Endothelium-derived relaxing factor and nitric oxide possess identical pharmacologic properties as relaxants of bovine arterial and venous smooth muscle.
The DOI matches its Crossref record.
Abstract
The principal objective of this study was to compare and contrast the vascular smooth muscle-relaxing properties of endothelium-derived relaxing factor (EDRF) and nitric oxide (NO) in two different assay systems. In one system, precontracted rings of bovine intrapulmonary artery and vein and coronary artery were used to compare the relaxant effects of endothelium-dependent vasodilators, NO, S-nitroso-N-acetylpenicillamine, glyceryl trinitrate, prostacyclin and isoproterenol. In a second system, a bioassay superfusion cascade procedure was employed to compare the relaxant effects and biologic stability of EDRF and NO. Acetylcholine and bradykinin elicited concentration-dependent but transient relaxant responses in arterial and venous rings, respectively. NO and S-nitroso-N-acetylpenicillamine, which generates NO in solution, elicited similar transient relaxant responses in endothelium-denuded arterial and venous rings. Glyceryl trinitrate, however, produced sustained relaxations, as did isoproterenol and prostacyclin. Utilizing a bioassay superfusion cascade system in which intact perfused artery or vein was the source of EDRF and three endothelium-denuded arterial or venous strips mounted in series served as the detector of EDRF or NO, the relaxation profile and biologic stability of superfused EDRF were compared with those of superfused NO. Arterial or venous perfusion with acetylcholine or bradykinin, respectively, and superfusion of NO over the strips produced characteristic decremental relaxant responses in the three vascular strips and revealed the highly unstable nature of EDRF and NO (T1/2 = 3-5 sec for both). The relaxation profile of EDRF was indistinguishable from that of NO.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biosynthesis and Metabolism of Endothelium-Derived Nitric Oxide
Ignarro, L. J. (1990) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pa.30.040190.002535 · Cited by 1,314
Self-citationcGMP-Dependent Protein Kinases and cGMP Phosphodiesterases in Nitric Oxide and cGMP Action
Francis, S. H., Busch, J. L., & Corbin, J. D. (2010) · Pharmacological Reviews · doi:10.1124/pr.110.002907 · Cited by 1,028
The Endothelium and Its Role in Regulating Vascular Tone
Sandoo, A., Veldhuijzen van Zanten, J. J. C. S., Metsios, G. S., Carroll, D., & Kitas, G. D. (2010) · The Open Cardiovascular Medicine Journal · doi:10.2174/1874192401004010302 · Cited by 814
The chemistry of nitroxyl (HNO) and implications in biology
Miranda, K. M. (2005) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2004.08.010 · Cited by 339
Measurement of circulating nitrite and S-nitrosothiols by reductive chemiluminescence
MacArthur, P. H., Shiva, S., & Gladwin, M. T. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.012 · Cited by 231
Eiserich, J. P., Patel, R. P., & O’Donnell, V. B. (1998) · Molecular Aspects of Medicine · doi:10.1016/s0098-2997(99)00002-3 · Cited by 209
Impairment of vascular endothelial nitric oxide synthase activity by advanced glycation end products
Biao, X., Chibber, R., Ruggiero, D., Kohner, E., Ritter, J., & Ferro, A. (2003) · The FASEB Journal · doi:10.1096/fj.02-0490fje · Cited by 195
“ACh relaxes rabbit aorta by activating eNOS in the vascular endothelium, thereby generating NO, which relaxes the underlying vascular smooth muscle (55, 56).”
BackgroundMetal ion catalysis in nitrosothiol (RSNO) decomposition
McAninly, J., Williams, D. L. H., Askew, S. C., Butler, A. R., & Russell, C. (1993) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39930001758 · Cited by 150
Absence of Nitric-oxide Synthase in Sequentially Purified Rat Liver Mitochondria
Venkatakrishnan, P., Nakayasu, E. S., Almeida, I. C., & Miller, R. T. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.003301 · Cited by 52
Arginase activity in mitochondria – An interfering factor in nitric oxide synthase activity assays
Venkatakrishnan, P., Nakayasu, E. S., Almeida, I. C., & Miller, R. T. (2010) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2009.10.169 · Cited by 12
“Nitric Oxide (NO•) is a highly diffusible, hydrophobic gaseous free radical [2] that influences biological functions such as blood pressure, platelet aggregation/adhesion, neurotransmission as well as cellular defense [3;4;5;6;7;8;9].”
Background
Metadata
- Authors
- Ignarro, L. J., Buga, G. M., Byrns, R. E., Wood, K. S., & Chaudhuri, G.
- Venue
- The Journal of Pharmacology and Experimental Therapeutics
- Publisher
- Elsevier BV
- Published
- 1988-07
- Volume
- 246
- Issue
- 1
- Pages
- 218-226
- ISSN
- 0022-3565 (ISSN-L)
- OpenAlex
- W2310677230
- Cited by
- 93
- References
- 0
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.