Chapter 8 Quantitation of Protein
The DOI matches its Crossref record, with a small difference in title or year; 37 of the 38 references it cites were found in a registry or an index.
Abstract
The measurement of protein concentration in an aqueous sample is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantitation assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Methods are described to provide information on how to analyze protein concentration using UV protein spectroscopy measurements, traditional dye-based absorbance measurements; BCA, Lowry, and Bradford assays and the fluorescent dye-based assays; amine derivatization and detergent partition assays. The observation that no single assay dominates the market is due to specific limitations of certain methods that investigators need to consider before selecting the most appropriate assay for their sample. Many of the dye-based assays have unique chemical mechanisms that are prone to interference from chemicals prevalent in many biological buffer preparations. A discussion of which assays are prone to interference and the selection of alternative methods is included.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Systematic errors of up to a factor of 2 may therefore arise from the selection of a non-optimal protein standard (14).”
From A “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards (2014) · cites this paper as [14]
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331 · cited 2×
“Folin and Ciocalteu’s reagent The preparation of this reagent has been described (Lowry et al., 1951); however, the solution can be obtained from commercial sources (Sigma).”
BackgroundMethodBradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302 · cited 2×
“The Bradford assay encompasses various preparations of the dye Coomassie Brilliant Blue G-250 used for protein quantitation purposes, and was first described by Bradford (1976). The basic mechanism of the assay is the binding of the dye at acidic pH to arginine, histidine, phenylalanine, tryptophan and tyrosine residu…”
MethodMeasurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
A simplification of the protein assay method of Lowry et al. which is more generally applicable
Peterson, G. L. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90043-4 · Cited by 8,524 · cited 1×
“variation, as color development is due not only to the reduced copper– amide bond complex but also to tyrosine, tryptophan, and to a lesser extent cystine, cysteine, and histidine residues (Peterson, 1977; Wu et al., 1978).”
BackgroundCalculation of protein extinction coefficients from amino acid sequence data
Gill, S. C., & von Hippel, P. H. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90602-7 · Cited by 5,283
How to measure and predict the molar absorption coefficient of a protein
Pace, C. N., Vajdos, F., Fee, L., Grimsley, G., & Gray, T. (1995) · Protein Science · doi:10.1002/pro.5560041120 · Cited by 3,907 · cited 2×
“, insulin), themodel can display deviations of up to 15% from that determined by physicalmethods (Pace et al., 1995).”
BackgroundMethodStoscheck, C. M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82008-p · Cited by 1,438 · cited 3×
“Concentrations were obtained from product inserts and references (Bradford, 1976; Peterson, 1979; Smith et al., 1985; Stoscheck, 1990), where there is not a consensus of values a range is given.”
BackgroundMethodRead, S. M., & Northcote, D. H. (1981) · Analytical Biochemistry · doi:10.1016/0003-2697(81)90321-3 · Cited by 1,421 · cited 1×
“Changes in the formulation of the Bradford reagent are reported to change the response generated from specific proteins; therefore, care should be taken when comparing Bradford data from different suppliers or preparations (Chan et al., 1995; Friedenauer and Berlet, 1989; Lopez et al., 1993; Read and Northcote, 1981).”
MethodReview of the folin phenol protein quantitation method of lowry, rosebrough, farr and randall
Peterson, G. L. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90222-7 · Cited by 1,147 · cited 3×
“Initially, the Biuret reaction involves the reduction of copper (Cu2þ to Cuþ) by proteins in alkaline solutions, followed by the enhancement stage, the reduction of the Folin–Ciocalteu reagent (phosphomolybdate and phosphotungstate) (Peterson, 1979) producing a characteristic blue color with absorbance maxima at 750 n…”
MethodWiechelman, K. J., Braun, R. D., & Fitzpatrick, J. D. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90383-1 · Cited by 766 · cited 1×
“The chemical reaction is temperature dependent with different functional groups displaying a different reactivity at elevated temperatures, which result in less protein variability (Wiechelman et al., 1988).”
BackgroundMeasurement of protein by spectrophotometry at 205 nm
Scopes, R. K. (1974) · Analytical Biochemistry · doi:10.1016/0003-2697(74)90034-7 · Cited by 760
Colorimetric protein assay techniques
Sapan, C. V., Lundblad, R. L., & Price, N. C. (1999) · Biotechnology and Applied Biochemistry · doi:10.1111/j.1470-8744.1999.tb00538.x · Cited by 505 · cited 1×
“The exact mechanism is however still not fully understood (Sapan et al., 1999).”
