Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature
The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
Objectives The roughness of intraoral hard surfaces can influence bacterial plague retention. The present review evaluates the initial surface roughness of several intraoral hard materials, as well as changes in this surface roughness as a consequence of different treatment modalities. Methods Articles found through Medline searches were included in this review if they met the following criteria: 1) stated threshold surface roughness values and reputed change in surface roughness due to different manipulation techniques; or 2) included standardized surface conditions that could be compared to the treated surface. Results Recently, some in vivo studies suggested a threshold surface roughness for bacterial retention (Ra = 0.2 micron) below which no further reduction in bacterial accumulation could be expected. An increase in surface roughness above this threshold roughness, however, resulted in a simultaneous increase in plaque accumulation, thereby increasing the risk for both caries and periodontal inflammation. The initial surface roughness of different dental materials (e.g., teeth, abutments, gold, amalgam, acrylic resin, resin composite, glass ionomer or compomer and ceramics) and the effect of different treatment modalities (e.g., polishing, scaling, brushing, condensing, glazing or finishing) on this initial surface roughness were analyzed and compared to the threshold surface roughness of 0.2 micron. The microbiological effects of these treatment modalities, if reporte…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Experimental gingivitis in man: II. A Longitudinal Clinical and Bacteriological Investigation
Theilade, E., Wright, W. H., Jensen, S. B., & Löe, H. (1966) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1966.tb01842.x · Cited by 1,038
Quirynen, M., & Bollen, C. M. L. (1995) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1995.tb01765.x · Cited by 1,037
Self-citationThe influence of abutment surface roughness on plaque accumulation and peri‐implant mucositis
Bollen, C. M. L., Papaioanno, W., Van Eldere, J., Schepers, E., Quirynen, M., & Van Steenberghe, D. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070302.x · Cited by 661
Self-citationThe effect of surface roughening of polymers on measured contact angles of liquids
Busscher, H. J., van Pelt, A. W. J., de Boer, P., de Jong, H. P., & Arends, J. (1984) · Colloids and Surfaces · doi:10.1016/0166-6622(84)80175-4 · Cited by 516
Quirynen, M., Marechal, M., Busscher, H. J., Weerkamp, A. H., Darius, P. L., & van Steenberghe, D. (1990) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1990.tb01077.x · Cited by 504
Self-citationQuirynen, M., Bollen, C. M. L., Papaioannou, W., Eldere, J. V., & van Steenberghe, D. (1996) · PubMed · Cited by 431
Self-citationQuirynen, M., Van Der Mei, H. C., Bollen, C. M. L., Schotte, A., Marechal, M., Doornbusch, G. I., Naert, I., Busscher, H. J., & Van Steenberghe, D. (1993) · Journal of Dental Research · doi:10.1177/00220345930720090801 · Cited by 431
Self-citationWillems, G., Lambrechts, P., Braem, M., Celis, J. P., & Vanherle, G. (1992) · Dental Materials · doi:10.1016/0109-5641(92)90106-m · Cited by 339
Self-citationGladys, S., Van Meerbeek, B., Braem, M., Lambrechts, P., & Vanherle, G. (1997) · Journal of Dental Research · doi:10.1177/00220345970760041001 · Cited by 307
Self-citationApse, P., Ellen, R. P., Overall, C. M., & Zarb, G. A. (1989) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1989.tb00863.x · Cited by 292
Research works printed but not linked: 7
- Davidson, 1979, Enige aspecten van het afwerken van composieten, Belgisch Tijdschrift Tandheelkunde, 34, 83
