Large receptive fields for optic flow detection in humans
Open accessThe DOI matches its Crossref record.
Abstract
We used a psychophysical summation technique to study the properties of detectors tuned to radial, circular and translational motion, and to determine the spatial extent of their receptive fields. Signal-to-noise motion thresholds were measured for patterns curtailed spatially in various ways. Sensitivity for radial, circular and translational motion increased with stimulus area at a rate predicted by an ideal integrator. When sectors of noise were added to the stimulus, sensitivity decreased at a rate consistent with an ideal integrator. Summation was tested for large annular stimuli, and shown to hold up to 70 degrees in some cases, suggesting very large receptive fields for this type of motion (consistent with the physiology of neurones in the dorsal region of the medial superior temporal area (MSTd)). This is a far greater area than observed for summation of contrast sensitivity to gratings (Anderson SJ and Burr DC, Vis Res 1987;29:621-635, and to this type of stimuli (Morrone MC, Burr DC and Vaina LM, Nature 1995;376:507-509, consistent with the suggestion that the two techniques examine different levels of motion analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stevens' Handbook of Experimental Psychology
(2002) · Wiley eBooks · doi:10.1002/0471214426 · Cited by 1,632
A cortical area that responds specifically to optic flow, revealed by fMRI
Morrone, M. C., Tosetti, M., Montanaro, D., Fiorentini, A., Cioni, G., & Burr, D. C. (2000) · Nature Neuroscience · doi:10.1038/81860 · Cited by 392
Self-citationNeri, P., Morrone, M. C., & Burr, D. C. (1998) · Nature · doi:10.1038/27661 · Cited by 339
Self-citationSpatiotopic temporal integration of visual motion across saccadic eye movements
Melcher, D., & Morrone, M. C. (2003) · Nature Neuroscience · doi:10.1038/nn1098 · Cited by 212
Temporal dynamics of chromatic tuning in macaque primary visual cortex
Cottaris, N. P., & De Valois, R. L. (1998) · Nature · doi:10.1038/27666 · Cited by 195
Metadata
- Authors
- Burr, D. C., Concetta Morrone, M., & Vaina, L. M.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1998-06
- Volume
- 38
- Issue
- 12
- Pages
- 1731-1743
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2162688526
- Cited by
- 114
- References
- 0
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large receptive fields for optic flow detection in humans. https://app.cochat.ai/papers/10.1016/s0042-6989(97)00346-5
- The paper
- Burr, D. C., Concetta Morrone, M., & Vaina, L. M. (1998). Large receptive fields for optic flow detection in humans. Vision Research. https://doi.org/10.1016/s0042-6989(97)00346-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.