The DOI matches its Crossref record.
Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry
Open accessAbstract
A simple, sensitive, and specific liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the determination of bile acids in human bile has been developed. The bile acids were extracted with a C(18) (octadecyl) reversed-phase column and identified and quantified by simultaneous monitoring of their parent and daughter ions, using the multiple reaction monitoring mode. Identification and quantification of conjugated bile acids in bile was achieved in 5 min. The detection limit was 1 ng, and the determination was linear for concentrations up to 100 ng. The percent recovery of standards made of single conjugated (glycine and taurine) bile acid or of mixture of glycine- or taurine-conjugated cholic acid, chenodeoxycholic acid, deoxycholic acid, ursodeoxycholic acid, and lithocholic acid averaged 71.73% to 95.92%. The percent recovery of the same standard bile acids was also determined by gas chromatography-mass spectrometry (GC-MS), using the selected ion monitoring mode, and averaged 66% to 96%. A biliary bile acid profile of human gallbladder bile was obtained by LC-MS/MS and GC-MS. The results showed a good correlation between the two techniques and no significant differences between the two methods were observed. The LC-MS/MS method was also used for the analysis of serum, urine, and fecal bile acids. In conclusion, LC-MS/MS is a simple, sensitive, and rapid technique for the analysis of conjugated bile acids in bile and other biological samples. - Perwaiz, S., B. Tuchweber, D. Mignault, T. Gilat, and I. M. Yousef. Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry. J. Lipid Res. 2001. 42: 114;-119.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Psychogios, N., Hau, D. D., Peng, J., Guo, A. C., Mandal, R., Bouatra, S., Sinelnikov, I., Krishnamurthy, R., Eisner, R., Gautam, B., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016957 · Cited by 1,703
Connecting dysbiosis, bile-acid dysmetabolism and gut inflammation in inflammatory bowel diseases
Duboc, H., Rajca, S., Rainteau, D., Benarous, D., Maubert, M.-A., Quervain, E., Thomas, G., Barbu, V., Humbert, L., Despras, G., et al. (2013) · Gut · doi:10.1136/gutjnl-2012-302578 · Cited by 930
Bile acids as carcinogens in human gastrointestinal cancers
Bernstein, H., Bernstein, C., Payne, C. M., Dvorakova, K., & Garewal, H. (2005) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2004.08.001 · Cited by 611
Bile Acid Sulfation: A Pathway of Bile Acid Elimination and Detoxification
Alnouti, Y. (2009) · Toxicological Sciences · doi:10.1093/toxsci/kfn268 · Cited by 390
Bile acids as endogenous etiologic agents in gastrointestinal cancer
Bernstein, H., Bernstein, C., Payne, C. M., & Dvorak, K. (2009) · World Journal of Gastroenterology · doi:10.3748/wjg.15.3329 · Cited by 340
Metadata
- Authors
- Perwaiz, S., Tuchweber, B., Mignault, D., Gilat, T., & Yousef, I. M.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 2001-01
- Volume
- 42
- Issue
- 1
- Pages
- 114-119
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W2101494642
- Cited by
- 186
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry. https://app.cochat.ai/papers/10.1016/s0022-2275(20)32342-7
- The paper
- Perwaiz, S., Tuchweber, B., Mignault, D., Gilat, T., & Yousef, I. M. (2001). Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry. Journal of Lipid Research. https://doi.org/10.1016/s0022-2275(20)32342-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.