Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 191

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization

Open access
Gorman, Joseph H., Gupta, Krishanu B., Streicher, James T., Gorman, Robert C., Jackson, Benjamin M., Ratcliffe, Mark B., Bogen, Daniel K., Edmunds, L.Henry · 1996 · The Journal of Thoracic and Cardiovascular Surgery

Abstract

OBJECTIVES: The first objective was to develop a quantitative method for tracking the three-dimensional geometry of the mitral valve. The second was to determine the complex interrelationships of various components of the mitral valve in vivo. METHODS AND RESULTS: Sixteen sonomicrometry transducers were placed around the mitral vale anulus, at the tips and bases of both papillary muscles, at the ventricular apex, across the ventricular epicardial short axis, and on the anterior chest wall before and during cardiopulmonary bypass in eight anesthetized sheep. Animals were studied later on 17 occasions. Reproducibility of derived chord lengths and three-dimensional coordinates from sonomicrometry array localization, longevity of transducer signals, and the dynamics of the mitral valve and left ventricle were studied. Reproducibility of distance measurements averages 1.6%; Procrustes analysis of three-dimensional arrays of coordinate locations predicts an average error of 2.2 mm. Duration of serial sonomicrometry array localization signals ranges between 60 and 151 days (mean 114 days). Sonomicrometry array localization demonstrates the saddle-shaped mitral anulus, its minimal orifice area immediately before end-diastole, and uneven, apical descent during systole. Papillary muscles shorten only 3.0 to 3.5 mm. Sonomicrometry array localization demonstrates nonuniform torsion of papillary muscle transducers around a longitudinal axis and shows rotation of papillary muscular bases toward each other during systole. CONCLUSION: Tagging of ventricular structures in experimental animals by sonomicrometry array localization images is highly reproducible and suitable for serial observations. In sheep the method provides unique, quantitative information regarding the interrelationship of mitral valvular and left ventricular structures throughout the cardiac cycle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5223(96)70056-9

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 191

Metadata

Authors
Gorman, J. H., Gupta, K. B., Streicher, J. T., Gorman, R. C., Jackson, B. M., Ratcliffe, M. B., Bogen, D. K., & Edmunds, L. H.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
1996-09
Volume
112
Issue
3
Pages
712-724
ISSN
0022-5223 (ISSN-L)
OpenAlex
W1986185736
Cited by
191
References
1
FWCI
1.45
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization. https://app.cochat.ai/papers/10.1016/s0022-5223(96)70056-9
The paper
Gorman, J. H., Gupta, K. B., Streicher, J. T., Gorman, R. C., Jackson, B. M., Ratcliffe, M. B., Bogen, D. K., & Edmunds, L. H. (1996). Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/s0022-5223(96)70056-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.