5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial
The DOI matches its Crossref record; 22 of the 23 references it cites were found in a registry or an index.
Abstract
Background Based on the early results of the Placement of Aortic Transcatheter Valves (PARTNER) trial, transcatheter aortic valve replacement (TAVR) is an accepted treatment for patients with severe aortic stenosis who are not suitable for surgery. However, little information is available about the late clinical outcomes in such patients.Methods We did this randomised controlled trial at 21 experienced valve centres in Canada, Germany, and the USA. We enrolled patients with severe symptomatic inoperable aortic stenosis and randomly assigned (1:1) them to transfemoral TAVR or to standard treatment, which often included balloon aortic valvuloplasty. Patients and their treating physicians were not masked to treatment allocation. The randomisation was done centrally, and sites learned of the assignment only after a patient had been screened, consented, and entered into the database. The primary outcome of the trial was all-cause mortality at 1 year in the intention-to-treat population, here we present the prespecified findings after 5 years. This study is registered with ClinicalTrials.gov, number NCT00530894.Findings We screened 3015 patients, of whom 358 were enrolled (mean age 83 years, Society of Thoracic Surgeons Predicted Risk of Mortality 11·7%, 54% female). 179 were assigned to TAVR treatment and 179 were assigned to standard treatment. 20 patients crossed over from the standard treatment group and ten withdrew from study, leaving only six patients at 5 years, of whom five had aortic valve replacement treatment outside of the study. The risk of all-cause mortality at 5 years was 71·8% in the TAVR group versus 93·6% in the standard treatment group (hazard ratio 0·50, 95% CI 0·39-0·65; p<0·0001). At 5 years, 42 (86%) of 49 survivors in the TAVR group had New York Heart Association class 1 or 2 symptoms compared with three (60%) of five in the standard treatment group. Echocardiography after TAVR showed durable haemodynamic benefit (aortic valve area 1·52 cm(2) at 5 years, mean gradient 10·6 mm Hg at 5 years), with no evidence of structural valve deterioration.Interpretation TAVR is more beneficial than standard treatment for treatment of inoperable aortic stenosis. TAVR should be strongly considered for patients who are not surgical candidates for aortic valve replacement to improve their survival and functional status. Appropriate selection of patients will help to maximise the benefit of TAVR and reduce mortality from severe comorbidities.Funding Edwards Lifesciences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For patients at high or prohibitive risk of operative mortality, with surgical AVR, TAVR has been a transformative innovation, providing a life-saving treatment for patients who were previously not candidates for AVR”
From Calcific aortic stenosis (2016) · cites this paper as [222]
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationRodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Self-citationMoat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Colombo, A., Lange, R., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.001545 · Cited by 524
Vascular Complications After Transcatheter Aortic Valve Replacement
Généreux, P., Webb, J. G., Svensson, L. G., Kodali, S. K., Satler, L. F., Fearon, W. F., Davidson, C. J., Eisenhauer, A. C., Makkar, R. R., Bergman, G. W., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.003 · Cited by 518
