Absorption of aerosolized drugs from the rat lung.
The DOI matches its Crossref record.
Abstract
To investigate the absorption of aerosolized drugs from the rat lung, anesthetized animals were allowed to inhale through a tracheal cannula liquid aerosols of drug solutions generated with an air-jet nebulizer. The aerosols had a mass median aerodynamic diameter of 2.81 +/- 0.08 micron and a geometric standard deviation of 2.53 +/- 0.05. At various times after aerosol inhalation, the lungs were removed and assayed for the amount of compound that had not been absorbed. The times (min) necessary for 50% absorption were: antipyrine, 0.25; salicylic acid, 0.67; barbital, 0.93; amitrole, 1.3; urea, 1.4; procainamide, 2.3; guanidine, 3.1; erythromycin, 6.3; benzylpenicillin, 20.5; p-aminohippuric acid, 21.7; mannitol, 26.5; and N-acetylprocainamide ethobromide, 34.5. Comparison with previously reported absorption rates measured after intratracheal injection of 0.1 ml of drug solution showed that drug inhaled as an aerosol was absorbed roughly two times more rapidly than when administered by intratracheal injection. The results suggest that drug absorption may be more rapid from the alveolar region than from the tracheobronchial region of the lung.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Inhaling medicines: delivering drugs to the body through the lungs
Patton, J. S., & Byron, P. R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2153 · Cited by 1,331
The Lungs as a Portal of Entry for Systemic Drug Delivery
Patton, J. S., Fishburn, C. S., & Weers, J. G. (2004) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200409-049ta · Cited by 563
Lung Epithelium–specific Proteins: Characteristics and Potential Applications as Markers
HERMANS, C., & BERNARD, A. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9806064 · Cited by 428
Sakagami, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.012 · Cited by 331
“In Schanker's studies [3,12–27], destructive tissue sampling was undertaken for each data point, which required a substantial number of animal sacrifices following intratracheal instillation.”
BackgroundInfluentialInhaled Therapy in Respiratory Disease: The Complex Interplay of Pulmonary Kinetic Processes
Borghardt, J. M., Kloft, C., & Sharma, A. (2018) · Canadian Respiratory Journal · doi:10.1155/2018/2732017 · Cited by 304
Byron, P. R. (1986) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600750502 · Cited by 253
Vandamme (2008) · International Journal of Nanomedicine · doi:10.2147/ijn.s1045 · Cited by 238
“…molecules, inhalation is also a fast way to get into the body because drug effl ux transporters and metabolizing enzymes are present in the lung at much lower levels than the gastrointestinal tract (Brown et al 1983; Colthorpe et al 1992; Niven et al 1994, Colthorpe et al 1995; Niven et al 1995).”
Lung Clearance of Inhaled Insoluble and Soluble Particles
OBERDÖRSTER, G. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.289 · Cited by 157
“In vivo retention of an inhaled hydrophilic solute is longer in the conducting airways than in the alveolar region (Brown and Schanker, 1983; Oberdorster et al., 1986b), although pore equivalents seem to be of larger size in bronchial than alveolar epithelium (Gatzy and Boucher, 1982).”
Tronde, A., Baran, G., Eirefelt, S., Lennernäs, H., & Bengtsson, U. H. (2002) · Journal of Aerosol Medicine · doi:10.1089/089426802760292627 · Cited by 45
“4–7 The respiratory anatomy, physiology, pathophysiology, the aerosol characteristics, and the inhalation device are parameters that affect the lung deposition profile of the administered drug.”
Metadata
- Authors
- Brown, R. A., & Schanker, L. S.
- Venue
- Drug Metabolism and Disposition
- Publisher
- Elsevier BV
- Published
- 1983-07
- Volume
- 11
- Issue
- 4
- Pages
- 355-360
- ISSN
- 0090-9556 (ISSN-L)
- OpenAlex
- W1585550046
- Cited by
- 108
- References
- 0
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.