The DOI matches its Crossref record.
Rate of Change in Serum Prostate Specific Antigen Levels as a Method For Prostate Cancer Detection
Abstract
To examine prospectively the usefulness of measurement of rate of change in serum prostate specific antigen levels (PSA slope) in detecting prostate cancer in a PSA-based prostate cancer screening study, we evaluated 982 serially screened men whose initial screening was negative for cancer. All men had at least 1 PSA value greater than 4.0 ng./ml. and all ultimately underwent prostatic biopsy. For those who entered the study with normal PSA levels, a PSA slope cutoff point of 0.75 ng./ml. per year or more maximized sensitivity and specificity for predicting cancer (odds ratio 7.20, 95% confidence interval 4.52 to 11.47). This cutoff point was most predictive for men 70 years old or younger. For men who entered the study with elevated PSA levels (greater than 4.0 ng./ml.) a lower PSA slope cutoff point (0.4 ng./ml. per year or more) maximized sensitivity and specificity for predicting cancer (odds ratio 2.73, 95% confidence interval 1.82 to 4.07). We conclude that PSA slope is useful for serial prostate cancer screening, although its predictive value varies with patient age and initial PSA level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Decline of Androgen Levels in Elderly Men and Its Clinical and Therapeutic Implications
Kaufman, J. M., & Vermeulen, A. (2005) · Endocrine Reviews · doi:10.1210/er.2004-0013 · Cited by 1,079
Catalona, W. J. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530150038031 · Cited by 679
Self-citationCarter, H. B., Ferrucci, L., Kettermann, A., Landis, P., Wright, E. J., Epstein, J. I., Trock, B. J., & Metter, E. J. (2006) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djj410 · Cited by 556
Screening for Prostate Cancer: An Update of the Evidence for the U.S. Preventive Services Task Force
Harris, R., & Lohr, K. N. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-11-200212030-00014 · Cited by 348
Catalona, W. J., Southwick, P. C., Slawin, K. M., Partin, A. W., Brawer, M. K., Flanigan, R. C., Patel, A., Richie, J. P., Walsh, P. C., Scardino, P. T., et al. (2000) · Urology · doi:10.1016/s0090-4295(00)00637-3 · Cited by 335
Self-citation
Metadata
- Authors
- Smith, D. S., & Catalona, W. J.
- Venue
- Journal of Urology
- Published
- 1994-10
- Volume
- 152
- Issue
- 4
- Pages
- 1163-1167
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W80256803
- Cited by
- 191
- References
- 0
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rate of Change in Serum Prostate Specific Antigen Levels as a Method For Prostate Cancer Detection. https://app.cochat.ai/papers/10.1016/s0022-5347(17)32528-4
- The paper
- Smith, D. S., & Catalona, W. J. (1994). Rate of Change in Serum Prostate Specific Antigen Levels as a Method For Prostate Cancer Detection. Journal of Urology. https://doi.org/10.1016/s0022-5347(17)32528-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.