Determinants of ventilatory instability and variability
The DOI matches its Crossref record; 80 of the 87 references it cites were found in a registry or an index.
Abstract
This paper reviews the major mechanisms that can give rise to various forms of variability in the ventilatory pattern. First, an elevated controller gain, coupled with the presence of delays and response lags in the chemoreflex loops, can lead to instability in feedback control and give rise to periodic breathing. This form of ventilatory stability can be assessed quantitatively by employing the concept of 'loop gain'. Several different methods of estimating loop gain from steady state or dynamic respiratory measurements are discussed. An inherently stable respiratory control system can also exhibit periodic behavior due to the influence of primary fluctuations in sleep-wake state and other physiological variables, such as cardiac output and cerebral blood flow. Self-sustained, irregular ventilatory fluctuations may be generated by nonlinear dynamic interactions between various components of the respiratory control system, such as the lung vagal afferents and the respiratory pattern generator, or through the propagation of stochastic disturbances around the chemoreflex loops.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Control of breathing is a negative feedback system in which chemoreceptors (e.g., in the carotid body; “controller”) and the lung (“plant”) try to maintain a PaCO2 at roughly 40 mmHg.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [344]
Citations
Cites
Guilleminault, C., Tilkian, A., & Dement, W. C. (1976) · Annual Review of Medicine · doi:10.1146/annurev.me.27.020176.002341 · Cited by 1,810
Factors inducing periodic breathing in humans: a general model
Khoo, M. C., Kronauer, R. E., Strohl, K. P., & Slutsky, A. S. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.3.644 · Cited by 579
Self-citationJernérus, R., Lundin, G., & Pugh, L. G. C. F. (1963) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1963.tb02717.x · Cited by 447
Dempsey, J. A., & Pack, A. I. (1994) · M. Dekker eBooks · Cited by 424
Control of Breathing During Sleep
Phillipson, E. A., & Bowes, G. (1986) · Comprehensive Physiology · doi:10.1002/j.2040-4603.1986.tb01069.x · Cited by 335
Respiration and wakefulness in man.
Bülow, K. (1963) · PubMed · Cited by 333
PATHOLOGICAL CONDITIONS RESULTING FROM INSTABILITIES IN PHYSIOLOGICAL CONTROL SYSTEMS*
Glass, L., & Mackey, M. C. (1979) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1979.tb29471.x · Cited by 324
Influence of cerebral activity in wakefulness on regulation of breathing
Fink, B. R. (1961) · Journal of Applied Physiology · doi:10.1152/jappl.1961.16.1.15 · Cited by 316
Regulation of Respiration: (First of Three Parts)
Berger, A. J., Mitchell, R. A., & Severinghaus, J. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197707142970206 · Cited by 295
Mechanisms of hypoxia‐induced periodic breathing during sleep in humans.
Berssenbrugge, A., Dempsey, J., Iber, C., Skatrud, J., & Wilson, P. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014906 · Cited by 286
Research works printed but not linked: 3
- Bruce, 1993, Upper airway and postural influences on complexity of breathing pattern of anesthetized rats, FASEB J., 7, A459
- Klein, 1930, Untersuchungen uber das Cheyne–Stokesche Atsmungsphanomen, Verh. Deutsch Ges. Inn. Med., 42, 217
- Younes, 1989, The physiologic basis of central apnea and periodic breathing, Curr. Pulmonol., 10, 265
Cited by
Items 101–200 of 299
Badr, M. S. (2005) · Primary Care Clinics in Office Practice · doi:10.1016/j.pop.2005.02.003 · Cited by 31
Hypocapnia Is Not a Predictor of Central Sleep Apnea in Patients with Cirrhosis
Javaheri, S., Almoosa, K. F., Saleh, K. M. M., & Mendenhall, C. L. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-910oc · Cited by 27
Dempsey, J., & Welch, J. F. (2023) · Seminars in Respiratory and Critical Care Medicine · doi:10.1055/s-0043-1770342 · Cited by 12
Potential therapeutic targets in obstructive sleep apnoea
Saboisky, J. P., Chamberlin, N. L., & Malhotra, A. (2009) · Expert Opinion on Therapeutic Targets · doi:10.1517/14728220903005608 · Cited by 27
“Respiratory instability is quantified by ‘loop gain’, the ventilatory response to disturbance ratio [70,72,73].”
