Current ceramic materials and systems with clinical recommendations: A systematic review
The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zirconia as a ceramic biomaterial
Piconi, C., & Maccauro, G. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00010-6 · Cited by 2,806
GARVIE, R. C., HANNINK, R. H., & PASCOE, R. T. (1975) · Nature · doi:10.1038/258703a0 · Cited by 2,291
Phase Analysis in Zirconia Systems
Garvie, R. C., & Nicholson, P. S. (1972) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1972.tb11290.x · Cited by 1,614
The estimation of cement film thickness by an in vivo technique
McLean, J. W., & von, F. (1971) · British Dental Journal · doi:10.1038/sj.bdj.4802708 · Cited by 1,383
Kosmač, T., Oblak, C., Jevnikar, P., Funduk, N., & Marion, L. (1999) · Dental Materials · doi:10.1016/s0109-5641(99)00070-6 · Cited by 818
Considerations in measurement of marginal fit
Holmes, J. R., Bayne, S. C., Holland, G. A., & Sulik, W. D. (1989) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90170-4 · Cited by 769
Porcelain veneers: a review of the literature
Peumans, M., Van Meerbeek, B., Lambrechts, P., & Vanherle, G. (2000) · Journal of Dentistry · doi:10.1016/s0300-5712(99)00066-4 · Cited by 614
Clinical complications in fixed prosthodontics
Goodacre, C. J., Bernal, G., Rungcharassaeng, K., & Kan, J. Y. K. (2003) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(03)00214-2 · Cited by 588
Relative translucency of six all-ceramic systems. Part I: Core materials
Heffernan, M. (2002) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(02)00040-9 · Cited by 572
Tooth structure removal associated with various preparation designs for anterior teeth
Edelhoff, D., & Sorensen, J. A. (2002) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2002.124094 · Cited by 522
Raigrodski, A. J., Chiche, G. J., Potiket, N., Hochstedler, J. L., Mohamed, S. E., Billiot, S., & Mercante, D. E. (2006) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2006.08.010 · Cited by 502
Raigrodski, A. J. (2004) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2004.09.015 · Cited by 493
Relative translucency of six all-ceramic systems. Part II: Core and veneer materials
Heffernan, M. (2002) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(02)00041-0 · Cited by 432
Marginal fit of gold inlay castings
Christensen, G. J. (1966) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(66)90082-5 · Cited by 428
Tinschert, J., Natt, G., Mautsch, W., Augthun, M., & Spiekermann, H. (2001) · PubMed · Cited by 411
DeLong, R., & Douglas, W. H. (1983) · Journal of Dental Research · doi:10.1177/00220345830620010801 · Cited by 370
Reich, S., Wichmann, M. G., Nkenke, E., & Proeschel, P. (2005) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2004.00197.x · Cited by 364
Marginal and internal fit of all‐ceramic CAD/CAM crown‐copings on chamfer preparations
BINDL, A., & MÖRMANN, W. H. (2005) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2005.01446.x · Cited by 363
Damage accumulation and fatigue life of particle-abraded ceramics.
Zhang, Y., Lawn, B. R., Malament, K. A., Thompson, V. P., & Rekow, E. D. (2006) · PubMed · Cited by 328
VON STEYERN, P. V., CARLSON, P., & NILNER, K. (2005) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2004.01437.x · Cited by 322
Sundh, A., Molin, M., & Sjögren, G. (2005) · Dental Materials · doi:10.1016/j.dental.2004.07.013 · Cited by 288
Clinical fit of Procera AllCeram crowns
Boening, K. W., Wolf, B. H., Schmidt, A. E., Kästner, K., & Walter, M. H. (2000) · Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.109125 · Cited by 286
Tooth structure removal associated with various preparation designs for posterior teeth.
