Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 326

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Magnetically controlled growing rods for severe spinal curvature in young children: a prospective case series

Open access
Cheung, Kenneth Man-Chee, Cheung, Jason Pui-Yin, Samartzis, Dino, Mak, Kin-Cheung, Wong, Yat-Wa, Cheung, Wai-Yuen, Akbarnia, Behrooz A, Luk, Keith Dip-Kei·2012·The Lancet

Abstract

BACKGROUND Scoliosis in skeletally immature children is often treated by implantation of a rod to straighten the spine. Rods can be distracted (lengthened) as the spine grows, but patients need many invasive operations under general anaesthesia. Such operations are costly and associated with negative psychosocial outcomes. We assessed the effectiveness and safety of a new magnetically controlled growing rod (MCGR) for non-invasive outpatient distractions. METHODS We implanted the MCGR in five patients, two of whom have now reached 24 months' follow-up. Each patient underwent monthly outpatient distractions. We used radiography to measure the magnitude of the spinal curvature, rod distraction length, and spinal length. We assessed clinical outcome by measuring the degree of pain, function, mental health, satisfaction with treatment, and procedure-related complications. FINDINGS In the two patients with 24 months' follow-up, the mean degree of scoliosis, measured by Cobb angle, was 67° (SD 10°) before implantation and 29° (4°) at 24 months. Length of the instrumented segment of the spine increased by a mean of 1·9 mm (0·4 mm) with each distraction. Mean predicted versus actual rod distraction lengths were 2·3 mm (1·2 mm) versus 1·4 mm (0·7 mm) for patient 1, and 2·0 mm (0·2 mm) and 2·1 mm (0·7 mm) versus 1·9 mm (0·6 mm) and 1·7 mm (0·8 mm) for patient 2's right and left rods, respectively. Throughout follow-up, both patients had no pain, had good functional outcome, and were satisfied with the procedure. No MCGR-related complications were noted. INTERPRETATION The MCGR procedure can be safely and effectively used in outpatient settings, and minimises surgical scarring and psychological distress, improves quality of life, and is more cost-effective than is the traditional growing rod procedure. The technique could be used for non-invasive correction of abnormalities in other disorders. FUNDING Ellipse Technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0140-6736(12)60112-3

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 326

Metadata

Authors
Cheung, K. M.-C., Cheung, J. P.-Y., Samartzis, D., Mak, K.-C., Wong, Y.-W., Cheung, W.-Y., Akbarnia, B. A., & Luk, K. D.-K.
Venue
The Lancet
Publisher
Elsevier BV
Published
2012-05
Volume
379
Issue
9830
Pages
1967-1974
ISSN
  • 0099-5355 (ISSN-L)
  • 0140-6736
OpenAlex
W2105344739
Cited by
326
References
9
FWCI
18.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetically controlled growing rods for severe spinal curvature in young children: a prospective case series. https://app.cochat.ai/papers/10.1016/s0140-6736(12)60112-3
The paper
Cheung, K. M.-C., Cheung, J. P.-Y., Samartzis, D., Mak, K.-C., Wong, Y.-W., Cheung, W.-Y., Akbarnia, B. A., & Luk, K. D.-K. (2012). Magnetically controlled growing rods for severe spinal curvature in young children: a prospective case series. The Lancet. https://doi.org/10.1016/s0140-6736(12)60112-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.