Control theory in biology and medicine: Introduction to the special issue
Thomas, P. J., Olufsen, M. S., Sepulchre, R. J., Iglesias, P. A., Ijspeert, A. J., & Srinivasan, M. (2019) · Biological Cybernetics · doi:10.1007/s00422-018-00791-5 · Cited by 29
Wang, D., Grunstein, R. R., & Teichtahl, H. (2006) · Sleep And Breathing · doi:10.1007/s11325-006-0090-x · Cited by 28
“Recent work has highlighted the concept of loop gain as a measure of the stability or instability of a system with a high loop gain indicating instability and thus increased likelihood of SDB [1, 2 , 5]. Within loop gain, the controller gain (i.e.”
BackgroundRespiratory Long-Term Facilitation: Too Much or Too Little of a Good Thing?
Mahamed, S., & Mitchell, G. S. (2007) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-73693-8_39 · Cited by 26
Variability analysis of the respiratory volume based on non-linear prediction methods
Caminal, P., Dominge, L., Giraldo, B. F., Vallverdu, M., Benito, S., Vázquez-Mata, G., & Kaplan, D. T. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351015 · Cited by 25
“The hypotheses on the physiological mechanisms governing respiratory volume variability are based on the non-linear dynamic interactions between various components of the respiratory control system, such as the lung vagal afferents and the respiratory pattern generator, or through the propagation of stochastic disturb…”
BackgroundMethodPeriodic breathing in healthy humans at exercise in hypoxia*
Hermand, É., Pichon, A., Lhuissier, F., & Richalet, J. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00832.2014 · Cited by 26
“The factors affecting breathing instability have been extensively discussed (11, 22).”
BackgroundLitvin, D. G., Denstaedt, S. J., Borkowski, L. F., Nichols, N. L., Dick, T. E., Smith, C. B., & Jacono, F. J. (2020) · Brain Behavior and Immunity · doi:10.1016/j.bbi.2020.02.006 · Cited by 28
“Consequently, ventilatory behaviors such as re-setting sighs that typically act to restore normal ventilatory patterning may be less effective during SLI (Khoo, 2000; Nakamura et al., 2003; Baldwin et al., 2004; Yamauchi et al., 2008; Nguyen et al., 2012; Vlemincx et al., 2012, 2013; Ramirez, 2014).”
BackgroundPatrician, A., Anholm, J. D., & Ainslie, P. N. (2024) · The Journal of Physiology · doi:10.1113/jp285427 · Cited by 26
Schmickl, C. N., Orr, J. E., Sands, S. A., Alex, R. M., Azarbarzin, A., McGinnis, L., White, S. L., Mazzotti, D. R., Nokes, B. T., Owens, R. L., et al. (2024) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202305-437oc · Cited by 34
Increased ventilatory variability and complexity in patients with hyperventilation disorder
Bokov, P., Fiamma, M., Chevalier-Bidaud, B., Chenivesse, C., Straus, C., Similowski, T., & Delclaux, C. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00859.2015 · Cited by 28
“Compared with 14 healthy subjects with similar anthropometrics, 23 patients with hyperventilation were characterized by increased variability of resting tidal ventilation (CV of VT median [interquartile]: 26% [19-35] vs.”