BackgroundGroves, W. E., Davis, F. C., & Sells, B. H. (1968) · Analytical Biochemistry · doi:10.1016/0003-2697(68)90307-2 · Cited by 449
A Fluorescence-Based Protein Assay for Use with a Microplate Reader
Lorenzen, A., & Kennedy, S. W. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1504 · Cited by 292
Assays for Determination of Protein Concentration
Olson, B. J. S. C., & Markwell, J. (2007) · Current Protocols in Pharmacology · doi:10.1002/0471141755.pha03as38 · Cited by 244
Effect of Light Scattering on Ultraviolet Difference Spectra1
Leach, S. J., & Scheraga, H. A. (1960) · Journal of the American Chemical Society · doi:10.1021/ja01503a008 · Cited by 243
Assays for Determination of Protein Concentration
Olson, B. J. S. C., & Markwell, J. (2007) · Current Protocols in Protein Science · doi:10.1002/0471140864.ps0304s48 · Cited by 239 · cited 2×
“1, or other reviews (Olson and Markwell, 2007) for assay selection.”
BackgroundOzols, J. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82046-5 · Cited by 188 · cited 1×
“, 2008), Kjeldahl nitrogen method, amino acid analysis (Ozols, 1990), gravimetric determination (Blakeley and Zerner, 1975), immunological, and quantitative gel electrophoresis with fluorescent staining.”
MethodBantan, T., Kassai, M., & Grant, K. B. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5338 · Cited by 143 · cited 1×
“Three dyes that have been used to quantitate proteins, or amino acids in a microplate format include o-phthalaldehyde (OPA) (Hammer and Nagel, 1986), Fluorescamine (Lorenzen and Kennedy, 1993), and 3-(4-carboxybenzoyl)quinoline-2-carboxyaldehyde (CBQCA) (Asermely et al., 1997; Bantan-Polak et al., 2001; You et al., 19…”
MethodEpicocconone, A Novel Fluorescent Compound from the Fungus Epicoccum nigrum
Bell, P. J. L., & Karuso, P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035496+ · Cited by 130 · cited 1×
“A noncovalent amine reactive dye epicocconone can also be used for total protein assays in solution (Sigma), for which the mechanism has been reported (Bell and Karuso, 2003; Coghlan et al., 2005).”
BackgroundJones, L. J., Haugland, R. P., & Singer, V. L. (2003) · BioTechniques · doi:10.2144/03344pt03 · Cited by 130 · cited 2×
“The NanoOrange assay is limited by the need to heat samples to 90 C to denature the proteins thereby reducing the proteinto-protein variability ( Jones et al., 2003).”
BackgroundMethodA Comparison of Protein Quantitation Assays for Biopharmaceutical Applications
Noble, J. E., Knight, A. E., Reason, A. J., Matola, A. D., & Bailey, M. J. A. (2007) · Molecular Biotechnology · doi:10.1007/s12033-007-0038-9 · Cited by 112 · cited 4×
“Figure used with permission from Noble et al. (2007). 80 James E.”
BackgroundMethodInfluentialSelf-citationYou, W. W., Haugland, R. P., Ryan, D., & Haugland, R. P. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9920 · Cited by 102
Fountoulakis, M., Juranville, J.-F., & Manneberg, M. (1992) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(94)90078-7 · Cited by 88
Toward Système International d’Unité-traceable protein quantification: From amino acids to proteins
Burkitt, W. I., Pritchard, C., Arsene, C. G., Henrion, A., Bunk, D. M., & O’Connor, G. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.02.010 · Cited by 85 · cited 1×
“Alternative methods not detailed in this chapter include isotope dilution mass spectrometry (ID IC MS/MS) (Burkitt et al., 2008), Kjeldahl nitrogen method, amino acid analysis (Ozols, 1990), gravimetric determination (Blakeley and Zerner, 1975), immunological, and quantitative gel electrophoresis with fluorescent stai…”
MethodSensitivity and variability of the Bradford protein assay in the presence of detergents
Friedenauer, S., & Berlet, H. H. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90636-2 · Cited by 82 · cited 1×
“Changes in the formulation of the Bradford reagent are reported to change the response generated from specific proteins; therefore, care should be taken when comparing Bradford data from different suppliers or preparations (Chan et al., 1995; Friedenauer and Berlet, 1989; Lopez et al., 1993; Read and Northcote, 1981).”
MethodMechanism of Reversible Fluorescent Staining of Protein with Epicocconone
Coghlan, D. R., Mackintosh, J. A., & Karuso, P. (2005) · Organic Letters · doi:10.1021/ol050665b · Cited by 76 · cited 1×
“A noncovalent amine reactive dye epicocconone can also be used for total protein assays in solution (Sigma), for which the mechanism has been reported (Bell and Karuso, 2003; Coghlan et al., 2005).”
BackgroundDaban, J., Bartolomé, S., & Samsó, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90085-8 · Cited by 72
An improved bradford protein assay for collagen proteins
López, J. M., Imperial, S., Valderrama, R., & Navarro, S. (1993) · Clinica Chimica Acta · doi:10.1016/0009-8981(93)90009-s · Cited by 68 · cited 1×
“Changes in the formulation of the Bradford reagent are reported to change the response generated from specific proteins; therefore, care should be taken when comparing Bradford data from different suppliers or preparations (Chan et al., 1995; Friedenauer and Berlet, 1989; Lopez et al., 1993; Read and Northcote, 1981).”