- De Wet, 1980, Dental glazes — Surface roughness and plaque accumulation, Quintessence Int, 9, 127
- Fehér, 1995, Die Ausarbeitung van Keramikrestaurationen mit superfeinen Diamant-instrumenten, Schweiz Monatsschr Zahnmed, 105, 474
- Johannsen, 1989, Surface changes on dentál materials. I. The influence of two different dentifrices on surface roughness measured by laser reflexion and profilometric techniques, Swed Dent J, 13, 267
- Lutz, 1995, Prophylaxepasten-Das neue Abrasiv Perlit im Vergleich zu koventionellen Putzkörpern, Schweiz Monatsschrift Zahnmedizin, 105, 30
- Pröbster, 1992, Effect of fluoride prophylactic agents on titanium surfaces, Int J Oral & Maxillofac Implants, 7, 390
- Von Mierau, 1982, Rauhigkeitsuntersuchungen an vestibúläen und lingualen Zahnoberflächen, Deutsches zahnärztliches Zeitschrift, 37, 176
Cited by
Items 501–600 of 1,866
Ilday, N. Ö., Bayındır, Y. Z., & Erdem, V. (2010) · Materials Research Innovations · doi:10.1179/143307510x12820854748917 · Cited by 28
Ourique, S. A. M., Arrais, C. A. G., Cassoni, A., et al. (2011) · Brazilian Oral Research · doi:10.1590/s1806-83242011000500013 · Cited by 28
Effect of sealer coating and storage methods on the surface roughness of soft liners
Kutlu, I., YANIKOĞLU, N., Kul, E., et al. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.10.004 · Cited by 27
“Fungus adheres more often to rough surfaces than to smooth surfaces.(12,22,23) Three to four days after soft liners are applied, surface roughness may increase.”
BackgroundIonescu, A. C., Hahnel, S., Cazzaniga, G., Ottobelli, M., Braga, R. R., Rodrigues, M. C., & Brambilla, E. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5914-7 · Cited by 35
Cortopassi, L. D. S., Shimokawa, C. A. K., Willers, A. E., & Sobral, M. Â. P. (2019) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12548 · Cited by 32
Tosco, V., Monterubbianesi, R., Orilisi, G., et al. (2020) · Minerva Dental and Oral Science · doi:10.23736/s0026-4970.19.04310-3 · Cited by 27
Surface quality and color stability of posterior composites in acidic beverages
Sirisha, K., & Meenakshi, C. (2020) · Journal of Conservative Dentistry · doi:10.4103/jcd.jcd_291_19 · Cited by 27
“This can lead to caries and periodontal inflammation.[5] Thus, an ideal composite resin should maintain smoother surface with color stability.”
BackgroundAl‐Angari, S. S., Meaigel, S., Almayouf, N., et al. (2021) · Journal of Applied Biomaterials & Functional Materials · doi:10.1177/22808000211058866 · Cited by 27
Microbial Response to Micrometer-Scale Multiaxial Wrinkled Surfaces
Pellegrino, L., Kriem, L. S., Robles, E. S. J., & Cabral, J. T. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c08768 · Cited by 27
Basavarajappa, S., Kheraif, A. A. A., ElSharawy, M., et al. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.09.007 · Cited by 27
Jiao, Y., Ma, S., Li, J., Shan, L., Yang, Y., Li, M., & Chen, J. (2015) · PeerJ · doi:10.7717/peerj.868 · Cited by 31
Lins, F. C. D. R., Ferreira, R. C., da Silveira, R. R., et al. (2016) · International Journal of Dentistry · doi:10.1155/2016/8346782 · Cited by 27
“promote aesthetics, longevity, and periodontal health [1, 2].”
BackgroundMethodYurdagüven, H., Aykor, A., Özel, E., et al. (2012) · European Journal of Dentistry · doi:10.1055/s-0039-1698924 · Cited by 27
Köroğlu, A., Şahın, O., Dede, D. Ö., et al. (2016) · Dental Materials Journal · doi:10.4012/dmj.2016-103 · Cited by 26
“Each test specimen was 811 Dent Mater J 2016; 35(5): 810–816”
BackgroundMethodResultInfluentialYadav, B. K., Tripathi, P., Phukela, S. S., et al. (2018) · The Journal of Indian Prosthodontic Society · doi:10.4103/jips.jips_335_17 · Cited by 26
“Bollen et al.[17] 1997 reported that the threshold Ra for plaque retention of intraoral materials is 0.”