BackgroundState and chemical drive modulate respiratory variability
BuSha, B. F., & Stella, M. H. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00951.2001 · Cited by 24
Periodic breathing and genetics
Strohl, K. P. (2003) · Respiratory Physiology & Neurobiology · doi:10.1016/s1569-9048(03)00036-3 · Cited by 26
Central sleep apnea and cardiovascular disease state-of-the-art
Javaheri, S., Giannoni, A., Somers, V. K., Malhotra, A., Emdin, M., & Costanzo, M. R. (2024) · SLEEP · doi:10.1093/sleep/zsae307 · Cited by 23
Resonance as the Mechanism of Daytime Periodic Breathing in Patients with Heart Failure
Sands, S. A., Mebrate, Y., Edwards, B. A., Nemati, S., Manisty, C., Desai, A. S., Wellman, A., Willson, K., Francis, D. P., Butler, J. P., et al. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0761oc · Cited by 23
“Modeling studies have also suggested that a stronger chemoreflex response or higher loop gain yields quasioscillations in the presence of biological noise (24), although a quantitative relationship between oscillatory behavior and reduced stability had not been proposed or tested experimentally until now.”
BackgroundSodium/Proton Exchanger 3 in the Medulla Oblongata and Set Point of Breathing Control
Wiemann, M., Frede, S., Bingmann, D., Kiwull, P., & Kiwull-Schöne, H. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200411-1567oc · Cited by 24
Orini, M., Giraldo, B. F., Bailón, R., Vallverdú, M., Mainardi, L. T., Benito, S., Diaz, I., & Caminal, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649782 · Cited by 24
7-Nitroindazole and posthypoxic ventilatory behavior in the A/J and C57BL/6J mouse strains
Price, E. R., Han, F., Dick, T. E., & Strohl, K. P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2003 · Cited by 23
Periodic Breathing, Arterial Oxyhemoglobin Saturation, and Heart Rate during Sleep at High Altitude
Insalaco, G., Romano, S., Salvaggio, A., Pomidori, L., Mandolesi, G., & Cogo, A. (2012) · High Altitude Medicine & Biology · doi:10.1089/ham.2012.1035 · Cited by 22
“System stability is decreased by hypoxia, increased lung washout times, prolonged lung-chemoreceptor delays, and high controller sensitivity (Khoo et al., 2000).”
Forster, H. V. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00351.2006 · Cited by 23
Manipulation of central blood volume and implications for respiratory control function
Miyamoto, T., Bailey, D. M., Nakahara, H., Ueda, S.-Y., Inagaki, M., & Ogoh, S. (2014) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00987.2013 · Cited by 22
Role of Sensory Stimulation in Amelioration of Obstructive Sleep Apnea
Daulatzai, M. A. (2011) · Sleep Disorders · doi:10.1155/2011/596879 · Cited by 24
“During sleep, cortical neural control— that includes changes in neural drive, and peripheral reflex control of the chest wall muscles, UA dilator muscles, and ventilation, is compromised [67, 68].”
BackgroundThe mechanisms underlying the production of discontinuous gas exchange cycles in insects
Matthews, P. G. D. (2017) · Journal of Comparative Physiology B · doi:10.1007/s00360-017-1121-6 · Cited by 22
Wiemann, M., Frede, S., Tschentscher, F., Kiwull-Schöne, H., Kiwull, P., Bingmann, D., Brinkmann, B., & Bajanowski, T. (2007) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-73693-8_89 · Cited by 20
“As has been shown by others, this set point together with the gain of the (central) respiratory controller is of ample importance for the stability of respiration during sleep (Khoo 2000; Dempsey et al. 2004).”
BackgroundEdwards, B. A., Nava-Guerra, L., Kemp, J. S., Carroll, J. L., Khoo, M. C. K., Sands, S. A., Terrill, P. I., Landry, S. A., & Amin, R. S. (2018) · SLEEP · doi:10.1093/sleep/zsy161 · Cited by 20
Self-citationLong-term facilitation of breathing is absent after episodes of hypercapnic hypoxia in awake humans
Diep, T. T., Khan, T. R., Zhang, R., & Duffin, J. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.08.011 · Cited by 24
Miyamoto, T., Inagaki, M., Takaki, H., Kawada, T., Yanagiya, Y., Sugimachi, M., & Sunagawa, K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1219-x · Cited by 20
“The magnitude of this controlling power can be expressed as the ‘‘total loop gain’’ (Berger et al. 1977; Honda et al. 1983; Khoo 2000).”