Self-citationOutcomes Following Transcatheter Aortic Valve Replacement in the United States
Mack, M. J., Brennan, J. M., Brindis, R., Carroll, J., Edwards, F., Grover, F., Shahian, D., Tuzcu, E. M., Peterson, E. D., Rumsfeld, J. S., et al. (2013) · JAMA · doi:10.1001/jama.2013.282043 · Cited by 474
Self-citationGreen, P., Woglom, A. E., Genereux, P., Daneault, B., Paradis, J.-M., Schnell, S., Hawkey, M., Maurer, M. S., Kirtane, A. J., Kodali, S., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.06.011 · Cited by 473
Self-citationMiller, D. C., Blackstone, E. H., Mack, M. J., Svensson, L. G., Kodali, S. K., Kapadia, S., Rajeswaran, J., Anderson, W. N., Moses, J. W., Tuzcu, E. M., et al. (2012) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.01.055 · Cited by 343
Self-citation
Research works printed but not linked: 2
- Ross, 1968, Aortic stenosis, Circulation, 38, 61
- Genereux, 2012, Vascular complications after transcatheter aortic valve replacement: insights from the PARTNER (Placement of AoRTic TraNscathetER Valve) trial, J Am Coll Cardiol, 60, 1043, 10.1016/j.jacc.2012.07.003 · DOI · Paper page
Cited by
Items 401–500 of 891
Jonik, S., Marchel, M., Pędzich, E., Huczek, Z., Kochman, J., Ścisło, P., Czub, P., Wilimski, R., Hendzel, P., Opolski, G., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10225408 · Cited by 9
Balloon Aortic Valvuloplasty in the Transcatheter Aortic Valve Implantation Era
Samaja, G. (2023) · Heart International · doi:10.17925/hi.2023.17.1.13 · Cited by 9
Safety and Efficacy of Balloon Aortic Valvuloplasty Stratified by Acuity of Patient Illness
Kumar, A., Shah, R. M., Young, L. D., Patel, D. R., Bansal, A., Popović, Z., Menon, V., Kalra, A., Tuzcu, E. M., White, J., et al. (2021) · Structural Heart · doi:10.1080/24748706.2021.1954274 · Cited by 9
Self-citationWill TAVR Become the Default Treatment for Patients With Severe Aortic Stenosis?
Waksman, R., & Pichard, A. D. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.05.016 · Cited by 9
Self-citationIwata, J., Hayashida, K., Arita, R., Moriizumi, T., Kajino, A., Sakata, S., Ryuzaki, T., Shinada, K., Tsuruta, H., Yamada, Y., et al. (2025) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.31435 · Cited by 8
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Cuartas, M. M., Abreu, A., Adamo, M., Marsan, N. A., Barili, F., Bonaros, N. E., Cosyns, B., et al. (2025) · European Heart Journal - Valvular and Structural Heart Disease · doi:10.1093/ehjvshd/xwag001 · Cited by 73
Bavaria, J. E., Tommaso, C. L., Brindis, R. G., Carroll, J. D., Deeb, G. M., Feldman, T. E., Gleason, T. G., Horlick, E. M., Kavinsky, C. J., Kumbhani, D. J., et al. (2018) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.07.001 · Cited by 10
Self-citationKim, C., & Hong, M. (2019) · Korean Circulation Journal · doi:10.4070/kcj.2019.0044 · Cited by 8
Kück, K., Bleiziffer, S., Eggebrecht, H., Ensminger, S. M., Frerker, C., Möllmann, H., NEF, H. M., Thiele, H., Treede, H., Wimmer‐Greinecker, G., et al. (2020) · Zeitschrift für Herz- Thorax- und Gefäßchirurgie · doi:10.1007/s00398-020-00373-3 · Cited by 9
Moawad, K. R., Mohamed, S., Hammad, A., & Barker, T. (2024) · Heart Lung and Circulation · doi:10.1016/j.hlc.2024.02.017 · Cited by 10
Filho, A. C. B. N., Katz, M., Campos, C. M., Carvalho, L. A. F., Siqueira, D. A., Tumelero, R., Portela, A., Esteves, V. B. C., Perin, M. A., Sarmento‐Leite, R., et al. (2018) · Revista Española de Cardiología · doi:10.1016/j.recesp.2017.11.018 · Cited by 8
SAPIEN 3 Ultra — Design and procedural features of a new balloon-expandable valve