BackgroundInfluentialMeyer-Kobbe, V., Doll, K., Stiesch, M., Schwestka‐Polly, R., & Demling, A. P. (2018) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-018-00165-3 · Cited by 30
“2μm, where the formation of biofilm is not substantially influenced by the surface roughness [8, 52, 62].”
Silva, T. S. D. O., de Freitas, A. R., de Albuquerque, R. F., Pedrazzi, V., Ribeiro, R. F., & Nascimento, C. R. R. (2020) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12888 · Cited by 27
Effect of Surface Roughness of Deciduous and Permanent Tooth Enamel on Bacterial Adhesion
Teutle‐Coyotecatl, B., Contreras‐Bulnes, R., Rodríguez‐Vilchis, L. E., Scougall‐Vilchis, R. J., Enríquez, U. V., Almaguer‐Flores, A., & Arenas-Alatorre, J. A. (2022) · Microorganisms · doi:10.3390/microorganisms10091701 · Cited by 30
“For a long time, the literature has stated that the roughness of intraoral hard surfaces has a great influence on the retention of oral microorganisms and that an increase in surface roughness results in a faster colonization of surfaces and a faster maturation of plaque, leading to an increased risk of caries [10].”
BackgroundBauer, J. R. D. O., Costa, J. F., Carvalho, C. N., et al. (2012) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2012.02.004 · Cited by 26
“This can lead to attachment of pathogenic microorganisms alloy surfaces are rough to the increase in the incidence of oral diseases [29,30] and the acceleration of biocorrosion by providing niches retentive [31].”
BackgroundNicu, E. A., Assche, N. V., Coucke, W., Teughels, W., & Quirynen, M. (2012) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.12022 · Cited by 27
Self-citationHahnel, S., Henrich, A., Rosentritt, M., Handel, G., & Bürgers, R. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3894-y · Cited by 26
“2 lm, implying that higher values for surface roughness cause a significant increase in plaque formation [18].”
BackgroundInfluentialBrambilla, E., Ionescu, A., Fadini, L., Mazzoni, A., Imazato, S., Pashley, D., Breschi, L., & Gagliani, M. (2013) · PubMed · doi:10.3290/j.jad.a28734 · Cited by 31
Surface modification of Ti6Al4V by micro-arc oxidation in AgC2H3O2-containing electrolyte
Teker, D., Muhaffel, F., Acar, Ö. K., Topçuoğlu, N., Külekçi, H., Köse, G. T., Baydoğan, M., & Çimenoǧlu, H. (2018) · Surface Innovations · doi:10.1680/jsuin.18.00007 · Cited by 26
Nanoscale effects of beverages on enamel surface of human teeth: An atomic force microscopy study
Li, P., Oh, C., Kim, H., et al. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103930 · Cited by 26
Abdul-Monem, M. M., & Hanno, K. I. H. (2024) · BMC Oral Health · doi:10.1186/s12903-024-03991-7 · Cited by 25
“The wettability, hardness, and surface properties of acrylic resins may have an impact on plaque buildup [28, 29].”
BackgroundInfluentialNerness, A., Ehrlich, Y., Spolnik, K. J., et al. (2015) · Odontology · doi:10.1007/s10266-014-0191-0 · Cited by 25
Hyun, H., & Ferracane, J. L. (2016) · Dental Materials · doi:10.1016/j.dental.2016.06.011 · Cited by 29
“2 μm, a threshold surface roughness for bacteria retention based on in vivo studies, resulted in a simultaneous increase in plaque accumulation [40].”
BackgroundDoes recharging dental restorative materials with fluoride influence biofilm formation?