BackgroundOptimized Symbolic Dynamics Approach for the Analysis of the Respiratory Pattern
Caminal, P., Vallverdú, M., Giraldo, B. F., Benito, S., Vázquez-Mata, G., & Voss, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856293 · Cited by 20
“are related to an elevated controller gain, coupled with the presence of delays and response lags in the chemoreflex loops that may lead to instability in feedback control and give rise to periodic breathing [12].”
BackgroundThe Role of Animal Models in Developing Pharmacotherapy for Obstructive Sleep Apnea
Kim, L. J., Freire, C., Curado, T. F., Jun, J. C., & Polotsky, V. Y. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8122049 · Cited by 21
Central Sleep Apnea in Kidney Disease
Dharia, S. M., Unruh, M. L., & Brown, L. K. (2015) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2015.06.005 · Cited by 22
Impact of Sodium/Proton Exchanger 3 Gene Variants on Sudden Infant Death Syndrome
Poetsch, M., Nottebaum, B. J., Wingenfeld, L., Frede, S., Vennemann, M. M., & Bajanowski, T. (2009) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.07.018 · Cited by 19
Nava-Guerra, L., Tran, W. H., Chalacheva, P., Loloyan, S., Joshi, B., Keens, T. G., Nayak, K. S., Ward, S. L. D., & Khoo, M. C. K. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01081.2015 · Cited by 18
Self-citationStephenson, R. (2003) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2003.10.011 · Cited by 18
“Wake–sleep transitions represent acute respiratory disturbances because they are associated with rapid changes in some or all of the above parameters, collectively referred to hereafter as the “sleep onset effect” (Longobardo et al., 1982; Khoo, 2000 ).”
BackgroundMethodResultInfluentialTymko, M. M., Young, D. A., Vergel, D., Matenchuk, B. A., Maier, L. E., Sivak, A., Davenport, M. H., & Steinback, C. D. (2023) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00021.2023 · Cited by 20
Loop gain in severely obese women with obstructive sleep apnoea
Bokov, P., Essalhi, M., & Delclaux, C. (2015) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2015.11.003 · Cited by 16
Siriwardhana, L. S., Nixon, G. M., Davey, M. J., Mann, D., Landry, S. A., Edwards, B. A., & Horne, R. S. C. (2020) · Sleep Medicine · doi:10.1016/j.sleep.2020.12.005 · Cited by 19
Rodrigues, G. D., Lago, P. D., & Soares, P. P. D. S. (2021) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2021.103672 · Cited by 17
Ferreira, C. B., Silva, T. M., Silva, P. E., Castro, C. L., Czeisler, C. M., Otero, J. J., Takakura, A. C. T., & Moreira, T. S. (2022) · eLife · doi:10.7554/elife.73130 · Cited by 15
Rodrigues, G. D., Gurgel, J. L., Galdino, I. D. S., da Nóbrega, A. C. L., & Soares, P. P. D. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04441-2 · Cited by 17
Doufas, A. G., & Weingarten, T. N. (2021) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000005370 · Cited by 18
Miyamoto, T., Inagaki, M., Takaki, H., Kawada, T., Shishido, T., Kamiya, A., & Sugimachi, M. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1968-2 · Cited by 17
Tellez, H. F., Morrison, S. A., Neyt, X., Maîresse, O., Piacentini, M. F., Macdonald-Nethercott, E., Pangerc, A., Dolenc‐Grošelj, L., Eiken, O., Pattyn, N., et al. (2016) · SLEEP · doi:10.5665/sleep.5626 · Cited by 20
Langer, T. M., Neumueller, S., Crumley, E., Burgraff, N. J., Talwar, S., Hodges, M. R., Pan, L., & Forster, H. V. (2017) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2017.01.007 · Cited by 16
“Or a compensatory increase in an unknown excitatory neuromodulator may have created a “high-gain controller”, which destabilizes breathing (Asyali et al., 2002, Khoo, 2000).”
