The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study
Open accessAbstract
Summary Background Public objection to autopsy has led to a search for minimally invasive alternatives. Imaging has potential, but its accuracy is unknown. We aimed to identify the accuracy of post-mortem CT and MRI compared with full autopsy in a large series of adult deaths. Methods This study was undertaken at two UK centres in Manchester and Oxford between April, 2006, and November, 2008. We used whole-body CT and MRI followed by full autopsy to investigate a series of adult deaths that were reported to the coroner. CT and MRI scans were reported independently, each by two radiologists who were masked to the autopsy findings. All four radiologists then produced a consensus report based on both techniques, recorded their confidence in cause of death, and identified whether autopsy was needed. Findings We assessed 182 unselected cases. The major discrepancy rate between cause of death identified by radiology and autopsy was 32% (95% CI 26–40) for CT, 43% (36–50) for MRI, and 30% (24–37) for the consensus radiology report; 10% (3–17) lower for CT than for MRI. Radiologists indicated that autopsy was not needed in 62 (34%; 95% CI 28–41) of 182 cases for CT reports, 76 (42%; 35–49) of 182 cases for MRI reports, and 88 (48%; 41–56) of 182 cases for consensus reports. Of these cases, the major discrepancy rate compared with autopsy was 16% (95% CI 9–27), 21% (13–32), and 16% (10–25), respectively, which is significantly lower (p<0·0001) than for cases with no definite cause of death. The most common imaging errors in identification of cause of death were ischaemic heart disease (n=27), pulmonary embolism (11), pneumonia (13), and intra-abdominal lesions (16). Interpretation We found that, compared with traditional autopsy, CT was a more accurate imaging technique than MRI for providing a cause of death. The error rate when radiologists provided a confident cause of death was similar to that for clinical death certificates, and could therefore be acceptable for medicolegal purposes. However, common causes of sudden death are frequently missed on CT and MRI, and, unless these weaknesses are addressed, systematic errors in mortality statistics would result if imaging were to replace conventional autopsy. Funding Policy Research Programme, Department of Health, UK.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probable Inference, the Law of Succession, and Statistical Inference
Wilson, E. B. (1927) · Journal of the American Statistical Association · doi:10.1080/01621459.1927.10502953 · Cited by 4,476
Smithson, M. (2000) · SAGE Publications Ltd eBooks · doi:10.4135/9781446218525 · Cited by 1,871
Improved confidence intervals for the difference between binomial proportions based on paired data
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19981130)17:22<2635::aid-sim954>3.0.co;2-c · Cited by 416
Roulson, J., Benbow, E. W., & Hasleton, P. S. (2005) · Histopathology · doi:10.1111/j.1365-2559.2005.02243.x · Cited by 374
Self-citationPatriquin, L., Kassarjian, A., O’Brien, M. J., Andry, C., & Eustace, S. J. (2001) · Journal of Magnetic Resonance Imaging · Cited by 140
Postmortem examinations using magnetic resonance imaging: four year review of a working service
Bisset, R. A. L., Thomas, N. B., Turnbull, I. W., et al. (2002) · BMJ · doi:10.1136/bmj.324.7351.1423 · Cited by 97
Roberts, I. S. D., Benbow, E. W., Bisset, R. A. L., Jenkins, J. P. R., Lee, S. H., Reid, H., & Jackson, A. (2003) · Histopathology · doi:10.1046/j.1365-2559.2003.01614.x · Cited by 96
Self-citationReligious attitudes and the autopsy.
Geller, S. A. (1984) · PubMed · Cited by 63
A comparison of the needle biopsy post mortem with the conventional autopsy
Foroudi, F., Cheung, K., & Duflou, J. A. (1995) · Pathology · doi:10.1080/00313029500169532 · Cited by 53
Percutaneous needle autopsy sampling.
Huston, B. M., Malouf, N. N., & Azar, H. A. (1996) · PubMed · Cited by 39
Cited by
on behalf of the Association for European Cardiovascular Pathology, Basso, C., Aguilera, B., Banner, J., Cohle, S., d’Amati, G., de Gouveia, R. H., di Gioia, C., Fabre, A., Gallagher, P. J., et al. (2017) · Virchows Archiv · doi:10.1007/s00428-017-2221-0 · Cited by 568
Reimerink, J. J., van der Laan, M. J., Koelemay, M. J., Balm, R., & Legemate, D. A. (2013) · British Journal of Surgery · doi:10.1002/bjs.9235 · Cited by 327
Marijon, E., Narayanan, K., Smith, K., Barra, S., Basso, C., Blom, M. T., Crotti, L., D'Avila, A., Deo, R., Dumas, F., et al. (2023) · The Lancet · doi:10.1016/s0140-6736(23)00875-9 · Cited by 313
Post-mortem MRI versus conventional autopsy in fetuses and children: a prospective validation study
Thayyil, S., Sebire, N. J., Chitty, L. S., Wade, A., Chong, W., Olsen, O., Gunny, R. S., Offiah, A. C., Owens, C. M., Saunders, D. E., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60134-8 · Cited by 295
Semsarian, C., Ingles, J., & Wilde, A. A. M. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv063 · Cited by 284
Metadata
- Authors
- Roberts, I. S., Benamore, R. E., Benbow, E. W., Lee, S. H., Harris, J. N., Jackson, A., Mallett, S., Patankar, T., Peebles, C., Roobottom, C., & Traill, Z. C.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 379
- Issue
- 9811
- Pages
- 136-142
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2061746051
- Cited by
- 540
- References
- 11
- FWCI
- 29.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study. https://app.cochat.ai/papers/10.1016/s0140-6736(11)61483-9
- The paper
- Roberts, I. S., Benamore, R. E., Benbow, E. W., Lee, S. H., Harris, J. N., Jackson, A., Mallett, S., Patankar, T., Peebles, C., Roobottom, C., & Traill, Z. C. (2012). Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study. The Lancet. https://doi.org/10.1016/s0140-6736(11)61483-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.