Edelhoff, D., & Sorensen, J. A. (2002) · PubMed · Cited by 273
Current status of luting agents for fixed prosthodontics
Diaz-Arnold, A. M., Vargas, M. A., & Haselton, D. R. (1999) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(99)70240-4 · Cited by 272
A new all-ceramic crown: A dense-sintered, high-purity alumina coping with porcelain
Andersson, M., & Odén, A. (1993) · Acta Odontologica Scandinavica · doi:10.3109/00016359309041149 · Cited by 268
Meta-analysis of fixed partial denture survival: Prostheses and abutments
Scurria, M. S., Bader, J. D., & Shugars, D. A. (1998) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70162-3 · Cited by 262
Five-year clinical evaluation of Procera AllCeram crowns
Odén, A., Andersson, M., Krystek-Ondracek, I., & Magnusson, D. (1998) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70010-1 · Cited by 234
Otto, T., & Nisco, S. D. (2002) · PubMed · Cited by 201
Fracture toughness of dental ceramics: comparison of bending and indentation method
Fischer, H. (2002) · Dental Materials · doi:10.1016/s0109-5641(01)00005-7 · Cited by 189
de Jager, N., Pallav, P., & Feilzer, A. J. (2005) · Dental Materials · doi:10.1016/j.dental.2004.03.013 · Cited by 185
Malament, K. A., Socransky, S. S., Malament, K. A., & Socransky, S. S. (1999) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(99)70231-3 · Cited by 183
Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
Oh, W.-S., & Anusavice, K. J. (2002) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2002.123850 · Cited by 170
Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study.
Ödman, P., & Andersson, B. (2001) · PubMed · Cited by 168
Sjögren, G., Molin, M., & van Dijken, J. W. V. (2004) · PubMed · Cited by 168
Biomechanical Compatibility and Design of Ceramic Implants for Orthopedic Surgery
CHRISTEL, P., MEUNIER, A., DORLOT, J. ‐., CROLET, J. ‐., WITVOET, J., SEDEL, L., & BOUTIN, P. (1988) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1988.tb38516.x · Cited by 168
Bindl, A., Richter, B., & Mörmann, W. (2005) · PubMed · Cited by 168
Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs.
Suárez, M. J., Lozano, J. F. L., Salido, M. P., & Martínez‐Rus, F. (2004) · PubMed · Cited by 165
Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures
Knoernschild, K. L., & Campbell, S. D. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.110262 · Cited by 162
Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems
Attia, A., & Kern, M. (2004) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2004.09.002 · Cited by 161
Virtual-Designed and Computer-Milled Implant Abutments
Priest, G. (2005) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2005.05.158 · Cited by 158
Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs.
von Steyern, P. V., Jönsson, O., & Nilner, K. (2001) · PubMed · Cited by 153
Clinical assessment of high-strength all-ceramic crowns
Haselton, D. R., Diaz-Arnold, A. M., & Hillis, S. L. (2000) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(00)70033-3 · Cited by 152
Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems
Balkaya, M. C., Cinar, A., & Pamuk, S. (2005) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2005.02.003 · Cited by 146
A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs.
Olsson, K.-G., Fürst, B., Andersson, B., & Carlsson, G. E. (2003) · PubMed · Cited by 138
Five-year follow-up with Procera all-ceramic crowns.
Fradeani, M., D'Amelio, M., Redemagni, M., & Corrado, M. (2005) · PubMed · Cited by 136
Sjögren, G., Lantto, R., Granberg, A., Sundström, B. O., & Tillberg, A. (1999) · PubMed · Cited by 132
Zirconia-TZP and alumina--advanced technologies for the manufacturing of single crowns.
Luthardt, R. G., Sandkuhl, O., & Reitz, B. (1999) · PubMed · Cited by 132
Contemporary all-ceramic fixed partial dentures: a review
Raigrodski, A. J. (2004) · Dental Clinics of North America · doi:10.1016/j.cden.2003.12.008 · Cited by 130
Denissen, H. W., Đozić, A., Zel, J. M. V. D., & van Waas, M. A. J. (2000) · Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.110258 · Cited by 129
Cyclic fatigue in water of veneer–framework composites for all-ceramic dental bridges
Studart, A. R., Filser, F., Kocher, P., Lüthy, H., & Gauckler, L. J. (2006) · Dental Materials · doi:10.1016/j.dental.2006.01.011 · Cited by 127
Influence of Connector Design on Fracture Probability of Ceramic Fixed-partial Dentures
Oh, W., Götzen, N., & Anusavice, K. J. (2002) · Journal of Dental Research · doi:10.1177/154405910208100909 · Cited by 125
Pallesen, U., & van Dijken, J. W. V. (2000) · European Journal Of Oral Sciences · doi:10.1034/j.1600-0722.2000.108003239.x · Cited by 123
Survival rate of mono‐ceramic and ceramic‐core CAD/CAM‐generated anterior crowns over 2–5 years
Bindl, A., & Mörmann, W. (2004) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2004.00119.x · Cited by 112
An up to 5-year clinical evaluation of posterior in-ceram CAD/CAM core crowns.