MethodMechanism Studies of Coomassie Blue and Silver Staining of Proteins
de Moreno, M. R., Smith, J. F., & Smith, R. V. (1986) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600750919 · Cited by 58
[6] Protein concentration measurements: The dry weight
Kupke, D. W., & Dorrier, T. E. (1978) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(78)48008-5 · Cited by 44 · cited 1×
“, 1988) and Kjeldahl and gravimetric analysis (Kupke and Dorrier, 1978).”
MethodWu, A. M., Wu, J. C., & Herp, A. (1978) · Biochemical Journal · doi:10.1042/bj1750047 · Cited by 29 · cited 1×
“variation, as color development is due not only to the reduced copper– amide bond complex but also to tyrosine, tryptophan, and to a lesser extent cystine, cysteine, and histidine residues (Peterson, 1977; Wu et al., 1978).”
BackgroundQuantitative Determination of Protamines by Coomassie Blue G Assay
Chan, J. K., Thompson, J. W., & Gill, T. A. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1211 · Cited by 18 · cited 1×
“Changes in the formulation of the Bradford reagent are reported to change the response generated from specific proteins; therefore, care should be taken when comparing Bradford data from different suppliers or preparations (Chan et al., 1995; Friedenauer and Berlet, 1989; Lopez et al., 1993; Read and Northcote, 1981).”
MethodEvaluation of Amino Acid Analysis as Reference Method to Quantitate Highly Purified Proteins
Sittampalam, G. S., Ellis, R. M., Miner, D. J., Rickard, E. C., & Clodfelter, D. K. (1988) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/71.4.833 · Cited by 17 · cited 2×
“Physical (empirical) methods to determine extinction coefficient include amino acid analysis (AAA) via acid hydrolysis and chromatographic separation of resulting amino acids (Sittampalam et al., 1988) and Kjeldahl and gravimetric analysis (Kupke and Dorrier, 1978).”
MethodAsermely, K. E., Broomfield, C. A., Nowakowski, J. L., Courtney, B. C., & Adler, M. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00172-2 · Cited by 16 · cited 1×
“Three dyes that have been used to quantitate proteins, or amino acids in a microplate format include o-phthalaldehyde (OPA) (Hammer and Nagel, 1986), Fluorescamine (Lorenzen and Kennedy, 1993), and 3-(4-carboxybenzoyl)quinoline-2-carboxyaldehyde (CBQCA) (Asermely et al., 1997; Bantan-Polak et al., 2001; You et al., 19…”
MethodBlakeley, R. L., & Zerner, B. (1975) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(75)35157-4 · Cited by 12 · cited 2×
“, 2008), Kjeldahl nitrogen method, amino acid analysis (Ozols, 1990), gravimetric determination (Blakeley and Zerner, 1975), immunological, and quantitative gel electrophoresis with fluorescent staining.”
MethodHammer, K. D., & Nagel, K. (1986) · Analytical Biochemistry · doi:10.1016/0003-2697(86)90439-2 · Cited by 11 · cited 2×
“f Figures indicate interference concentrations with the NanoOrange and Quant-iT assays ((Hammer and Nagel, 1986) and Quant-iT product insert) in a 40- and 20-ml sample (respectively) using a final reaction volume of 200 ml.”
Method
Cited by
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
A “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards
Wiśniewski, J. R., Hein, M. Y., Cox, J., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.037309 · Cited by 690
Fast and Sensitive Total Protein and Peptide Assays for Proteomic Analysis
Wiśniewski, J. R., & Gaugaz, F. Z. (2015) · Analytical Chemistry · doi:10.1021/ac504689z · Cited by 361
Sáez-Plaza, P., Michałowski, T., Navas, M. J., Asuero, A. G., & Wybraniec, S. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751786 · Cited by 358
Recent developments in the detection of bovine serum albumin
Jahanban-Esfahlan, A., Ostadrahimi, A., Jahanban-Esfahlan, R., Roufegarinejad, L., Tabibiazar, M., & Amarowicz, R. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.07.096 · Cited by 304
Metadata
- Authors
- Noble, J. E., & Bailey, M. J. A.
- Affiliations
- National Physical Laboratory (GB)
- University of Cambridge (GB)
- ORCID
- Noble, James E.
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 2009
- Volume
- 463
- Pages
- 73-95
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W2294062060
- Cited by
- 492
- References
- 38
- Citations by year
- 2026: 22 · 2025: 38 · 2024: 49 · 2023: 21 · 2022: 22 · 2021: 42 · 2020: 34 · 2019: 28 · 2018: 22 · 2017: 24 · 2016: 34 · 2015: 34 · 2014: 36 · 2013: 29 · 2012: 22
- FWCI
- 21.85
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Interaction Studies and Fluorescence Analysis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
- Keywords
- protein quantification, protein concentration measurement, UV spectrophotometry, BCA assay, Lowry assay, Bradford assay, amine derivatization, assay interference, extinction coefficient
- MeSH terms
- Algorithms, Amines, Animals, Biochemistry, Colorimetry, Humans, Indicators and Reagents, Luminescent Measurements, Proteins, Quinolines, Rosaniline Dyes, X-Ray Absorption Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.