Ionescu, A. C., Brambilla, E., & Hahnel, S. (2019) · Dental Materials · doi:10.1016/j.dental.2019.07.019 · Cited by 25
Sajjad, A., Bakar, W. Z. W., Mohamad, D., et al. (2019) · AIMS Materials Science · doi:10.3934/matersci.2019.5.730 · Cited by 25
Conventional and Resin-Modified Glass Ionomer Cement Surface Characteristics after Acidic Challenges
Nica, I., Stoleriu, S., Iovan, A., et al. (2022) · Biomedicines · doi:10.3390/biomedicines10071755 · Cited by 25
Cytotoxicity and anti-biofilm properties of novel hybrid-glass-based caries infiltrant
Nedeljković, I., Zandieh‐Doulabi, B., Abdelaziz, M., Feilzer, A. J., Exterkate, R. A. M., Szafert, S., Gulia, N., Krejci, I., & Kleverlaan, C. J. (2022) · Dental Materials · doi:10.1016/j.dental.2022.11.018 · Cited by 25
Mugri, M. H., Jain, S., Sayed, M. E., et al. (2023) · Biomedicines · doi:10.3390/biomedicines11020491 · Cited by 25
“2 μm as documented in the literature [55].”
Backgroundde Oliveira, A. G., Rocha, R. S., Spinola, M. D. S., Batista, G. R., Bresciani, E., & Caneppele, T. M. F. (2023) · European Journal Of Oral Sciences · doi:10.1111/eos.12921 · Cited by 26
Pacifici, E., Bossù, M., Giovannetti, A., et al. (2014) · PubMed · Cited by 25
Dalkız, M., Sipahi, C., & Beydemir, B. (2008) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2008.00410.x · Cited by 27
Hydrophilicity of dentin bonding systems influences in vitro Streptococcus mutans biofilm formation
Brambilla, E., Ionescu, A. C., Mazzoni, A., Cadenaro, M., Gagliani, M. M., Ferraroni, M., Tay, F. R., Pashley, D. H., & Breschi, L. (2014) · Dental Materials · doi:10.1016/j.dental.2014.05.009 · Cited by 30
“[47] Bollen CM, Lambrechts P, Quirynen M.”
BackgroundPrakki, A., Cilli, R., Mondelli, R. F. L., et al. (2007) · Dental Materials · doi:10.1016/j.dental.2007.06.011 · Cited by 25
Colucci, V., SANTOS, C. D. D., do Amaral, F. L. B., Corona, S. A. M., & Catirse, A. B. C. E. B. (2009) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/j.1708-8240.2009.00269.x · Cited by 34
Synthesis of Nanosilica Fillers for Experimental Dental Nanocomposites and Their Characterisations
Rahim, A. T., Ismail, A. R. H., & Akil, H. M. (2011) · Cited by 25
Kumar, Y., Jain, V., Chauhan, S. S., Bharate, V., Koli, D. K., & Kumar, M. (2017) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.11.017 · Cited by 25
Effect of ionizing radiation on properties of restorative materials
Brandeburski, S. B. N., & Bona, Á. D. (2017) · Dental Materials · doi:10.1016/j.dental.2017.10.006 · Cited by 36
Asiry, M. A., Alshahrani, I., Almoammar, S., et al. (2018) · Materials Research Express · doi:10.1088/2053-1591/aaabe5 · Cited by 25
Lee, D., Mai, H., Thant, P. P., et al. (2019) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2019.11.1.41 · Cited by 25
Wear and hardness of different core build‐up materials
Schmage, P., Nergiz, İ., Sito, F., et al. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31375 · Cited by 25
Alhassan, M., Maawadh, A. M., Labban, N. Y., Alnafaiy, S. M., Al-Otaibi, H. N., & Binmahfooz, A. M. (2022) · Applied Sciences · doi:10.3390/app122311972 · Cited by 27
“It is recommended to have the surface roughness below 0.2 µ m and a minimal plaque-retentive restoration [25].”
BackgroundInfluentialAltınışık, H., & Özyurt, E. (2024) · BMC Oral Health · doi:10.1186/s12903-024-05163-z · Cited by 24
Gürbüz, Ö., Çilingir, A., Dikmen, B., et al. (2020) · European Oral Research · doi:10.26650/eor.20200020 · Cited by 24
“2 μm threshold has been reported to increase the colonization and adhesion of bacteria on composite resin surfaces (12).”
Hjerppe, J., Rodas, S., Korvala, J., Pesonen, P., Kaisanlahti, A., Özcan, M., Suojanen, J., & Reunanen, J. (2021) · Materials · doi:10.3390/ma14041027 · Cited by 30
“2 μm do not affect bacterial adhesion [28,29].”
