CoChat

ASSESSMENT OF THE FUNCTIONAL ROLE OF ACCESSORY PUDENDAL ARTERIES IN ERECTION BY TRANSRECTAL COLOR DOPPLER ULTRASOUND

DROUPY, STÉPHANE, HESSEL, ANNE, BENOÎT, GÉRARD, BLANCHET, PASCAL, JARDIN, ALAIN, GIULIANO, FRANÇOIS · 1999 · Journal of Urology
Cited by 84

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: Anatomical studies have demonstrated accessory pudendal arteries originating from supralevator vessels in about two-thirds of men. Injury to accessory pudendal arteries derived from inferior vesical and obturator arteries has been reported to be responsible for vasculogenic impotence after nerve sparing radical prostatectomy. We performed transrectal and perineal color Doppler ultrasound in patients before radical pelvic surgery to identify accessory pudendal arteries and assess their functional role during erection. MATERIALS AND METHODS: A total of 12 patients with a mean age of 60 years were examined before radical prostatectomy (10) or cystoprostatectomy (2). Transrectal and perineal color Doppler flow imaging and spectral waveform analysis were performed. Peak systolic velocity, end diastolic velocity, resistive index and arterial diameter were measured before and during pharmacologically induced erection. Transrectal color Doppler ultrasound data were compared with intraoperative findings. RESULTS: Transrectal color Doppler ultrasound visualized accessory pudendal arteries derived from supralevator arteries in 9, and prostatic and seminal vesicle arteries in all patients. Perineal color Doppler ultrasound visualized internal pudendal arteries in all patients. After intracavernosal injection of papaverine accessory and internal pudendal arteries displayed similar significant hemodynamic changes. Diameter as well as peak systolic and end diastolic velocities increased, and resistive index decreased. Prostatic and seminal vesicle arteries showed no significant change. Presence and location of accessory pudendal arteries demonstrated by transrectal color Doppler ultrasound were confirmed by intraoperative findings. CONCLUSIONS: During pharmacologically induced erection hemodynamic changes in accessory and internal pudendal arteries are similar to those described in cavernous arteries, thus demonstrating the functional role of accessory pudendal arteries in penile erection. Color Doppler ultrasound appears to be reliable to examine internal and accessory pudendal arteries based on morphological and functional criteria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(05)68084-6

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 84

Metadata

Authors
DROUPY, S., HESSEL, A., BENOÎT, G., BLANCHET, P., JARDIN, A., & GIULIANO, F.
Venue
Journal of Urology
Published
1999-12
Volume
162
Issue
6
Pages
1987-1991
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2129137633
Cited by
84
References
3
FWCI
0.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.