CoChat

Effects of unfractionated and low molecular weight heparin on antiphospholipid antibody binding in vitro

Franklin, R · 2003 · Obstetrics & Gynecology
Cited by 72

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare the efficacy of unfractionated heparin and low molecular weight heparin in the in vitro binding of antiphospholipid antibodies obtained from the sera of patients with recurrent pregnancy loss. METHODS: Women with immunoglobulin (Ig) G antibodies to the phospholipids cardiolipin and phosphatidylserine were selected based on a positive test by a standard enzyme-linked immunosorbent assay (ELISA). The sera were reassayed for antiphospholipid antibodies in a modified ELISA using increasing doses of unfractionated heparin or low molecular weight heparin (0, 16, 32, 64, 128, and 256 IU). Sera were fractionated by unfractionated and low molecular weight heparin affinity chromatography to compare the binding avidity and antiphospholipid antibody activity. RESULTS: All sera demonstrated a dose-dependent inhibition in measured antiphospholipid antibody activity with the addition of unfractionated or low molecular weight heparin. Levels of IgG cardiolipin and IgG phosphatidylserine were significantly inhibited in the presence of 32 IU of low molecular weight heparin (P <.001 and P <.05, respectively) and in the presence of 64 IU of unfractionated heparin (P <.001 and P <.05, respectively). Antiphospholipid antibody binding activity in serum as measured in the ELISA was maximally reduced 76-89% with 256 IU of either heparin derivative. Affinity chromatography with unfractionated or low molecular weight heparin columns absorbed 72% and 66% of IgG cardiolipin activity, respectively, and 46% and 54% of IgG phosphatidylserine activity, respectively. CONCLUSION: These data suggest that low molecular weight heparin and unfractionated heparin reduce the in vitro binding of antiphospholipid antibodies on a per unit basis. Both heparins demonstrate binding activity similar to that of antiphospholipid antibodies in vitro.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0029-7844(02)02520-6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Franklin, R.
Venue
Obstetrics & Gynecology
Published
2003-03
Volume
101
Issue
3
Pages
455-462
ISSN
0029-7844 (ISSN-L)
OpenAlex
W1983823516
Cited by
72
References
1
FWCI
3.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of unfractionated and low molecular weight heparin on antiphospholipid antibody binding in vitro. https://app.cochat.ai/papers/10.1016/s0029-7844(02)02520-6
The paper
Franklin, R. (2003). Effects of unfractionated and low molecular weight heparin on antiphospholipid antibody binding in vitro. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(02)02520-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.