BackgroundAbualsaud, R., AlEraky, D. M., Akhtar, S., Khan, S. Q., & Gad, M. M. (2021) · The Scientific World JOURNAL · doi:10.1155/2021/5556413 · Cited by 29
“It is believed that the nanoparticles will assume one of the following mechanisms of action to fight Candida; they will generate reactive oxygen species, conjugate with the cell membrane, disrupt cell wall/ membrane activity, or release metal ions [41].”
BackgroundFlexural Properties and Polished Surface Characteristics of a Structural Colored Resin Composite
Mizutani, K., Takamizawa, T., Ishii, R., et al. (2021) · Operative Dentistry · doi:10.2341/20-154-l · Cited by 24
Antimicrobial Activity of a 3D-Printed Polymethylmethacrylate Dental Resin Enhanced with Graphene
Salgado, H., Gomes, A. T. P. C., Duarte, A. S., Ferreira, J. M. F., Fernandes, C., Figueiral, M. H., & Mesquita, P. (2022) · Biomedicines · doi:10.3390/biomedicines10102607 · Cited by 29
“Surface roughness plays an important role in this process [9,10].”
BackgroundEffect of different polishing systems and speeds on the surface roughness of resin composites
Tepe, H., Erdılek, A., Şahin, M., et al. (2022) · Journal of Conservative Dentistry · doi:10.4103/jcd.jcd_395_22 · Cited by 24
Kaptan, A., Öznurhan, F., & Candan, M. (2023) · Polymers · doi:10.3390/polym15030650 · Cited by 24
“2 μm [24], and both self-cured Cention and composite showed this result.”
BackgroundMethodInfluence of environmental conditions on properties of ionomeric and resin sealant materials
Kantovitz, K. R., Pascon, F. M., Correr, G. M., Alonso, R. C. B., Rodrigues, L. K. A., Alves, M. C., & Puppin‐Rontani, R. M. (2009) · Journal of Applied Oral Science · doi:10.1590/s1678-77572009000400006 · Cited by 26
Yazici, A. R., Kugel, G., & Müftü, A. (2007) · The Journal of Contemporary Dental Practice · doi:10.5005/jcdp-8-5-9 · Cited by 24
“2 μm.(33) In the present study none of the tested materials subjected to either finishing/polishing procedure showed an Ra value above this limit.”
BackgroundDifferent polishing methods for zirconia: impact on surface, optical, and mechanical properties
Pfefferle, R., Lümkemann, N., Wiedenmann, F., et al. (2019) · Clinical Oral Investigations · doi:10.1007/s00784-019-02953-6 · Cited by 24
Giti, R., Haghdoost, S., & Ansarifard, E. (2020) · Dental Research Journal · doi:10.4103/1735-3327.280893 · Cited by 24
“,[12] when surface roughness was below the threshold (Ra = 0.”
BackgroundInfluentialScarano, A., Lorusso, F., Inchingolo, F., Postiglione, F., & Petrini, M. (2020) · Materials · doi:10.3390/ma13184174 · Cited by 44
“200 μm, the retention of plaque increases [36].”
BackgroundSchwarz, F., Herten, M., Bieling, K., et al. (2008) · PubMed · Cited by 24
Rizzatti‐Barbosa, C. M., & Ribeiro-Dasilva, M. (2009) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2009.00469.x · Cited by 26
Jeong, H.-Y., Lee, H., & Choi, Y. (2018) · Ceramics International · doi:10.1016/j.ceramint.2018.07.146 · Cited by 24
Lee, J., Saleah, S. A., Jeon, B., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3011136 · Cited by 23
The effects of chitosan addition to glass ionomer cement on microhardness and surface roughness
Soygun, K., Soygun, A., & Doğan, M. C. (2021) · Journal of Applied Biomaterials & Functional Materials · doi:10.1177/2280800021989706 · Cited by 23
Labban, N. Y., Amri, M. D. A., Alnafaiy, S. M., et al. (2021) · Polymers · doi:10.3390/polym13213694 · Cited by 23
“In addition, a rough surface is susceptible to plaque accumulation and bacterial growth, leading to tooth decay and periodontal disease [24,30].”
