Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; its reference list is not available.

New surgical technique for sphincter urinary control system using upper transverse scrotal incision.

Abstract

Purpose Traditional implantation of the AMS Sphincter 800 Urinary Control System (American Medical Systems, Minnetonka, Minnesota) requires 2 incisions. The cuff is placed via a perineal incision, and the pressure regulating balloon and pump are placed through a separate suprapubic incision. We describe a novel implantation of all the artificial urinary sphincter components using a single upper scrotal incision. The scrotal incision allows excellent access to the proximal bulbar urethra and retropubic and subdartos spaces, and leaves the bulbocavernosus muscle intact. Materials and methods A total of 37 patients have undergone artificial urinary sphincter implantation using the new operative technique for revisions or reimplantations of a sphincter previously removed for infection/erosion (12) or as an initial procedure (25). In 9 of the 25 patients and 2 of the 12 dual implantation of a 3-piece penile prosthesis through the same incision was performed. Results All patients are using the devices. Of the patients 66% are completely dry with no pad use and the remainder use 1 pad for accident prevention. Operative time was reduced due to easier exposure of the urethra and a second incision for placement of the pressure regulating balloon was not necessary. Followup at 1 year shows no difference in complication rate with the single incision technique compared to the traditional method. Conclusions Artificial urinary sphincter implantation through a single scrotal incision is eas…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(05)64082-7

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 10 · Cited by 140

Research works printed but not linked: 12

  1. Wilson, 2001, A new approach for implantation of artificial urinary sphincter: upper transverse scrotal incision, J Urol, 165, 256
  2. Montague, 2000, Postprostatectomy urinary incontinenaaa the case for artificial urinary sphincter implantation, Urology, 55, 2, 10.1016/S0090-4295(99)00413-6 · doi:10.1016/s0090-4295(99)00413-6
  3. Gousse, 2001, Artificial urinary sphincter for post-radical prostatectomy urinary incontinenaaa long-term subjective results, J Urol, 166, 1755, 10.1016/S0022-5347(05)65668-6 · doi:10.1016/s0022-5347(05)65668-6
  4. Fishman, 1989, Experience with the artificial urinary sphincter model AS800 in 148 patients, J Urol, 141, 307, 10.1016/S0022-5347(17)40748-8 · doi:10.1016/s0022-5347(17)40748-8
  5. Brito, 1993, Use of a double cuff AMS800 urinary sphincter for severe stress incontinence, J Urol, 149, 283, 10.1016/S0022-5347(17)36057-3 · doi:10.1016/s0022-5347(17)36057-3
  6. Guralnick, 2002, Transcorporal artificial urinary sphincter cuff placement in cases requiring revision for erosion and urethral atrophy, J Urol, 167, 2075, 10.1016/S0022-5347(05)65088-4 · doi:10.1016/s0022-5347(05)65088-4
  7. Sadeghi-Nejad, 2001, Reservoir herniation as a complication of three-piece penile prosthesis insertion, Urology, 57, 142, 10.1016/S0090-4295(00)00864-5 · doi:10.1016/s0090-4295(00)00864-5
  8. Stone, 2001, Editorial comment, J Urol, 166, 1375, 10.1016/S0022-5347(01)69517-X · doi:10.1016/s0022-5347(01)69517-x
  9. Venn, 2000, The long-term outcome of artificial urinary sphincters, J Urol, 164, 702, 10.1016/S0022-5347(05)67285-0 · doi:10.1016/s0022-5347(05)67285-0
  10. Clemens, 2001, Revision rate after artificial urinary sphincter implantation for incontinence after radical prostatectomy: actuarial analysis, J Urol, 166, 1372, 10.1016/S0022-5347(05)65772-2 · doi:10.1016/s0022-5347(05)65772-2
  11. Montague, 2001, Editorial comment, J Urol, 166, 1375, 10.1016/S0022-5347(01)69517-X · doi:10.1016/s0022-5347(01)69517-x
  12. Diokno, 2000, Editorial comment, J Urol, 164, 706, 10.1016/S0022-5347(01)69697-6 · doi:10.1016/s0022-5347(01)69697-6

Metadata

Authors
WILSON, S. K., DELK, J. R., HENRY, G. D., & SIEGEL, A. L.
Affiliations
Hackensack University Medical Center (US)
Venue
Journal of Urology
Published
2003-01
Volume
169
Issue
1
Pages
261-264
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W4322703104
Cited by
140
References
10
Citations by year
2026: 2 · 2025: 5 · 2024: 7 · 2023: 4 · 2022: 5 · 2021: 1 · 2020: 10 · 2019: 5 · 2018: 5 · 2017: 8 · 2016: 9 · 2015: 4 · 2014: 10 · 2013: 4 · 2012: 10
FWCI
2.61
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
The Journal of Urology (publishedVersion)
Topics
  • Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
  • Health Sciences › Medicine › Urology › Urological Disorders and Treatments
  • Health Sciences › Medicine › Urology › Pelvic floor disorders treatments
Keywords
artificial urinary sphincter, urinary incontinence, pressure regulating balloon, bulbocavernosus muscle, surgical technique, postoperative complications, bulbar urethra

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New surgical technique for sphincter urinary control system using upper transverse scrotal incision. https://app.cochat.ai/papers/10.1016/s0022-5347(05)64082-7
The paper
WILSON, S. K., DELK, J. R., HENRY, G. D., & SIEGEL, A. L. (2003). New surgical technique for sphincter urinary control system using upper transverse scrotal incision. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)64082-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.