Essential tremor – assessment of tremor accelerometric parameters' symmetry and the relationship between hand dominance and severity of tremor
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
Essential tremor (ET) is likely the most common movement disorder. The aim of the study was to carry out spectral analysis of the essential tremor recorded by an accelerometer and assess the symmetry of tremor parameters between the two hands. We examined 39 patients with ET diagnosed clinically using the criteria of the Movement Disorder Society. The control group consisted of 52 healthy persons. A biaxial accelerometer mounted at the dorsal side of the hand was used. Spectral analysis was performed. Tremor intensity, frequency of spectral peaks, centre frequency, standard deviation of the centre frequency, and harmonic index were measured. The side-to-side symmetry of these parameters was analysed. The relationship of hand dominance and severity of tremor was also analysed. There was significant side-to-side asymmetry of intensity in ET. The intensity in the more affected hand was over two times higher than that in the less affected one. The tremor was more severe in the nondominant hand in 62% of patients. In spite of significant difference in tremor intensity between the two sides, tremor frequency was similar in both hands. The standard deviation of centre frequency was significantly lower and the harmonic index was significantly higher in the more trembling hand. Accelerometric registration revealed that asymmetry of intensity and symmetry of frequency are characteristic features of ET. The remaining two coefficients reflecting the rhythmicity and regularity of tremor also differed considerably between the hands. Drżenie samoistne (DS) jest prawdopodobnie najczęściej występującym zaburzeniem ruchowym. Celem pracy była analiza widmowa zarejestrowanego drżenia samoistnego za pomocą akcelerometru z oceną symetrii badanych wskaźników pomiędzy rękami. Zbadano 39 chorych na DS rozpoznane na podstawie kryteriów Movement Disorders Society. Grupa kontrolna liczyła 52 zdrowe osoby. Użyto dwuosiowego akcelerometru, który umieszczano na części grzbietowej ręki. Dokonano analizy widmowej zapisu, oceniając: intensywność drżenia, częstotliwość wartości szczytowych w widmie, częstotliwość środkową, odchylenie standardowe od częstotliwości środkowej i indeks harmoniczny. Porównano wartości badanych parametrów z ręki o większej i mniejszej intensywności drżenia. Analizowano również związek dominacji ręki z nasileniem drżenia. U chorych na DS stwierdzono znamienną asymetrię intensywności pomiędzy obiema rękami. W ręce z bardziej nasilonym drżeniem intensywność była ponaddwukrotnie większa niż w drugiej ręce. U 62% chorych większą intensywność drżenia stwierdzono w ręce niedominującej. Pomimo znamiennych różnic w intensywności drżenia, częstotliwość była porównywalna w obu rękach. Odchylenie standardowe od częstotliwości środkowej było istotnie mniejsze, a indeks harmoniczny znamiennie większy w ręce o większym nasileniu drżenia. Badanie akcelerometryczne wykazało, że asymetria intensywności i symetria częstotliwości są charakterystycznymi cechami DS. Pozostałe dwa wskaźniki, które świadczą o rytmiczności i regularności drżenia, także różniły się znamiennie pomiędzy rękami.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It has been previously shown that the spectral analysis of accelerometer signals can effectively discriminate between ET and healthy controls [66].”
From Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor (2024) · cites this paper as [66]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 32 · Cited by 13
Research works printed but not linked: 1
- Yakovlev, 1966, Pattern of decussation of bulbar pyramids and distribution of pyramidal tracts on two sides of the spinal cord, Trans Am Neurol Assoc, 91, 366
Metadata
- Authors
- Machowska-Majchrzak, A., Pierzchała, K., Pietraszek, S., & Łabuz-Roszak, B.
- Affiliations
- Medical University of Silesia (PL)
- Corresponding author
- Machowska-Majchrzak, Agnieszka
- Venue
- Neurologia i Neurochirurgia Polska
- Publisher
- VM Media SP. zo.o VM Group SK
- Published
- 2011
- Volume
- 45
- Issue
- 2
- Pages
- 121-127
- ISSN
- 0028-3843 (ISSN-L)
- OpenAlex
- W1980689736
- Cited by
- 13
- References
- 32
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 1 · 2019: 2 · 2018: 1 · 2017: 1 · 2015: 1 · 2013: 2
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Neurologia i Neurochirurgia Polska (publishedVersion)
- PubMed (publishedVersion)
- Via Medica Journals (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Neurological and metabolic disorders
- Keywords
- essential tremor, handedness, tremor severity, tremor frequency, center frequency, harmonic index, spectral analysis, accelerometer, movement disorders, Movement Disorder Society criteria
- MeSH terms
- Adolescent, Adult, Aged, Analysis of Variance, Biomechanical Phenomena, Female, Hand, Humans, Functional Laterality, Male, Middle Aged, Neurologic Examination, Severity of Illness Index, Case-Control Studies, Essential Tremor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Essential tremor – assessment of tremor accelerometric parameters' symmetry and the relationship between hand dominance and severity of tremor. https://app.cochat.ai/papers/10.1016/s0028-3843(14)60022-0
- The paper
- Machowska-Majchrzak, A., Pierzchała, K., Pietraszek, S., & Łabuz-Roszak, B. (2011). Essential tremor – assessment of tremor accelerometric parameters' symmetry and the relationship between hand dominance and severity of tremor. Neurologia i Neurochirurgia Polska. https://doi.org/10.1016/s0028-3843(14)60022-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.