Increased propensity for apnea via dopamine-induced carotid body inhibition in sleeping dogs
Chenuel, B. J., Smith, C. A., Henderson, K. S., & Dempsey, J. A. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00749.2004 · Cited by 16
“It has been proposed that the propensity for breathing instability and periodicity during sleep is enhanced by the relative dominance of carotid (over central) chemoreceptor contributions to the total ventilatory drive (11).”
BackgroundTailored treatment strategies for obstructive sleep apnea
Shin, W. C., Jen, R., Li, Y., & Malhotra, A. (2015) · Respiratory Investigation · doi:10.1016/j.resinv.2015.09.007 · Cited by 17
“[30] Khoo M.”
Giraldo, B. F., Arizmendi, C., Romero, E. E., Alquézar, R., Caminal, P., Benito, S., & Ballesteros, D. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259607 · Cited by 17
“The study of variability in the respiratory pattern has been discussed in [ 5-8 ].”
BackgroundA multichannel, wireless telemetric microsystem for small animal studies
Liu, C.-C., O'Connor, E., & Strohl, K. P. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2005.860358 · Cited by 16
Rethinking O2, CO2 and breathing during wakefulness and sleep
Dempsey, J. A., & Gibbons, T. D. (2023) · The Journal of Physiology · doi:10.1113/jp284551 · Cited by 16
Song, G., Tin, C., Giacometti, E., & Poon, C. (2011) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2011.00006 · Cited by 15
Quantifying oscillatory ventilation during exercise in patients with heart failure
Olson, T. P., & Johnson, B. D. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.09.008 · Cited by 14
Central sleep apnea in patients with congestive heart failure
Badr, S. M. (2008) · Heart Failure Reviews · doi:10.1007/s10741-008-9100-3 · Cited by 16
Arizmendi, C., Romero, E. E., Alquézar, R., Caminal, P., Diaz, I., Benito, S., & Giraldo, B. F. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332742 · Cited by 14
“The variability of the breathing pattern was previously analyzed in [4-7].”
BackgroundGender and breathing route modulate cardio-respiratory variability in humans
BuSha, B. F., Hage, E., & Hofmann, C. L. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.02.008 · Cited by 14
“The large number of different operating states of the respiratory control system results from the integration of the drive to breathe generated by the central pattern generator and feedback from respiratory sensors (Khoo, 2000).”
BackgroundExpression of TASK-1 in brainstem and the occurrence of central sleep apnea in rats
Wang, J., Zhang, C., Li, N., Su, L., & Wang, G. (2007) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2007.11.008 · Cited by 15
“Thus, the higher loop gain will result in more instability of the ventilation system (Khoo et al., 1982; Khoo, 2000).”
Indic, P., Bloch‐Salisbury, E., Bednarek, F., Brown, E. N., Paydarfar, D., & Barbieri, R. (2011) · Early Human Development · doi:10.1016/j.earlhumdev.2011.04.001 · Cited by 14
Skow, R. J., Tymko, M. M., MacKay, C. M., Steinback, C. D., & Day, T. A. (2014) · Progress in brain research · doi:10.1016/b978-0-444-63488-7.00009-4 · Cited by 15
Study of the respiratory pattern variability in patients during weaning trials
Giraldo, B. F., Chaparro, J. P. C., Ballesteros, D., Lopez-Rodriguez, L., Geat, D., Benito, S., & Caminal, P. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404093 · Cited by 13
Management of Sleep Apnea Syndromes in Heart Failure
Selim, B. J., & Ramar, K. (2016) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2016.10.004 · Cited by 15
Andrade, D. C., Haine, L., Toledo, C., Díaz, H. S., Quintanilla, R. A., Marcus, N. J., Iturriaga, R., Richalet, J., Voituron, N., & Río, R. D. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01440 · Cited by 14
Sources of breathing pattern variability in the respiratory feedback control loop
Jaworski, J. A., & Bates, J. H. T. (2019) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2019.03.001 · Cited by 13
Do circadian rhythms in respiratory control contribute to sleep-related breathing disorders?