BackgroundEffect of Orthodontic Appliances on the Oral Environment and Microbiome
Mulimani, P. S., & Popowics, T. E. (2022) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2022.924835 · Cited by 36
“However, the landmark review by Bollenl et al. (34) concluded that an increase in both supra-and subgingival surface roughness resulted in a higher rate of bacterial surface colonization and plaque maturation, thus increasing the risk for caries and periodontal inflammation.”
BackgroundInfluentialIzumida, F. E., Ribeiro, R. C., Giampaolo, E. T., Machado, A. L., Pavarina, A. C., & Vergani, C. E. (2011) · Gerodontology · doi:10.1111/j.1741-2358.2010.00393.x · Cited by 25
Tissue healing under provisional restorations with ovate pontics: A pilot human histological study
Orsini, G., Murmura, G., Artese, L., et al. (2006) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2006.08.009 · Cited by 23
Bacterial viability on surface-modified resin-based dental restorative materials
Rüttermann, S., Bergmann, N., Beikler, T., Raab, W. H.-M., & Janda, R. (2012) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2012.05.005 · Cited by 29
Surface Hydrophilicity and Antifungal Properties of TiO2 Films Coated on a Co-Cr Substrate
Huang, L., Jing, S., Zhuo, O., Meng, X., & Wang, X. (2017) · BioMed Research International · doi:10.1155/2017/2054723 · Cited by 24
Andreotti, A. M., de Sousa, C. A., Goiato, M. C., da Silva, E. V. F., Duque, C., Moreno, A., & Santoso, D. M. D. (2018) · European Journal of Dentistry · doi:10.4103/ejd.ejd_50_18 · Cited by 25
“the groups that received refined polishing, and thus, similar roughness and bacterial growth values were observed.[22,32]”
Surface Roughness of Glass Ionomer Cements after Application of Different Polishing Techniques
Miličević, A., Goršeta, K., van Duinen, R., et al. (2018) · Acta Stomatologica Croatica · doi:10.15644/asc52/4/5 · Cited by 23
“Finishing and polishing are mandatory steps in restorative dentistry that enhance both longevity of restorations and esthetics (5-7).”
Is Deterioration of Surface Properties of Resin Composites Affected by Filler Size?
Elbishari, H., Silikas, N., & Satterthwaite, J. D. (2020) · International Journal of Dentistry · doi:10.1155/2020/2875262 · Cited by 23
“)ere is a direct correlation between surface roughness and plaque accumulation; as surface roughness increases, so does the deposition of plaque [12].”
BackgroundColor stability, surface roughness, and surface morphology of universal composites
Meniawi, M., Şirinsükan, N., & Say, E. C. (2025) · Odontology · doi:10.1007/s10266-025-01108-2 · Cited by 22
Valles, C., Ciurana, X. R., Muñoz, F. M. G., Permuy, M., López‐Alonso, H., & Nart, J. (2018) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.12887 · Cited by 22
Comparative evaluation of surface roughness of posterior primary zirconia crowns
Walia, T., Brigi, C., & KhirAllah, A. R. M. M. (2018) · European Archives of Paediatric Dentistry · doi:10.1007/s40368-018-0382-4 · Cited by 22
Daud, A., Adams, A. J., Shawkat, A., et al. (2020) · Journal of Dentistry · doi:10.1016/j.jdent.2020.103376 · Cited by 22
Özyılmaz, Ö. Y., Kara, O., & Akın, C. (2020) · Microscopy Research and Technique · doi:10.1002/jemt.23558 · Cited by 22
Atalay, S., Çakmak, G., Fonseca, M., Schimmel, M., & Yılmaz, B. (2022) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2021.12.007 · Cited by 23
Influence of the Periodontal Status on the Initial‐Biofilm Formation on Titanium Surfaces
Martínez‐Hernández, M., Olivares‐Navarrete, R., & Almaguer‐Flores, A. (2014) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12251 · Cited by 22
Baroudi, K., Hassan, A., Nabih, S., et al. (2015) · Journal of International Society of Preventive and Community Dentistry · doi:10.4103/2231-0762.159965 · Cited by 22
“2 μm.[13] Different polishing procedure systems and different composite resins produce different levels of surface roughness.”
