The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Limitations to significant information in biological electron microscopy as a result of radiation damage
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstruction of Three Dimensional Structures from Electron Micrographs
DE ROSIER, D. J., & KLUG, A. (1968) · Nature · doi:10.1038/217130a0 · Cited by 1,345
Methods for the enhancement of image detail and accentuation of structure in electron microscopy
Markham, R., Frey, S., & Hills, G. J. (1963) · Virology · doi:10.1016/0042-6822(63)90143-0 · Cited by 569
The lattice spacing of crystalline catalase as an internal standard of length in electron microscopy
Wrigley, N. G. (1968) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(68)80048-6 · Cited by 424
Current Topics in Radiation Research
Elkind, M. M. (1968) · Radiology · doi:10.1148/91.4.831b · Cited by 373
CROWTHER, R. A., AMOS, L. A., FINCH, J. T., DE ROSIER, D. J., & KLUG, A. (1970) · Nature · doi:10.1038/226421a0 · Cited by 346
Positron-Electron Differences in Energy Loss and Multiple Scattering
Rohrlich, F., & Carlson, B. C. (1954) · Physical Review · doi:10.1103/physrev.93.38 · Cited by 268
Electron microscopy of tobacco mosaic virus under conditions of minimal beam exposure
Williams, R. C., & Fisher, H. W. (1970) · Journal of Molecular Biology · doi:10.1016/0022-2836(70)90181-6 · Cited by 254
Johnson, H. M., & Parsons, D. F. (1969) · Journal of Microscopy · doi:10.1111/j.1365-2818.1969.tb00708.x · Cited by 24
Electron Microscopy of Polyethylene below 20° K
Venables, J. A., & Bassett, D. C. (1967) · Nature · doi:10.1038/2141107a0 · Cited by 12
Cited by
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
EMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
Grant, T., & Grigorieff, N. (2015) · eLife · doi:10.7554/elife.06980 · Cited by 826
Soft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Metadata
- Authors
- Glaeser, R. M.
- Venue
- Journal of Ultrastructure Research
- Publisher
- Elsevier BV
- Published
- 1971-08
- Volume
- 36
- Issue
- 3-4
- Pages
- 466-482
- ISSN
- 0022-5320 (ISSN-L)
- OpenAlex
- W2005601437
- Cited by
- 380
- References
- 9
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations to significant information in biological electron microscopy as a result of radiation damage. https://app.cochat.ai/papers/10.1016/s0022-5320(71)80118-1
- The paper
- Glaeser, R. M. (1971). Limitations to significant information in biological electron microscopy as a result of radiation damage. Journal of Ultrastructure Research. https://doi.org/10.1016/s0022-5320(71)80118-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.