Stephenson, R. (2003) · Sleep Medicine Reviews · doi:10.1016/s1087-0792(03)90002-5 · Cited by 14
Hayashida, Y., Kondo, H., & González, C. (2006) · Advances in experimental medicine and biology · doi:10.1007/0-387-31311-7 · Cited by 13
Hypoventilation and Hyperventilation Syndromes
Duffin, J., & Phillipson, E. A. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-4710-0.00078-x · Cited by 11
Kim, L. J., Shin, M., Pho, H., Tang, W., Hosamane, N. S., Anokye‐Danso, F., Ahima, R. S., Sham, J. S. K., Pham, L. V., & Polotsky, V. Y. (2022) · The Journal of Physiology · doi:10.1113/jp283678 · Cited by 12
“Exuberant ventilatory responses to apnoeas/hypopneas are followed by recurrent episodes of hypoventilation (Khoo, 2000; Khoo et al., 1982), increasing SDB severity (Eckert et al.”
BackgroundNakayama, H., Hokari, S., Ohshima, Y., Matsuto, T., & Shimohata, T. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7368 · Cited by 12
“9 However, this method of measuring breathing instability is time consuming and effort dependent.”
Managements for Obstructive Sleep Apnea in Adults: Review
Tserenpil, G., Gebre, M., Zergham, A. S., Sekhon, A. K., & Malik, B. H. (2020) · Cureus · doi:10.7759/cureus.9905 · Cited by 16
Variability of End-Expiratory Lung Volume in Premature Infants
Émériaud, G., Baconnier, P., Eberhard, A., Debillon, T., Calabrèse, P., & Benchetrit, G. (2010) · Neonatology · doi:10.1159/000281262 · Cited by 12
The effect of sex and body weight on lung volumes during sleep
Avraam, J., Dawson, A., Rochford, P. D., Brazzale, D. J., O’Donoghue, F. J., Trinder, J. C., & Jordan, A. S. (2019) · SLEEP · doi:10.1093/sleep/zsz141 · Cited by 12
Li, L., Tang, X., Kim, S., Zhang, Y., Li, Y., & Fu, P. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203710 · Cited by 12
A New Straw in the Genesis of Cheyne-Stokes Respiration
Lorenzi‐Filho, G., & Genta, P. R. (2008) · CHEST Journal · doi:10.1378/chest.08-0119 · Cited by 11
Obstructive Sleep Apnea Endophenotypes
Raphelson, J. R., Fuentes, A. L., Holloway, B. M., & Malhotra, A. (2024) · Sleep Science · doi:10.1055/s-0044-1788287 · Cited by 15
Badr, M. S., Khayat, R., Allam, J. S., Hyer, S., Mustafa, R. A., Naughton, M. T., Patil, S. P., Pien, G. W., Randerath, W. J., & Won, C. H. J. (2025) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.11860 · Cited by 12
“18 Changes in either parameter alter the magnitude of hypocapnia required to induce central apnea.”
Prediction of the Chemoreflex Gain by Common Clinical Variables in Heart Failure
Mirizzi, G., Giannoni, A., Ripoli, A., Iudice, G., Bramanti, F., Emdin, M., & Passino, C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153510 · Cited by 10
Exercise modulation of cardiorespiratory variability in humans
BuSha, B. F. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.05.002 · Cited by 11
Nocturnal breathing in cyanotic congenital heart disease
Legault, S., Lanfranchi, P. A., Montplaisir, J. Y., Nielsen, T., Dore, A., Khairy, P., Marcotte, F., & Mercier, L. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.014 · Cited by 10
“The most widely accepted theory explains periodic breathing as a selfsustaining oscillation due to the loss of stability in the closed-loop chemical control of ventilation [13].”
