo biomechanical behavior of the human heel pad during the stance phase of gait
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Paul, I. L., Munro, M. B., Abernethy, P. J., Simon, S. R., Radin, E. L., & Rose, R. M. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90049-0 · Cited by 123 · cited 1×
“This result resembles the absorbency values of 20–28% measured by Paul et al. (1978) in heel pads of living rabbits, using implanted force transducers.”
The role of the heel pad and shank soft tissue during impacts: a further resolution of a paradox
Pain, M. T. G., & Challis, J. H. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00199-8 · Cited by 103 · cited 2×
“However, it is considerably lower than values of 30–46% obtained for simulated heel strikes using instrumented pendulum apparatuses or a servo-hydraulic (Instron) axial compression testing system (Aerts et al., 1995; Ker, 1996; Pain and Challis, 2001).”
Achillodynia and loss of heel pad shock absorbency
Jørgensen, U. G. (1985) · The American Journal of Sports Medicine · doi:10.1177/036354658501300209 · Cited by 79 · cited 1×
“It is comprised of sealed spiral microchambers of unsaturated fat contained in whorls of fibroelastic tissue, which is anchored to both the dermis (skin) and the calcaneus (Jorgensen, 1985).”
Background
Cited by
Musculoskeletal disorders associated with obesity: a biomechanical perspective
Wearing, S. C., Hennig, E. M., Byrne, N. M., Steele, J. R., & Hills, A. P. (2006) · Obesity Reviews · doi:10.1111/j.1467-789x.2006.00251.x · Cited by 521
Three-dimensional finite element analysis of the foot during standing—a material sensitivity study
Cheung, J. T.-M., Zhang, M., Leung, A. K.-L., & Fan, Y.-B. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.035 · Cited by 449
Plantar soft tissue loading under the medial metatarsals in the standing diabetic foot
Gefen, A. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00029-8 · Cited by 247
“Compression stresses also increased substantially in the simulated diabetic foot, reaching peaks of 76 and 99 KPa on the plantar surfaces under the first and second metatarsal heads, respectively.”
BackgroundInfluentialSelf-citationActive regulation of longitudinal arch compression and recoil during walking and running
Kelly, L. A., Lichtwark, G., & Cresswell, A. G. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.1076 · Cited by 218
Chang, K.-H., Liao, H.-T., & Chen, J.-P. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.046 · Cited by 166
“Using mechanical testing, the instantaneous elastic modulus for adipose tissue was found to be in the range of 3–24 kPa for breast samples [47] and in the range of 24– 180 kPa for heel pad samples [48].”
Background
Metadata
- Authors
- Gefen, A., Megido-Ravid, M., & Itzchak, Y.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2001-12
- Volume
- 34
- Issue
- 12
- Pages
- 1661-1665
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1972094600
- Cited by
- 178
- References
- 3
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.