CoChat

An improved labelling technique for monitoring microcrack growth in compact bone

Open access
O’Brien, Fergal J, Taylor, David, Lee, T.Clive · 2002 · Journal of Biomechanics
Cited by 113

The DOI matches its Crossref record.

Abstract

Fatigue-induced damage plays an important role in bone remodelling and in the formation of stress and fragility fractures. Recently, a technique has been developed (Lee, T.C. et al., Sequential labelling of microdamage in bone using chelating agents. Journal of Orthopedic Research, 18 (2000) 322-325) which allows microcrack growth in trabecular bone to be monitored by the application of a series of chelating fluorochromes, however, some limitations were identified with the process. The aims of this study were to refine the method of detection using these agents in order to determine the optimal sequence of application and the optimal concentrations which allowed all the agents to fluoresce equally brightly using UV epifluorescence. A chemical analysis process, ion chromatography, followed by validation tests on bone samples showed that the optimal sequence of application and concentration of each agent was alizarin complexone (0.0005 M) followed by xylenol orange (0.0005 M), calcein (0.0005 M) and calcein blue (0.0001 M). A fifth agent, oxytetracycline was excluded from the study after recurring problems were found with its ability to chelate exposed calcium when applied in sequence with the other agents. This work has developed a sequential labelling technique, which allows for microcrack propagation during fatigue testing of bone specimens to be monitored without the problem of chelating agent substitution occurring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9290(01)00200-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 113

Metadata

Authors
O’Brien, F. J., Taylor, D., & Lee, T. C.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
2002-04
Volume
35
Issue
4
Pages
523-526
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2016894414
Cited by
113
References
0
FWCI
6.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An improved labelling technique for monitoring microcrack growth in compact bone. https://app.cochat.ai/papers/10.1016/s0021-9290(01)00200-7
The paper
O’Brien, F. J., Taylor, D., & Lee, T. C. (2002). An improved labelling technique for monitoring microcrack growth in compact bone. Journal of Biomechanics. https://doi.org/10.1016/s0021-9290(01)00200-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.