BackgroundEffectiveness of antibacterial copper additives in silicone implants
Gosau, M., Bürgers, R., Vollkommer, T., Holzmann, T., & Prantl, L. (2012) · Journal of Biomaterials Applications · doi:10.1177/0885328212441957 · Cited by 27
“2 nm has been generally accepted as the average roughness threshold belowwhich the amount of bacterial adhesion cannot be reduced any further.(33,34) SFE is the interaction between cohesion and adhesion forces, and this interaction determines whether wetting, i.”
BackgroundAyaz, E. A., Bağış, B., & Turğut, S. (2013) · Medical Principles and Practice · doi:10.1159/000354297 · Cited by 22
Effects of Toothbrush Hardness on in vitro Wear and Roughness of Composite Resins
Kyoizumi, H., Yamada, J., Suzuki, T., et al. (2013) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-1464 · Cited by 22
Yusoff, N. M., Johari, Y., Rahman, I. A., et al. (2019) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2019.04.014 · Cited by 22
Santos, E. O., Oliveira, P. L. E., de Mello, T. P., dos Santos, A. L. S., Elias, C. N., Choi, S., & de Castro, A. C. R. (2022) · Materials · doi:10.3390/ma15020425 · Cited by 28
“2 μm [51] facilitates a greater microbiological colonization [52,53] owing to features such as the greater area available for micro-organisms adhesion, the protection from shear forces and the chemical changes that favor physicochemical interactions [54].”
BackgroundHahnel, S., Ettl, T., Gosau, M., Rosentritt, M., Handel, G., & Bürgers, R. (2010) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2010.03.001 · Cited by 23
Effects of three food-simulating liquids on the roughness and hardness of CAD/CAM polymer composites
Babaier, R. S., Watts, D. C., & Silikas, N. (2022) · Dental Materials · doi:10.1016/j.dental.2022.04.001 · Cited by 21
Kaleli‐Can, G., Özgüzar, H. F., Kahriman, S., Türkal, M., Göçmen, J. S., Yurtçu, E., & Mutlu, M. (2020) · Materials Today Communications · doi:10.1016/j.mtcomm.2020.101565 · Cited by 21
Fibrin Biopolymer Incorporated with Antimicrobial Agents: A Proposal for Coating Denture Bases
Venante, H. S., Chocano, A. P. C., Marcillo-Toala, O. O., da Silva, R. A., da Costa, R. M. B., Pordeus, M. D., Barraviera, B., Ferreira, R. S., Lara, V. S., Neppelenbroek, K. H., et al. (2021) · Materials · doi:10.3390/ma14071618 · Cited by 22
“The internal surface of the denture bases in both PMMA processing methods are not polished, which may affect the roughness threshold, favoring Candida biofilm adhesion [17,18].”
BackgroundInfluence of Low-pH Beverages on the Two-Body Wear of CAD/CAM Monolithic Materials
Scotti, N., Ionescu, A. C., Comba, A., Baldi, A., Brambilla, E., Vichi, A., Goracci, C., Ciardiello, R., Tridello, A., Paolino, D. S., et al. (2021) · Polymers · doi:10.3390/polym13172915 · Cited by 22
“Smooth and polished surfaces support the esthetic appearance of dental restorations, minimize biofilm formation, bacterial adhesion [40,41], fatigue, chipping, or fracture [42], and improve flexural strength [43].”
D’Ercole, S., Angelis, F. D., Biferi, V., et al. (2022) · Materials · doi:10.3390/ma15051891 · Cited by 21
“2 μm is considered to have a low effect on bacterial adhesion in vivo [14].”