Parma, R., Hudziak, D., Smolka, G. A., Gocoł, R., Ochala, A. J., & Wojakowski, W. (2019) · Cardiology Journal · doi:10.5603/cj.a2019.0096 · Cited by 8
Evolution of Transcatheter Aortic Valve Replacement | Review of Literature
Jiang, T., Hasan, S. M., Faluk, M. A., & Patel, J. D. (2020) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2020.100600 · Cited by 8
Can Clinical Predictive Models Identify Patients Who Should Not Receive TAVR? A Systematic Review
Wessler, B. S., WEINTRAUB, A. R., Udelson, J. E., & Kent, D. M. (2020) · Structural Heart · doi:10.1080/24748706.2020.1782549 · Cited by 8
“A recent expert consensus document suggested a Society of Thoracic Surgeons Predictive Risk of Mortality (STSPROM) score >15% be used as a threshold above which TAVR might be withheld(30) based on a lack of appreciable benefit in allcause mortality at 5 years in the PARTNER IB trial.(31) We believe the rationale suppo…”
BackgroundA Decade of Transcatheter Aortic Valve Implantation in New Zealand: Growth and Inequalities
Wong, B., Armstrong, G., El‐Jack, S., & To, A. C. Y. (2020) · Heart Lung and Circulation · doi:10.1016/j.hlc.2020.08.025 · Cited by 10
Incidence and outcomes of infective endocarditis following transcatheter aortic valve implantation
Allen, C. J., Patterson, T., Chehab, O., Cahill, T. J., Prendergast, B., & Redwood, S. R. (2020) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2020.1839419 · Cited by 8
Chest radiography of contemporary trans-catheter cardiovascular devices: a pictorial essay
Ghosh, S., Abozeed, M., Saeedan, M. B., & Raman, S. V. (2020) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-20-617 · Cited by 8
“Valvular pathologies Transcatheter aortic valve devices Clinical indications Since 2002, TAVR has been validated as a suitable alternative to surgical aortic valve replacement in selected patients with severe aortic stenosis considered non-operable or intermediate- high risk for surgical repair (2,3).”
BackgroundMinimum Core Data Elements for Evaluation of TAVR
Simonato, M., Vemulapalli, S., Ben‐Yehuda, O., Wu, C., Wood, L., Popma, J. J., Feldman, T. E., Krohn, C., Hardy, K. M., Guibone, K. A., et al. (2022) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2022.01.014 · Cited by 8
Self-citationRusso, J. J., Yuen, T., Tan, J., Willson, A. B., & Gurvitch, R. (2022) · Heart Lung and Circulation · doi:10.1016/j.hlc.2022.01.007 · Cited by 8
Imaging of Bioprosthetic Valve Dysfunction after Transcatheter Aortic Valve Implantation
Alwan, L., Bernhard, B., Brugger, N., de Marchi, S. F., Praz, F., Windecker, S., Pilgrim, T., & Gräni, C. (2023) · Diagnostics · doi:10.3390/diagnostics13111908 · Cited by 9
“However, data from the PARTNER-1 trial have suggested decreased survival in this subset [21], underlining the need for early diagnosis.”
BackgroundNaser, J. A., Luis, S. A., Pislaru, S. V., Michelena, H. I., Kennedy, A. M., Eleid, M. F., Crestanello, J. A., Chebib, F. T., Pellikka, P. A., & Nkomo, V. T. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.10.014 · Cited by 7
Subclinical valve leaflet thrombosis following bioprosthetic aortic valve replacement
Giuliani, C., Zanuttini, A., Salaün, E., Côté, N., Clavel, M.-A. A., & Pîbarot, P. (2024) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000001161 · Cited by 7
What Are SAVR Indications in the TAVI Era?
Davalan, W., Ali, W. B., Mrad, S., & Noly, P. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14072357 · Cited by 9
“Bicuspid aortic valve (BAV) disease accounts for 49% of AS patients requiring SAVR [22], but only 5–10% of patients undergoing TAVI [13–15 , 23].”
All over for valve surgery for intermediate-risk patients?
