The DOI matches its Crossref record.
Efficacy and Safety of Transdermal Oxybutynin in Patients With Urge and Mixed Urinary Incontinence
Abstract
PURPOSE: We evaluated the efficacy and safety of an oxybutynin transdermal delivery system (TDS) in a general population of patients with overactive bladder and urge or mixed urinary incontinence. MATERIALS AND METHODS: Following symptom stabilization or treatment withdrawal 520 adult patients were randomized to 12 weeks of double-blind daily treatment with 1.3, 2.6 or 3.9 mg. oxybutynin TDS or placebo administered twice weekly, followed by a 12-week open-label, dose titration period to assess efficacy and safety further. Evaluations included patient urinary diaries, incontinence specific quality of life and safety. RESULTS: A dose of 3.9 mg. daily oxybutynin TDS significantly reduced the number of weekly incontinence episodes (median change -19.0 versus -14.5, p = 0.0165), reduced average daily urinary frequency (mean change -2.3 versus -1.7, p = 0.0457), increased average voided volume (median change 24 versus 6 ml., p = 0.0063) and significantly improved quality of life (Incontinence Impact Questionnaire total score, p = 0.0327) compared with placebo. Average voided volume increased in the daily 2.6 mg. group (19 ml., p = 0.0157) but there were no other significant differences between 1.3 and 2.6 mg. oxybutynin TDS and placebo. The most common adverse event was application site pruritus (oxybutynin TDS 10.8% to 16.8%, placebo 6.1%). Dry mouth incidence was similar in both groups (7.0% versus 8.3%, p not significant). In the open-label period a sustained reduction of nearly 3 incontinence episodes per day was reported for all groups. CONCLUSIONS: Doses of 2.6 and 3.9 mg. oxybutynin TDS daily improve overactive bladder symptoms and quality of life, and are well tolerated. Transdermal oxybutynin is an innovative new treatment for overactive bladder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chapple, C. R., Khullar, V., Gabriel, Z., Muston, D., Bitoun, C. E., & Weinstein, D. (2008) · European Urology · doi:10.1016/j.eururo.2008.06.047 · Cited by 769
Diagnosis and Treatment of Overactive Bladder (Non-Neurogenic) in Adults: AUA/SUFU Guideline
Gormley, E. A., Lightner, D. J., Burgio, K. L., Chai, T. C., Clemens, J. Q., Culkin, D. J., Das, A. K., Foster, H. E., Scarpero, H. M., Tessier, C. D., et al. (2012) · Journal of Urology · doi:10.1016/j.juro.2012.09.079 · Cited by 710
Norton, P., & Brubaker, L. (2006) · The Lancet · doi:10.1016/s0140-6736(06)67925-7 · Cited by 579
Management of Overactive Bladder
Ouslander, J. G. (2004) · New England Journal of Medicine · doi:10.1056/nejmra032662 · Cited by 411
Muscarinic receptor antagonists for overactive bladder
Abrams, P., & Andersson, K. (2007) · BJU International · doi:10.1111/j.1464-410x.2007.07205.x · Cited by 405
Metadata
- Authors
- Dmochowski, R. R., Davila, G. W., Zinner, N. R., Gittelman, M. C., Saltzstein, D. R., Lyttle, S., Sanders, S. W., & for THE TRANSDERMAL OXYBUTYNIN STUDY GROUP
- Venue
- Journal of Urology
- Published
- 2002-08
- Volume
- 168
- Issue
- 2
- Pages
- 580-586
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W1994653403
- Cited by
- 213
- References
- 0
- FWCI
- 17.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy and Safety of Transdermal Oxybutynin in Patients With Urge and Mixed Urinary Incontinence. https://app.cochat.ai/papers/10.1016/s0022-5347(05)64684-8
- The paper
- Dmochowski, R. R., Davila, G. W., Zinner, N. R., Gittelman, M. C., Saltzstein, D. R., Lyttle, S., Sanders, S. W., & for THE TRANSDERMAL OXYBUTYNIN STUDY GROUP. (2002). Efficacy and Safety of Transdermal Oxybutynin in Patients With Urge and Mixed Urinary Incontinence. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)64684-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.