Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Left ventricular assist devices have provided successful supportive therapy for patients awaiting cardiac transplantation for extended periods of time. Although thromboembolic events have complicated support with these devices, the HeartMate left ventricular assist device developed by Thermo Cardiosystems, Inc., Woburn, Massachusetts, was specifically designed with a textured blood-contacting surface to minimize this risk. Clinical experience with this device has been encouraging, inasmuch as minimal thromboembolic complications have occurred despite the absence of anticoagulation. The coagulation and fibrinolytic pathways in these individuals were investigated to better understand the hematologic status of patients treated with the Thermo Cardiosystems device. Despite apparently normal prothrombin and activated partial thromboplastin times, as well as platelet counts, evidence of significant thrombin generation and fibrinolysis was present. To eliminate underlying cardiac failure as the responsible factor for these abnormalities, we made similar measurements in patients with end-stage heart failure who were not supported by an assist device or anticoagulation. These measurements revealed no evidence of thrombin generation or fibrinolysis. These data demonstrate that patients supported with a left ventricular assist device, while successfully sustained without systemic anticoagulation, nevertheless have evidence of activation of coagulation. These phenomena appear to be related to the presence of the device rather than to the underlying cardiac abnormalities. Although procoagulant and fibrinolytic pathways are apparently balanced in these patients, these data underscore the potential for the development of bleeding or thrombosis in clinically relevant settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of Ranks in One-Criterion Variance Analysis
Kruskal, W. H., & Wallis, W. A. (1952) · Journal of the American Statistical Association · doi:10.1080/01621459.1952.10483441 · Cited by 13,912
Practical Nonparametric Statistics
Groggel, D. J. (2000) · Technometrics · doi:10.1080/00401706.2000.10486067 · Cited by 11,041
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
The Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982050 · Cited by 3,261
Practical Non-Parametric Statistics.
Brown, B. M., & Conover, W. J. (1981) · Biometrics · doi:10.2307/2530578 · Cited by 2,394
Teitel, J., Bauer, K., Lau, H., & Rosenberg, R. (1982) · Blood · doi:10.1182/blood.v59.5.1086.1086 · Cited by 264
Rafii, S., Öz, M. C., Seldomridge, J. A., Ferris, B., Asch, A. S., Nachman, R. L., Shapiro, F., Rose, E. A., & Levin, H. R. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00807-1 · Cited by 117
Self-citationFrazier, O. H., Baldwin, R. T., Eskin, S. G., & Duncan, J. M. (1993) · PubMed Central · Cited by 75
Evaluation of bioprosthetic valve-associated thrombus in ventricular assist device patients.
Wagner, W. R., Johnson, P. C., Kormos, R. L., et al. (1993) · Circulation · doi:10.1161/01.cir.88.5.2023 · Cited by 57
Yaqoob, M. M., Patrick, A. W., McClelland, P. D., Stevenson, A., Mason, H. J., White, M. C., & Bell, G. M. (1993) · Clinical Science · doi:10.1042/cs0850557 · Cited by 53
Menconi, M. J., Pockwinse, S. M., Owen, T. A., Dasse, K. A., Stein, G. S., & Lian, J. B. (1995) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240570320 · Cited by 45
Cited by
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
Self-citationImplantable Left Ventricular Assist Devices
Goldstein, D. J., Oz, M. C., & Rose, E. A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199811193392107 · Cited by 492
Self-citationAnkersmit, H. J., Tugudea, S., Spanier, T., Weinberg, A. D., Artrip, J. H., Burke, E. M., Flannery, M., Mancini, D., Rose, E. A., Edwards, N. M., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10359-8 · Cited by 194
Self-citation
Metadata
- Authors
- Spanier, T., Oz, M., Levin, H., Weinberg, A., Stamatis, K., Stern, D., Rose, E., & Schmidt, A. M.
- Venue
- The Journal of Thoracic and Cardiovascular Surgery
- Publisher
- Elsevier BV
- Published
- 1996-10
- Volume
- 112
- Issue
- 4
- Pages
- 1090-1097
- ISSN
- 0022-5223 (ISSN-L)
- OpenAlex
- W2093436954
- Cited by
- 158
- References
- 11
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.