Schöfer, J. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30122-2 · Cited by 7
Apical access and closure devices for transapical transcatheter heart valve procedures
Ferrari, E. (2016) · Swiss Medical Weekly · doi:10.4414/smw.2016.14237 · Cited by 9
Durability of devices: long-term results and clinical outcomes
Arsalan, M., & Mack, M. J. (2015) · EuroIntervention · doi:10.4244/eijv11swa34 · Cited by 8
Self-citationFerreira‐Neto, A. N., Gabella, T. R., Guimaraes, L. D. F. C., Freitas‐Ferraz, A. B., Bernier, M., Guimaraes, C. F., Pasian, S. G., Paradis, J., DeLarochellière, R., Dumont, É., et al. (2020) · Revista Española de Cardiología · doi:10.1016/j.recesp.2020.01.029 · Cited by 7
Mantovani, F., Clavel, M.-A. A., Potenza, A., Leuzzi, C., Grimaldi, T., Vignali, L., Navazio, A., & Guiducci, V. (2020) · Aging · doi:10.18632/aging.103862 · Cited by 7
Baumgartner, H., & Walther, T. (2018) · doi:10.1093/med/9780198784906.003.0766 · Cited by 9
Biomechanics of Transcatheter Aortic Valve Implant
Nappi, F., Singh, S. S. A., Nappi, P., & Fiore, A. (2022) · Bioengineering · doi:10.3390/bioengineering9070299 · Cited by 7
Alzu’bi, H., Rmilah, A. A. A., Haq, I.-U., Kheiri, B., Al‐Abdouh, A., Hasan, B., Elsekaily, O., Jaber, S. A., Qaisi, I., Yagmour, A., et al. (2022) · Journal of Interventional Cardiology · doi:10.1155/2022/3380605 · Cited by 7
Classical and Paradoxical Low-Flow Low-Gradient Aortic Stenosis: A Heart Failure Perspective
Garbi, M., MacCarthy, P. A., Shah, A. M., & Chambers, J. B. (2017) · Structural Heart · doi:10.1080/24748706.2017.1384876 · Cited by 7
Aortic valve replacement with pulmonary hypertension: Meta‐analysis of 70 676 patients
Rocha, R. V., Friedrich, J. O., Hong, K. L., Lee, J., Cheema, A. N., Bagai, A., Verma, S., & Yanagawa, B. (2019) · Journal of Cardiac Surgery · doi:10.1111/jocs.14309 · Cited by 7
“01).(10,36) In the PARTNER A trial, comparing TAVR to SAVR in high‐risk patients, mortality rates were similar at 30 days (3.”
ResultPercutaneous versus Surgical Intervention for Severe Aortic Valve Stenosis: A Systematic Review
Iervolino, A., Singh, S. S. A., Nappi, P., Bellomo, F., & Nappi, F. (2021) · BioMed Research International · doi:10.1155/2021/3973924 · Cited by 7
“Advocates for SAVR adduce better long-term survival with significatively lower all-cause mortality [8].”
BackgroundResultInfluentialNappi, F., Nenna, A., & Chello, M. (2022) · Bioengineering · doi:10.3390/bioengineering9060230 · Cited by 7
Operative management after transcatheter aortic valve replacement
Mazur, P. K., Cuartas, M. M., Arghami, A., Noack, T., Crestanello, J. A., & Borger, M. A. (2023) · Kardiologia Polska · doi:10.33963/kp.a2023.0026 · Cited by 8
Linke, A. H.-P., Chandrasekhar, J., Sartori, S., Lefèvre, T., BELLE, E. V., Schäfer, U., Tchétché, D., Sardella, G., Webb, J. G., Colombo, A., et al. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27154 · Cited by 9
“The PARTNER 1 trial has also demonstrated durability of BE devices and preserved 5-year outcomes for BE-TAVR compared with both SAVR and medical therapy [23,24].”