Bindl, A., & Mörmann, W. (2002) · PubMed · Cited by 103
Four year clinical study of glass‐infiltrated, sintered alumina crowns
Pröbster, L. (1996) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1996.tb01225.x · Cited by 103
The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature
Raigrodski, A. J., & Chiche, G. J. (2001) · Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.120111 · Cited by 102
Fracture resistance of different partial-coverage ceramic molar restorations
Stappert, C. F. J., Att, W., Gerds, T. A., & Strub, J. R. (2006) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2006.0224 · Cited by 101
Walton, T. (2003) · PubMed · Cited by 98
Properties of dual‐curable luting composites polymerized with single and dual curing modes
Tanoue, N., Koishi, Y., Atsuta, M., & Matsumura, H. (2003) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.2003.01074.x · Cited by 92
Wolfart, S., Bohlsen, F., Wegner, S. M., & Kern, M. (2005) · PubMed · Cited by 88
A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs
Olsson, K.-G., Fürst, B., Andersson, B., & Carlsson, G. E. (2003) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(03)00475-x · Cited by 78
Transverse fracture of brittle bilayers: Relevance to failure of all‐ceramic dental crowns
Kim, J., Bhowmick, S., Hermann, I., & Lawn, B. R. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30511 · Cited by 65
Framework Design in Ceramo-Metal Restorations
Miller, L. L. (1977) · Dental Clinics of North America · doi:10.1016/s0011-8532(22)00986-7 · Cited by 62
Clinical performance of large, all-ceramic CAD/CAM-generated restorations after three years
Reich, S., Wichmann, M. G., RINNE, H., & Shortall, A. C. C. (2004) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2004.0248 · Cited by 59
Five-Year Follow-up With Procera All-Ceramic Crowns
Mclntyre, F. M. (2006) · Yearbook of Dentistry · doi:10.1016/s0084-3717(08)70059-x · Cited by 59
Treatment of a single-tooth gap with a Cerec 3D crown on an implant: A case report.
Fritzsche, G. (2004) · PubMed · Cited by 10
Cited by
Advances in Biomaterials for Drug Delivery
Fenton, O. S., Olafson, K. N., Pillai, P. S., Mitchell, M. J., & Langer, R. (2018) · Advanced Materials · doi:10.1002/adma.201705328 · Cited by 855
Marginal adaptation of ceramic crowns: A systematic review
Contrepois, M., Soenen, A., Bartala, M., & Laviole, O. (2013) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.08.003 · Cited by 440
Sailer, I., Philipp, A., Zembic, A., Pjetursson, B. E., Hämmerle, C. H. F., & Zwahlen, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01787.x · Cited by 368
Advanced ceramic components: Materials, fabrication, and applications
Ayode Otitoju, T., Ugochukwu Okoye, P., Chen, G., Li, Y., Onyeka Okoye, M., & Li, S. (2020) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.02.002 · Cited by 368
CAD/CAM systems available for the fabrication of crown and bridge restorations
Miyazaki, T., & Hotta, Y. (2011) · Australian Dental Journal · doi:10.1111/j.1834-7819.2010.01300.x · Cited by 310
Metadata
- Authors
- Conrad, H. J., Seong, W.-J., & Pesun, I. J.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2007-11
- Volume
- 98
- Issue
- 5
- Pages
- 389-404
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W2091218805
- Cited by
- 981
- References
- 66
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.