BackgroundA Theoretical Analysis of Diving Performance in the Weddell Seal (Leptonychotes weddelli)
Stephenson, R. (2005) · Physiological and Biochemical Zoology · doi:10.1086/432142 · Cited by 10
“In contrast, the physiological mechanisms that mediate the interactions between sleep and breathing are well understood, at least in the context of human pathology (Khoo 2000), whereas the adaptive function of sleep is unknown.”
BackgroundNormal Physiology of the Upper and Lower Airways
Heinzer, R. C., & Sériès, F. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-6645-3.00023-2 · Cited by 11
Effect of spontaneous movement on respiration in preterm infants
Zuzarte, I., Paydarfar, D., & Sternad, D. (2021) · Experimental Physiology · doi:10.1113/ep089143 · Cited by 9
“Experimental and computational studies support the idea that non-linear input–output properties at many levels of organization could destabilize breathing in preterm infants (Khoo, 2000).”
BackgroundInfluentialModeling Patient-Specific Desaturation Patterns in Sleep Apnea
Guerrero, G., Rolle, V. L., Loiodice, C., Amblard, A., Pépin, J., & Hernandez, A. I. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3121170 · Cited by 17
Treatment-emergent central sleep apnea resolves with lower inspiratory pressure
Noah, W. H., Messineo, L., Hete, B., Thompson, E., White, D. P., Farney, R. J., & Sundar, K. M. (2024) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.11492 · Cited by 12
Ginter, G., & Badr, M. S. (2022) · Handbook of clinical neurology · doi:10.1016/b978-0-323-91532-8.00011-2 · Cited by 10
A stochastic and integrative model of breathing
BuSha, B. F., & Banis, G. (2017) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2016.12.012 · Cited by 9
Sleep and Breathing at High Altitude
Mohsenin, V., Javaheri, S., & Dempsey, J. A. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-24288-2.00122-7 · Cited by 9
Ventilatory oscillations at exercise in hypoxia: A mathematical model
Hermand, É., Lhuissier, F., Voituron, N., & Richalet, J. (2016) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2016.10.002 · Cited by 10
Information Flow to Assess Cardiorespiratory Interactions in Patients on Weaning Trials
Vallverdu, M., Tibaduisa, O., Claria, F., Hoyer, D., Giraldo, B. F., Benito, S., & Caminal, P. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260390 · Cited by 9
“he possible causes of breath-to-breath variability in the pattern of breathing have been discussed [ 1 ,2].”
MethodThe Association between Low CO2 Production and Central Sleep Apnea in Men with Heart Failure
Javaheri, S., & Simbartl, L. A. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202207-621oc · Cited by 8
Sleep Disorders and End-Stage Renal Disease
Hanly, P. J. (2007) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2006.11.008 · Cited by 9
Is Intermittent Hypoxia A Cause of Aging?
Giulio, C. D. (2013) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2012.761961 · Cited by 10
“A lack of oxygen can directly damage brain cells; for example, periodic breathing, typical of altitude and aging, is a homeostatic mechanism that tends to reduce respiratory work, even though increased ROS production results (8).”
BackgroundeAMI: A Qualitative Quantification of Periodic Breathing Based on Amplitude of Oscillations
Tellez, H. F., Pattyn, N., Maîresse, O., Dolenc‐Grošelj, L., Eiken, O., Mekjavić, I. B., Migeotte, P., Macdonald-Nethercott, E., MEEUSEN, R. R., & Neyt, X. (2015) · SLEEP · doi:10.5665/sleep.4494 · Cited by 7
Instability of spontaneous breathing patterns in patients with persistent vegetative state
Bien, M.-Y., Yien, H.-W., Hseu, S., Wang, J.-H., & Kou, Y. R. (2004) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2004.09.007 · Cited by 8
Lalley, P. M., & Mifflin, S. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00120.2016 · Cited by 7
“alveolar ventilation-PaCO2 relationship, proportional to the dose given to anesthetized humans (35) and cats (25), indicating that they alter the dynamics of the negative feedback loop (24) between central nervous PCO2/pH chemoreceptors and lungbody tissue gas exchange.”