Self-citationYalta, K., Zorkun, C. S., Yılmaztepe, M. A., & Gürlertop, Y. (2018) · Indian Heart Journal · doi:10.1016/j.ihj.2018.06.015 · Cited by 7
Current Key Issues in Transcatheter Aortic Valve Replacement Undergoing a Paradigm Shift
Hwang, I., Hayashida, K., & Kim, H.-S. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0096 · Cited by 7
Wen, S., Qiao, W., Zhang, Y., & Dong, N. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2020.03.165 · Cited by 7
“Ann Transl Med 2020;8(7):449 | http://dx.”
BackgroundMultimodality evaluation of transcatheter structural valve degeneration at long-term follow-up
Ferreira‐Neto, A. N., Gabella, T. R., Guimaraes, L. D. F. C., Freitas‐Ferraz, A. B., Bernier, M., Guimaraes, C. F., Pasian, S. G., Paradis, J., DeLarochellière, R., Dumont, É., et al. (2020) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2020.02.002 · Cited by 7
Balloon aortic valvuloplasty: current status and future prospects
Dall’Ara, G., Grotti, S., Guerrieri, G., Compagnone, M., Spartà, D., Galvani, M., & Tarantino, F. F. (2022) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2022.2074837 · Cited by 7
“However, when this compensatory mechanism falters, symptoms occur and AS impacts patient quality of life and prognosis, with an average life expectancy of 2–5 years if left untreated[3].”
BackgroundRecognition of Strokes in the ICU: A Narrative Review
Noda, K., Koga, M., & Toyoda, Ḱ. (2023) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd10040182 · Cited by 8
Androshchuk, V., Chehab, O., Wilcox, J., McDonaugh, B., Montarello, N., Rajani, R., Prendergast, B., Patterson, T., & Redwood, S. R. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1506993 · Cited by 6
Takemoto, K., Myojin, T., Nishioka, Y., Soeda, T., Yamanaka, K., Nakahira, A., Nishina, T., Kawata, H., Atagi, K., Noda, T., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-90102-3 · Cited by 6
Wang, Y., Wei, L., Liu, L., Shi, J., Wang, W., Cao, T., Qin, C., Ye, J., & Guo, Y. (2025) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2025.03.036 · Cited by 6
Bhatty, A., Wilkinson, C., Aktaa, S., Batra, G., Beska, B., Khaing, P. H., Wahab, A., Raveendra, K., Taha, A., Nadarajah, R., et al. (2025) · Heart · doi:10.1136/heartjnl-2025-326045 · Cited by 7
Tikhomirov, R., Boichenko, V., Reilly-O’Donnell, B., Lucarelli, C., Srivastava, P. K., Anwar, M., Yiu, C. H. K., Dielesen, J., Noakes, V. M., Piella, S. N., et al. (2026) · Circulation Research · doi:10.1161/circresaha.125.326799 · Cited by 6
Perkutane Aortenklappenimplantation (TAVI): Aktueller Stand
Gaede, L., & Möllmann, H. (2015) · Herz · doi:10.1007/s00059-015-4328-x · Cited by 11
Subban, V., Murdoch, D. J., Savage, M. L., Crowhurst, J. A., Saireddy, R., Poon, K., Incani, A., Bett, N., Burstow, D. J., Scalia, G. M., et al. (2015) · Internal Medicine Journal · doi:10.1111/imj.12938 · Cited by 6
Podlesnikar, T., & Delgado, V. (2016) · Revista Española de Cardiología · doi:10.1016/j.recesp.2015.11.020 · Cited by 7
Transatlantic editorial on transcatheter aortic valve replacement
Thourani, V. H., Borger, M. A., Holmes, D. R., Maniar, H. S., Pinto, F. J., Miller, D. C., Rodés‐Cabau, J., Mohr, F., Schröfel, H., Moat, N. E., et al. (2017) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2017.03.047 · Cited by 6
“Among these will be discussed in more detail include ESRD,(12,35,57-61) advanced lung disease (especially if oxygen dependent),(62-64) disability or slow ambulation (6-min walk time <150 m),(54) and STS Predicted Risk of Mortality (PROM) score>15%.(8,65)”