BackgroundArutyunov, S. D., Kirakosyan, L. G., Dubova, L., Kharakh, Y. N., Malginov, N., Ахмедов, Г. Д., & Николаевич, Ц. В. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13020042 · Cited by 26
Surface Characteristics of High Translucent Multilayered Dental Zirconia Related to Aging
Toma, F. R., Bîrdeanu, M., Uțu, I.-D., et al. (2022) · Materials · doi:10.3390/ma15103606 · Cited by 21
“3 μm can be perceived by the tongue, negatively affecting patient comfort [57,58].”
BackgroundBiofilm formation affects surface properties of novel bioactive glass-containing composites
Hyun, H., Salehi, S., & Ferracane, J. L. (2015) · Dental Materials · doi:10.1016/j.dental.2015.10.011 · Cited by 26
Nobre, M. D. A., Azul, A. M., Rocha, E., et al. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.03.004 · Cited by 21
Cury, M. S., da Silva, C. B., Nogueira, R. D., Campos, M. G. D., Palma‐Dibb, R. G., & Geraldo-Martins, V. R. (2017) · Lasers in Medical Science · doi:10.1007/s10103-017-2356-x · Cited by 21
“irregular surfaces, the dental biofilm is formed in larger quantities and presents quicker maturation when compared to flat surfaces [26, 27].”
BackgroundPradíes, G., Godoy‐Ruiz, L., Özcan, M., et al. (2017) · Journal of Prosthodontics · doi:10.1111/jopr.12653 · Cited by 21
Pinheiro, J. B., Vomero, M. P., Nascimento, C. R. R., Watanabe, E., Paranhos, H. D. F. O., Coto, N. P., Dias, R. B. E., Oliveira, V. D. C., & Silva‐Lovato, C. H. (2017) · Biofouling · doi:10.1080/08927014.2017.1403591 · Cited by 23
“According to Bollen et al. (1997), surface roughness values < 0.2 μm hinder biofilm formation and therefore studies to evaluate the oral cavity that is responsible for the initial adhesion of yeast on various surfaces (Samaranayake et al. 1988), and can cause mild to severe infections depending on…”
BackgroundInfluentialJia, L., Tao, S., Yang, J., Liang, K., Yu, Z., Gao, Y., Fan, M., Zhang, M., He, L., & Li, J. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.111409 · Cited by 25
Rao, D. C., Kalavathy, N., Mohammad, H. G., Hariprasad, A., & Kumar, C. R. (2015) · The Journal of Indian Prosthodontic Society · doi:10.4103/0972-4052.164910 · Cited by 24
Metadata
- Authors
- Bollenl, C. M. L., Lambrechts, P., & Quirynen, M.
- Affiliations
- UCLouvain (BE)
- Corresponding author
- Bollenl, Curd M.L.
- Venue
- Dental Materials
- Publisher
- Elsevier BV
- Published
- 1997-07
- Volume
- 13
- Issue
- 4
- Pages
- 258-269
- ISSN
- 0109-5641 (ISSN-L)
- OpenAlex
- W2144742986
- Semantic Scholar
- ea71e437137c9719ca605a5a6589eeec175820ba
- Cited by
- 1,911
- References
- 53
- Citations by year
- 2026: 184 · 2025: 143 · 2024: 125 · 2023: 117 · 2022: 141 · 2021: 115 · 2020: 124 · 2019: 114 · 2018: 118 · 2017: 94 · 2016: 93 · 2015: 72 · 2014: 72 · 2013: 50 · 2012: 56
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Dental Materials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Dental and Craniofacial Research (YO1 DE30001, P50DE009322)
- Topics
- Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- Health Sciences › Dentistry › Periodontics › Oral microbiology and periodontitis research
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Keywords
- surface roughness, oral hard tissue, polishing, scaling, brushing, glazing, composite resin, glass ionomer cement, gold restorations, amalgam, ceramics, caries risk, periodontal inflammation
- MeSH terms
- Dental Abutments, Acrylic Resins, Bacterial Adhesion, Ceramics, Composite Resins, Dental Amalgam, Dental Caries, Dental Materials, Dental Plaque, Glass Ionomer Cements, Gold Alloys, Humans, Periodontitis, Risk Factors, Surface Properties, Tooth, Compomers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.