All-trans-retinoic acid: measurement of reference values in human serum by high performance liquid chromatography
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A quantitative determination of physiological levels of all-trans-retinoic acid (vitamin A acid) in human serum has been developed. A double-phase extraction of 3.5 ml of serum followed by a specific and sensitive high performance liquid chromatography procedure allowed measurement of levels down to 1 ng/ml. Serum concentrations in 37 fasting volunteers ranged from 2.7 to 4.2 ng/ml and fitted a normal-Gaussian distributional shape with a mean value of 3.5 ng/ml and SD of 0.4 ng/ml, as demonstrated by the Kolmogorov-Smirnov test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Kolmogorov-Smirnov Test for Goodness of Fit
Massey, F. J. (1951) · Journal of the American Statistical Association · doi:10.1080/01621459.1951.10500769 · Cited by 7,210
On the Kolmogorov-Smirnov Test for Normality with Mean and Variance Unknown
Lilliefors, H. W. (1967) · Journal of the American Statistical Association · doi:10.2307/2283970 · Cited by 4,530
Cited by
Cellular Biology and Biochemistry of the Retinoids
ROBERTS, A. B., & SPORN, M. B. (1984) · The Retinoids · doi:10.1016/b978-0-12-658102-7.50012-9 · Cited by 738
Vitamin A and retinoids in health and disease
Epstein, F. H., & Goodman, D. S. (1984) · New England Journal of Medicine · doi:10.1056/nejm198404193101605 · Cited by 553
Plasma Retinol-Binding Protein
GOODMAN, D. S. (1984) · The Retinoids · doi:10.1016/b978-0-12-658102-7.50008-7 · Cited by 268
Quantitative Profiling of Endogenous Retinoic Acid in Vivo and in Vitro by Tandem Mass Spectrometry
Kane, M. A., Folias, A. E., Wang, C., & Napoli, J. L. (2008) · Analytical Chemistry · doi:10.1021/ac702030f · Cited by 230
Wei, S., Episkopou, V., Piantedosi, R., Maeda, S., Shimada, K., Gottesman, M. E., & Blaner, W. S. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.2.866 · Cited by 123
Metadata
- Authors
- De Leenheer, A. P., Lambert, W. E., & Claeys, I.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 1982-12
- Volume
- 23
- Issue
- 9
- Pages
- 1362-1367
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W1751235690
- Cited by
- 156
- References
- 2
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: All-trans-retinoic acid: measurement of reference values in human serum by high performance liquid chromatography. https://app.cochat.ai/papers/10.1016/s0022-2275(20)38042-1
- The paper
- De Leenheer, A. P., Lambert, W. E., & Claeys, I. (1982). All-trans-retinoic acid: measurement of reference values in human serum by high performance liquid chromatography. Journal of Lipid Research. https://doi.org/10.1016/s0022-2275(20)38042-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.