BackgroundResultSelf-citationMacKnight, B. M., Cormican, D. S., Villablanca, P. A., Faßl, J., Nuñez-Gil, I. J., & Ramakrishna, H. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2017.02.010 · Cited by 6
Rare Cause of Severe Mitral Regurgitation after TAVI: Case Report and Literature Review
Moldovan, H., Popescu, B.-Ş., Nechifor, E., Badea, A., Ciomaga, I., Nica, C., Zaharia, O., Gheorghiță, D., Broască, M., Diaconu, C. C., et al. (2022) · Medicina · doi:10.3390/medicina58040464 · Cited by 6
Sandeep, B., Liu, X., Wu, Q., Gao, K., & Xiao, Z. (2024) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2024.102631 · Cited by 6
Five-year outcomes of transcarotid transcatheter aortic valve replacement
Portillo, J. H. D., Kalavrouziotis, D., Dumont, É., Paradis, J., Poulin, A., Beaupré, F., Avvedimento, M., Mas‐Peiró, S., Guillén, P. L. C., Mengi, S., et al. (2024) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2024.06.017 · Cited by 6
de Souza, A., Bsheish, K., Dargham, S. R., Jayyousi, A., Suwaidi, J. M. S. A., & Khalil, C. A. (2025) · Open Heart · doi:10.1136/openhrt-2024-003019 · Cited by 6
Salvage Extracorporeal Membrane Oxygenation Prior to “Bridge” Transcatheter Aortic Valve Replacement
Chiu, P., Fearon, W. F., Raleigh, L., Burdon, G., Rao, V. K., Boyd, J. H., Yeung, A. C., Miller, D. C., & Fischbein, M. P. (2016) · Journal of Cardiac Surgery · doi:10.1111/jocs.12750 · Cited by 6
“For patients at prohibitive surgical risk, transcatheter aortic valve replacement (TAVR) has been shown to improve five-year survival over medical management.(1) Among high-risk TAVR candidates with impaired ventricular function, prophylactic extracorporeal circulatory support has been used successfully.”
Self-citationWitberg, G., Finkelstein, A., Barbash, I., Assali, A., Shapira, Y., Segev, A., Halkin, A., Fefer, P., Ben‐Shoshan, J., Konigstein, M., et al. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27124 · Cited by 7
“Transcatheter aortic valve replacement (TAVR) improves survival and quality of life in patients who suffer from severe symptomatic aortic stenosis (AS) and are at high surgical risk or not surgical candidates [1]; however, the post-TAVR overall mortality rate remains high, around 25–30% at 1 year and 70–90% at 5 years…”
BackgroundBanovic, M. D., & Nikolic, S. (2017) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2017.12.001 · Cited by 6
Innovations in Transcatheter Valve Technology
Sanchez, C. E., Yakubov, S. J., & Arshi, A. (2018) · Interventional Cardiology Clinics · doi:10.1016/j.iccl.2018.06.004 · Cited by 7
Aortic Complex Rupture After Transcatheter Aortic Valve Implantation: A Clinical Case Series
Tsuru, Y., Miura, M., Shirai, S., Hayashi, M., Taninobu, K., Takiguchi, H., Ito, S., Yano, M., Kawaguchi, T., Morinaga, T., et al. (2019) · International Heart Journal · doi:10.1536/ihj.18-484 · Cited by 6
Nagaraja, V., Cohen, M. G., Suh, W., Alasnag, M. A., Généreux, P., Potts, J. E., Gunning, M., Nolan, J., Bagur, R., & Mamas, M. A. (2019) · Structural Heart · doi:10.1080/24748706.2019.1630787 · Cited by 6
Erdöl, M. A., Özbebek, Y. E., Timur, İ. E. E., Uğurlu, N., & Bozkurt, E. (2020) · Angiology · doi:10.1177/0003319720935294 · Cited by 6
“Transcatheter aortic valve replacement (TAVR) has begun to replace surgical AVR as a less invasive and life-saving treatment option in patients with moderate to high risk.(3,4) The eye offers a unique window to evaluate the vascular system.”
