Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record.

DIFFERENCES IN BLADDER COMPLIANCE WITH TIME AND ASSOCIATIONS OF BLADDER MANAGEMENT WITH COMPLIANCE IN SPINAL CORD INJURED PATIENTS

WELD, KYLE J., GRANEY, MARSHALL J., DMOCHOWSKI, ROGER R. · 2000 · Journal of Urology

Abstract

PURPOSE: Controversy continues on the optimal method of bladder management in spinal cord injured patients. We investigated the effects of bladder management on bladder compliance and changes in compliance with time. MATERIALS AND METHODS: We retrospectively reviewed the charts, and video urodynamic and upper tract radiographic studies of 316 patients with spinal cord injury. Patients were categorized according to interval since injury and bladder management method, including clean intermittent catheterization, spontaneous voiding and chronic Foley catheterization. Those with upper tract complications were compared with asymptomatic controls at the bladder compliance threshold values of 10.0, 12.5, 15.0 and 20.0 cc/cm. water. RESULTS: No significant differences were noted among bladder management method groups for followup, level, completeness or mechanism of injury. A bladder compliance threshold of 12.5 cc/cm. water was selected for the remaining comparisons based on the frequency of complications compared with asymptomatic controls. Patients using intermittent catheterization had a significantly higher incidence of normal compliance than the Foley management group for suprasacral, complete and incomplete injury (p<0.01). Normal bladder compliance was more common in patients with suprasacral than sacral and incomplete than complete spinal cord injury for each bladder management type. Logistic regression analysis of compliance versus bladder management and age of injury (interval since injury) revealed that intermittent catheterization and spontaneous voiding were associated more with normal compliance than Foley catheterization (RR = 9.2, 5.4 and 1.0, respectively). Combined data showed that each successively older age of injury cohort was at 23% greater risk for loss of normal compliance than the preceding cohort. Low compliance was statistically associated with vesicoureteral reflux, radiographic upper tract abnormality, pyelonephritis and upper tract stones (p<0.01, <0.01, 0.04 and <0.01, respectively). CONCLUSIONS: Clean intermittent catheterization protects bladder compliance in spinal cord injured patients regardless of the level or completeness of injury and helps to prevent low compliance with time. Also, in the population studied low compliance was associated with upper tract complications. Therefore, clean intermittent catheterization is the superior method for preserving bladder compliance and preventing the upper tract complications associated with low compliance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(05)67730-0

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 187

Metadata

Authors
WELD, K. J., GRANEY, M. J., & DMOCHOWSKI, R. R.
Venue
Journal of Urology
Published
2000-04
Volume
163
Issue
4
Pages
1228-1233
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2090339143
Cited by
187
References
0
FWCI
3.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: DIFFERENCES IN BLADDER COMPLIANCE WITH TIME AND ASSOCIATIONS OF BLADDER MANAGEMENT WITH COMPLIANCE IN SPINAL CORD INJURED PATIENTS. https://app.cochat.ai/papers/10.1016/s0022-5347(05)67730-0
The paper
WELD, K. J., GRANEY, M. J., & DMOCHOWSKI, R. R. (2000). DIFFERENCES IN BLADDER COMPLIANCE WITH TIME AND ASSOCIATIONS OF BLADDER MANAGEMENT WITH COMPLIANCE IN SPINAL CORD INJURED PATIENTS. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)67730-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.