Caffeine in plasma and saliva by a radioimmunoassay procedure.
The DOI matches its Crossref record.
Abstract
Caffeine was analyzed in human plasma and saliva by a simple, rapid, and sensitive radioimmunoassay procedure. Immunization of rabbits with an antigen prepared by coupling 7-(5-carboxypentyl)-1,3-dimethylxanthine to bovine serum albumin resulted in the formation of antibodies selective for caffeine as opposed to various mono- and dimethylxanthines, mono-, di-, and trimethyluric acids and a variety of common drugs. The radioligand used for competitive binding studies was 7-(2,3-3H2-propyl)-1,3-dimethylxanthine. The procedure permits direct analysis of caffeine in plasma or saliva without extraction. Comparison with a high pressure liquid chromatography method for the analysis of caffeine gave satisfactory results and showed no evidence for interference by metabolites. A caffeine half-life of 4.0 hours determined by the radioimmunoassay was in agreement with previous work. Comparison of human plasma and saliva levels by the radioimmunoassay procedure indicated approximately equal concentrations in the two fluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fredholm, B. B., Bättig, K., Holmén, J., Nehlig, A., & Zvartau, E. E. (1999) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01396-6 · Cited by 2,624
ANTI-ESCHERICHIA COLI ALPHA-HAEMOLYSIN IN CONTROL AND PATIENT SERA
Emody, L., Batai, I., Kerényi, M., Székely, J., & Polyak, L. (1982) · The Lancet · doi:10.1016/s0140-6736(82)90183-0 · Cited by 800
The Health Consequences of Caffeine
CURATOLO, P. W., & ROBERTSON, D. (1983) · Annals of Internal Medicine · doi:10.7326/0003-4819-98-5-641 · Cited by 271
Monteiro, J., Alves, M., Oliveira, P., & Silva, B. (2016) · Molecules · doi:10.3390/molecules21080974 · Cited by 182
“After the pre-treatment and extraction steps, a wide range of analytical techniques have been used for the analysis and quantification of the main methylxanthines including capillary gas chromatography (GC) [81], gas chromatography-mass spectrometry (GC-MS) [82,83], spectrophotometry [77,84–86], Fourier transform-Rama…”
MethodMenstrual cycle effects on caffeine elimination in the human female
Lane, J. D., Steege, J. F., Rupp, S. L., & Kuhn, C. M. (1992) · European Journal of Clinical Pharmacology · doi:10.1007/bf02285099 · Cited by 170
Metadata
- Authors
- Cook, C. E., Tallent, C. R., Amerson, E. W., Myers, M. W., Kepler, J. A., Taylor, G. F., & Christensen, H. D.
- Venue
- The Journal of Pharmacology and Experimental Therapeutics
- Publisher
- Elsevier BV
- Published
- 1976-12
- Volume
- 199
- Issue
- 3
- Pages
- 679-686
- ISSN
- 0022-3565 (ISSN-L)
- OpenAlex
- W2263477269
- Cited by
- 80
- References
- 0
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Caffeine in plasma and saliva by a radioimmunoassay procedure. https://app.cochat.ai/papers/10.1016/s0022-3565(25)30729-9
- The paper
- Cook, C. E., Tallent, C. R., Amerson, E. W., Myers, M. W., Kepler, J. A., Taylor, G. F., & Christensen, H. D. (1976). Caffeine in plasma and saliva by a radioimmunoassay procedure. The Journal of Pharmacology and Experimental Therapeutics. https://doi.org/10.1016/s0022-3565(25)30729-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.