BackgroundContorni, F., Fineschi, M., Iadanza, A., Santoro, A., Mandoli, G. E., & Cameli, M. (2021) · Heart Failure Reviews · doi:10.1007/s10741-021-10090-0 · Cited by 6
Karaduman, B. D., Ayhan, H., Keleş, T., & Bozkurt, E. (2021) · Turkish Journal of Thoracic and Cardiovascular Surgery · doi:10.5606/tgkdc.dergisi.2021.20622 · Cited by 6
“[1] Therefore, patients with a life expectancy of <2 years due to malignancy were not included in large, randomized TAVI trials.[2-5] Advances in cancer treatment have led to improved survival; therefore, the number of cancer survivors continues to increase rapidly, as the population ages.”
BackgroundRooijakkers, M. J. P., Li, W. W. L., Stens, N. A., Vis, M. M., Tonino, P. A. L., Timmers, L., Mieghem, N. M. V., den Heijer, P., Kats, S., Stella, P. R., et al. (2022) · Netherlands Heart Journal · doi:10.1007/s12471-022-01704-9 · Cited by 6
TAVR for All? The Surgical Perspective
Zhang, X., Puehler, T., Frank, D., Sathananthan, J., Sellers, S., Meier, D. J., Both, M., Blanke, P., Seoudy, H., Saad, M. F., et al. (2022) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd9070223 · Cited by 6
“On the other hand, for THVs, longterm data are only available for patients at high surgical risk [15,53] and those receiving first-generation devices [26], limiting the applicability of those findings to lower risk and younger patients.”
BackgroundA novel balloon-expandable transcatheter aortic valve bioprosthesis: Myval and Myval Octacor
Montonati, C., Pellegrini, D., D’Atri, D. O., Pellicano, M., Briguglia, D., Giannini, F., BLASIO, G. D., Guagliumi, G., Tespili, M., & Ielasi, A. (2024) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2024.2375345 · Cited by 6
Valvular Heart Diseases - Epidemiology and New Treatment Modalities
Osorio, R. C., Souza, F. S. D. F., de Andrade, M. N., de Freitas, B. C., Durães, A. R., & Marinho, R. S. (2016) · Interventional Cardiology Journal · doi:10.21767/2471-8157.100012 · Cited by 7
Barth, A., Yücel, S., İnce, H., & Doblhammer, G. (2018) · Open Heart · doi:10.1136/openhrt-2017-000756 · Cited by 6
Rösler, Á. M., Fraportti, J., Nectoux, P., Constantin, G., Cazella, S. C., Nunes, M. R. P., & Lucchese, F. A. (2018) · Brazilian Journal of Cardiovascular Surgery · doi:10.21470/1678-9741-2018-0072 · Cited by 6
Management of Patients With Severe Aortic Stenosis With Transcatheter Valve Replacement
Dia, A., Cifu, A. S., & Shah, A. P. (2019) · JAMA · doi:10.1001/jama.2019.1336 · Cited by 6
Tzeng, Y.-H., Lee, Y., Tsao, T., Lee, K.-C., Huang, K., Hsiung, M., Wei, J., & Yin, W. (2019) · Journal of the Chinese Medical Association · doi:10.1097/jcma.0000000000000187 · Cited by 6
Ravindran, M., Henning, K. A., Qiu, F., Manoragavan, R., Dvir, D., Shuvy, M., Sud, M. K., & Wijeysundera, H. C. (2020) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2020.08.046 · Cited by 6
Effect of Aortic Valve Type on Patients Who Undergo Type A Aortic Dissection Repair
Loor, G., Gleason, T. G., Myrmel, T., Korach, A., Trimarchi, S., Desai, N. D., Bavaria, J. E., Vincentiis, C. D., Ouzounian, M., Sechtem, U. P., et al. (2021) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/j.semtcvs.2021.04.003 · Cited by 6
