Large index-fingertip forces are produced by subject-independent patterns of muscle excitation
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Are fingertip forces produced by subject-independent patterns of muscle excitation? If so, understanding the mechanical basis underlying these muscle coordination strategies would greatly assist surgeons in evaluating options for restoring grasping. With the finger in neutral ad- abduction and flexed 45 degrees at the MCP and PIP, and 10 degrees at DIP joints, eight subjects attempted to produce maximal voluntary forces in four orthogonal directions perpendicular to the distal phalanx (palmar, dorsal, lateral and medial) and in one direction collinear with it (distal). Forces were directed within 4.7 +/- 2.2 degrees (mean +/- S.D.) of target and their magnitudes clustered into three distinct levels (p < 0.05; post hoc pairwise RMANOVA). Palmar (27.9 +/- 4.1 N), distal (24.3 +/- 8.3 N) and medial (22.9 +/- 7.8 N) forces were highest, lateral (14.7 +/- 4.8 N) was intermediate, and dorsal (7.5 +/- 1.5 N) was lowest. Normalized fine-wire EMGs from all seven muscles revealed distinct muscle excitation groups for palmar, dorsal and distal forces (p < 0.05; post hoc pairwise RMANOVA). Palmar force used flexors, extensors and dorsal interosseous; dorsal force used all muscles; distal force used all muscles except for extensors; medial and lateral forces used all muscles including significant co-excitation of interossei. The excitation strategies predicted to achieve maximal force by a 3-D computer model (four pinjoints, inextensible tendons, extensor mechanism and isometric force models for all seven muscles) reproduced the observed use of extensors and absence of palmar interosseous to produce palmar force (to regulate net joint flexion torques), the absence of extensors for distal force, and the use of intrinsics (strong MCP flexors) for dorsal force. The model could not predict the interossei co-excitation seen for medial and lateral forces, which may be a strategy to prevent MCP joint damage. The model predicts distal force to be most sensitive to dorsal interosseous strength, and palmar and distal forces to be very sensitive to MCP and PIP flexor moment arms, and dorsal force to be sensitive to the moment arm of and the tension allocation to the PIP extensor tendon of the extensor mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,673
Self-citationA Mathmematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. (1994) · Cited by 2,676
Grip and pinch strength: normative data for adults.
Mathiowetz, V. G., Kashman, N., Volland, G., Weber, K., Dowe-Keval, M., & Rogers, S. R. (1985) · PubMed · Cited by 2,154
Neurobiology of muscle fatigue
Enoka, R. M., & Stuart, D. G. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.5.1631 · Cited by 1,429
Clinical mechanics of the hand
Brand, P. W. (1985) · Medical Entomology and Zoology · Cited by 690
Foundations of robotics: analysis and control
(1991) · Choice Reviews Online · doi:10.5860/choice.28-5104 · Cited by 535
Tendon excursion and moment arm of index finger muscles
An, K. N., Ueba, Y., Chao, E. Y., Cooney, W. P., & Linscheid, R. L. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90074-x · Cited by 385
Lieber, R. L., Jacobson, M. D., Fazeli, B. M., Abrams, R. A., & Botte, M. J. (1992) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(92)90444-t · Cited by 369
Long, C., Conrad, P. W., Hall, E. A., et al. (1970) · PubMed · Cited by 282
Clinical Mechanics of the Hand
Seyfer, A. E. (1994) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199404000-00043 · Cited by 279
The relationship between wrist position, grasp size, and grip strength
O'Driscoll, S. W., Horii, E., Ness, R., Cahalan, T. D., Richards, R. R., & An, K.-N. (1992) · The Journal of Hand Surgery · doi:10.1016/0363-5023(92)90136-d · Cited by 266
Normative model of human hand for biomechanical analysis
An, K. N., Chao, E. Y., Cooney, W. P., & Linscheid, R. L. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90163-5 · Cited by 263
Anatomic guide for the electromyographer--the limbs
Delagi, E. F., & Perotto, A. (1980) · Thomas eBooks · Cited by 260
LONG, C., CONRAD, P. W., HALL, E. A., & FURLER, S. L. (1970) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197052050-00001 · Cited by 260
Forces in the normal and abnormal hand
An, K. N., Chao, E. Y., Cooney, W. P., & Linscheid, R. L. (1985) · Journal of Orthopaedic Research · doi:10.1002/jor.1100030210 · Cited by 225
HULLAND, T. J. (1993) · Pathology of Domestic Animals · doi:10.1016/b978-0-08-057133-1.50010-2 · Cited by 214
Architectural design of the human intrinsic hand muscles
Jacobson, M. D., Raab, R., Fazeli, B. M., Abrams, R. A., Botte, M. J., & Lieber, R. L. (1992) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(92)90446-v · Cited by 201
Maier, M. A., & Hepp-Reymond, M.-C. (1995) · Experimental Brain Research · doi:10.1007/bf00241969 · Cited by 188
Effects of hip center location on the moment-generating capacity of the muscles
Delp, S. L., & Maloney, W. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90011-3 · Cited by 186
A biomechanical analysis of muscle strength as a limiting factor in standing posture
Kuo, A. D., & Zajac, F. E. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90085-s · Cited by 174
Self-citationGRAPHICAL INTERPRETATION OF THE SOLUTION TO THE REDUNDANT PROBLEM IN BIOMECHANICS.
Chao, E., & An, K. (1978) · Journal of Biomechanical Engineering · doi:10.1115/1.3426207 · Cited by 92
Maximum Finger Force Prediction Using a Planar Simulation of the Middle Finger
Lee, J. W., & Rim, K. (1990) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1990_204_251_02 · Cited by 62
Rehabilitation and surgical reconstruction of the upper limb in tetraplegia: An update
Hentz, V. R., House, J. H., McDowell, C. L., & Moberg, E. (1992) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(92)90478-8 · Cited by 50
Anatomic Guide for the Electromyographer: The Limbs
Kanakamedala, R. V. (1982) · JAMA · doi:10.1001/jama.1982.03320440065050 · Cited by 25
Cited by
Optimality principles in sensorimotor control
Todorov, E. (2004) · Nature Neuroscience · doi:10.1038/nn1309 · Cited by 1,746
The Dynamics of Legged Locomotion: Models, Analyses, and Challenges
Holmes, P., Full, R. J., Koditschek, D., & Guckenheimer, J. (2006) · SIAM Review · doi:10.1137/s0036144504445133 · Cited by 714
Muscle Synergies Characterizing Human Postural Responses
Torres-Oviedo, G., & Ting, L. H. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01360.2006 · Cited by 551
Neuromechanics of muscle synergies for posture and movement
Ting, L. H., & McKay, J. L. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2008.01.002 · Cited by 514
Hand function: peripheral and central constraints on performance
Schieber, M. H., & Santello, M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01063.2003 · Cited by 483
Metadata
- Authors
- Valero-Cuevas, F. J., Zajac, F. E., & Burgar, C. G.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1998-08
- Volume
- 31
- Issue
- 8
- Pages
- 693-703
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2130732995
- Cited by
- 306
- References
- 25
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.