Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass

Open access
Gorman, Robert C., Ziats, Nicholas P., Rao, A.Koneti, Gikakis, Nicolas, Sun, Ling, Khan, Mohammed M.H., Stenach, Nina, Sapatnekar, Suneeti, Chouhan, Vibhuti, Gorman, Joseph H., Niewiarowski, Stefan, Colman, Robert W., Anderson, James M., Edmunds, L.Henry · 1996 · The Journal of Thoracic and Cardiovascular Surgery
Cited by 144

The DOI matches its Crossref record.

Abstract

The hypothesis that heparin-coated perfusion circuits reduce thrombin formation and activity; fibrinolysis; and platelet, complement, and neutrophil activation was tested in 20 consecutive, randomized adults who had cardiopulmonary bypass. Twenty identical perfusion systems were used; in 10, all blood-contacting surfaces were coated with partially degraded heparin (Carmeda process; Medtronic Cardiopulmonary, Anaheim, Calif.). All patients received a 300 U/kg dose of heparin. Activated clotting times were maintained longer than 400 seconds. Cardiopulmonary bypass lasted 36 to 244 minutes. Blood samples for platelet count, platelet response to adenosine diphosphate, plasma beta-thromboglobulin, inactivated complement 3b, neutrophil elastase, fibrinopeptide A, prothrombin fragment F1.2, thrombin-antithrombin complex, tissue plasminogen activator, plasminogen activator inhibitor-1, plasmin alpha 2-antiplasmin complex, and D-dimer were obtained at these times: after heparin was given, 5 and 30 minutes after cardiopulmonary bypass was started, within 5 minutes after bypass was stopped, and 15 minutes after protamine was given. After cardiopulmonary bypass, tubing segments were analyzed for surface-adsorbed anti-thrombin, fibrinogen, factor XII, and von Willebrand factor by radioimmunoassay. Heparin-coated circuits significantly (p < 0.001) reduced platelet adhesion and maintained platelet sensitivity to adenosine diphosphate (p = 0.015), but did not reduce release of beta-thromboglobulin. There were no significant differences between groups at any time for fibrinopeptide A, prothrombin fragment F1.2, or thrombin-antithrombin complex or in the markers for fibrinolysis: D-dimer, tissue plasminogen activator, plasminogen activator inhibitor-1, and alpha 2-antiplasmin complex. In both groups, concentrations of prothrombin fragment F1.2 and thrombin-antithrombin complex increased progressively and significantly during cardiopulmonary bypass and after protamine was given. Concentrations of D-dimer, alpha 2-antiplasmin complex, and plasminogen activator inhibitor-1 also increased significantly during bypass in both groups. Fibrinopeptide A levels did not increase during bypass but in both groups increased significantly after protamine was given. No significant differences were observed between groups for levels of inactivated complement 3b or neutrophil elastase. Radioimmunoassay showed a significant increase in surface-adsorbed antithrombin on coated circuits but no significant differences between groups for other proteins. We conclude that heparin-coated circuits used with standard doses of systemic heparin reduce platelet adhesion and improve platelet function but do not produce a meaningful anticoagulant effect during clinical cardiopulmonary bypass. The data do not support the practice of reducing systemic heparin doses during cardiac operations with heparin-coated extracorporeal perfusion circuitry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5223(96)70395-1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 144

Metadata

Authors
Gorman, R. C., Ziats, N. P., Rao, A. K., Gikakis, N., Sun, L., Khan, M. M. H., Stenach, N., Sapatnekar, S., Chouhan, V., Gorman, J. H., Niewiarowski, S., Colman, R. W., Anderson, J. M., & Edmunds, L. H.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
1996-01
Volume
111
Issue
1
Pages
1-12
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2088203721
Cited by
144
References
0
FWCI
17.92
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass. https://app.cochat.ai/papers/10.1016/s0022-5223(96)70395-1
The paper
Gorman, R. C., Ziats, N. P., Rao, A. K., Gikakis, N., Sun, L., Khan, M. M. H., Stenach, N., Sapatnekar, S., Chouhan, V., Gorman, J. H., Niewiarowski, S., Colman, R. W., Anderson, J. M., & Edmunds, L. H. (1996). Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/s0022-5223(96)70395-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.