Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record.

Preschool vision screening: Rationale, methodology and outcome

Open access
Simons, Kurt·1996·Survey of Ophthalmology

Abstract

Although population outcome studies support the utility of preschool screening for reducing the prevalence of amblyopia, fundamental questions remain about how best to do such screening. Infant photoscreening to detect refractive risk factors prior to onset of esotropia and amblyopia seems promising, but our current understanding of the natural history of these conditions is limited, thus limiting the prophylactic potential of early screening. Screening for strabismic, refractive and ocular disease conditions directly associated with amblyopia is more clearly proven, but the diversity of equipment, methods and subject populations studied make it difficult to draw precise summary conclusions at this point about the efficacy of photoscreening. Sensory-based testing of preschool-age children exhibits a similar combination of promise and limitations. The visual acuity tests most widely used for this purpose are prone to problems of testability and false negatives. Moreover, the utility of random-dot stereograms has been confused by misapplication, and new small-target binocularity tests, while attractive, are as yet inadequately field-proven. The evaluation standard for any screening modality is treatment outcome. However, variables in amblyopia classification and quantitative definition differences, timing of presentation, nonequivalent treatment comparisons, and compliance variability have been uncontrolled in virtually all extant studies of amblyopia treatment outcome, making it difficult or impossible to evaluate either the relative efficacy of different treatment regimens for amblyopia or the effects of age on treatment outcome within the preschool age range. The latter issue is a central one, since existence of such an age effect is the primary rationale for screening at younger rather than older preschool ages. The relatively low prevalence of amblyopia makes it difficult to achieve a high screening yield in terms of predictive value, but functionally increasing prevalence by selective screening of high risk populations causes further problems. Unless a "supertest" can be devised, with very high sensitivity and specificity, health policy decisions will be required to determine which of these two characteristics should be emphasized in screening programs. Performance of screening tests can be optimized, however, with adequate training, perhaps via instructional videotapes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0039-6257(97)81990-x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 267

Metadata

Authors
Simons, K.
Venue
Survey of Ophthalmology
Publisher
Elsevier BV
Published
1996-07
Volume
41
Issue
1
Pages
3-30
ISSN
0039-6257 (ISSN-L)
OpenAlex
W2052499257
Cited by
267
References
0
FWCI
7.33
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preschool vision screening: Rationale, methodology and outcome. https://app.cochat.ai/papers/10.1016/s0039-6257(97)81990-x
The paper
Simons, K. (1996). Preschool vision screening: Rationale, methodology and outcome. Survey of Ophthalmology. https://doi.org/10.1016/s0039-6257(97)81990-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.