Lavoie, M., Patel, J. A., & Camacho, M. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2019.06.005 · Cited by 10
Variability in hypoxic response: Could genetics play a role?
Simonson, T. S., & Malhotra, A. (2020) · The Journal of Physiology · doi:10.1113/jp279590 · Cited by 9
“A system with a high loop gain is one prone to instability, whereas a system with low loop gain is intrinsically stable (Khoo, 2000). The loop gain of the ventilatory control system is a function of factors including the controller (i.e. chemoresponsiveness), as well as a plant (based on the efficiency of CO2 excretio…”
BackgroundInfluentialModel-Based Analysis of Mechanisms Responsible for Sleep-Induced Carbon Dioxide Differences
Aittokallio, T. A., Gyllenberg, M., Polo, O. J., Toivonen, J., & Virkki, A. (2006) · Bulletin of Mathematical Biology · doi:10.1007/s11538-005-9059-3 · Cited by 10
“In the experimental studies, much emphasis has been placed on monitoring the relation between systematic periodicities and controller gains to search for the determinants of ventilatory instability and variability (Khoo, 2000).”
BackgroundCOVID-19 and silent hypoxemia in a minimal closed-loop model of the respiratory rhythm generator
Diekman, C. O., Thomas, P. J., & Wilson, C. G. (2024) · Biological Cybernetics · doi:10.1007/s00422-024-00989-w · Cited by 6
“In the literature, one may find reduced models of the central controller for breathing that are less representative of preBötzinger complex neurons than our version of the Butera–Rinzel–Smith model (Khoo et al. 1982; Khoo 2000; Cheng et al. 2010).”
MethodCentral Sleep Apnea, Hypoventilation Syndromes and Periodic Breathing Disorders
Caples, S. M., & Somers, V. K. (2006) · KARGER eBooks · doi:10.1159/000093167 · Cited by 7
Miyamoto, T., Nakahara, H., Ueda, S.-Y., Manabe, K., Kawai, E., Inagaki, M., Kawada, T., & Sugimachi, M. (2015) · Clinical Medicine Insights Cardiology · doi:10.4137/cmc.s18761 · Cited by 6
Maternal thyroid hormone deficiency and cardiorespiratory disorder in rat pups
Rousseau, J.-P., Buteau-Poulin, A., & Kinkead, R. (2019) · Experimental Neurology · doi:10.1016/j.expneurol.2019.112960 · Cited by 9
Metadata
- Authors
- Khoo, M. C. K.
- Affiliations
- University of Southern California (US)
- Corresponding author
- Khoo, Michael C.K
- ORCID
- Khoo, Michael C.K
- Venue
- Respiration Physiology
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 122
- Issue
- 2-3
- Pages
- 167-182
- ISSN
- 0034-5687 (ISSN-L)
- OpenAlex
- W2009978651
- Semantic Scholar
- d45cd69d878f1748b83d2f22839c3c9cbe42468e
- Cited by
- 304
- References
- 87
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 11 · 2023: 11 · 2022: 11 · 2021: 13 · 2020: 15 · 2019: 10 · 2018: 9 · 2017: 10 · 2016: 19 · 2015: 10 · 2014: 9 · 2013: 12 · 2012: 19
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Respiration Physiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01hl058725-02)
- National Heart, Lung, and Blood Institute (HL-58725)
- National Center for Research Resources (P41RR001861, RR01861)
- Topics
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Keywords
- ventilatory instability, periodic breathing, loop gain, control gain, respiratory control system, sleep-wake states, vagal afferents, nonlinear dynamics, random perturbations, cardiac output, cerebral blood flow
- MeSH terms
- Algorithms, Animals, Computer Simulation, Feedback, Humans, Models, Biological, Respiratory Mechanics, Nonlinear Dynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.