Sa, Y. K., Hwang, B., Chung, W., Lee, K. Y., Lee, J., Kang, D., Ko, Y., Yu, C. W., Kim, J., Choi, S., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12020571 · Cited by 6
Hurrell, H., Redwood, M., Patterson, T., & Allen, C. J. (2023) · BMJ · doi:10.1136/bmj-2022-070511 · Cited by 7
Transatlantic Editorial on transcatheter aortic valve replacement
Thourani, V. H., Borger, M. A., Holmes, D. R., Maniar, H. S., Pinto, F. J., Miller, D. C., Rodés‐Cabau, J., Mohr, F., Schröfel, H., Moat, N. E., et al. (2017) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx196 · Cited by 7
Self-citationExperimental study and early clinical application of a sutureless aortic bioprosthesis
Gomes, W. J., Leal, J. C. F., Jatene, F. B., Hossne, N. A., Gabaldi, R., Basso, G. G., Agreli, G., & Braile, D. M. (2015) · Brazilian Journal of Cardiovascular Surgery · doi:10.5935/1678-9741.20150072 · Cited by 6
“However, in recent times the transcatheter technique (TAVI) has emerged as a viable and effective alternative to treat high risk or inoperable patients([1]).”
BackgroundCautious Optimism Regarding Early Transcatheter Aortic Valve Replacement
Abdelfattah, O., Krishnaswamy, A., & Kapadia, S. R. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.122.026010 · Cited by 6
Self-citationThe Year in Cardiothoracic and Vascular Anesthesia: Selected Highlights From 2016
Ramakrishna, H., Gutsche, J. T., Patel, P. A., Evans, A. S., Weiner, M. M., Morozowich, S. T., Gordon, E. K. B., Říha, H., Bracker, J., Ghadimi, K., et al. (2016) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.10.009 · Cited by 5
Advances of surface modification to alleviate oxidative stress-induced valve degeneration
Peng, P., Hu, X., Wang, B., Wang, X., Li, S., Kang, Y., Dong, X., Yang, X., Yu, Q., & Gao, C. (2024) · Smart Materials in Medicine · doi:10.1016/j.smaim.2024.08.003 · Cited by 6
Long-Term Impact of Gender Differences After Transcatheter Aortic Valve Implantation
Iwata, J., Hayashida, K., Arita, R., Moriizumi, T., Kajino, A., Sakata, S., Ryuzaki, T., Shinada, K., Tsuruta, H., Kato, J., et al. (2024) · CJC Open · doi:10.1016/j.cjco.2024.08.012 · Cited by 5
Koo, H. J., Kang, J., Kang, D., Ahn, J., Park, D., Park, S., Kang, J., Ha, H., & Yang, D. H. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.124.037105 · Cited by 5
“1–6 Leaflet thrombosis and leaflet opening reduction has been considered as the only concern after TAVR, and studies to determine the optimal anticoagulation or antiplatelet therapy have been conducted.”
Pergola, V., Cozac, D. A., Savo, M. T., Mushtaq, S., Motta, R., Pedrinelli, R., Filardi, P. P., Sinagra, G., Amicis, M. D., Chiaruttini, M. V., et al. (2025) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2025.101720 · Cited by 6
“Significant therapeutic advancements have been made, primarily due to improved percutaneous AVR strategies, enhanced surgical techniques, and improved prosthetic valve performance and durability [17 – 19].”
Impact of Aortic Annulus Size on Outcomes After Aortic Valve Replacement
Madhavan, M. V., Mack, M. J., Pîbarot, P., Hahn, R. T., Makkar, R., Thourani, V. H., Kodali, S., Kapadia, S. R., Généreux, P., Babaliaros, V. C., et al. (2026) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2026.05.023 · Cited by 5
Self-citationMrak, M., Ambrožič, J., Mušič, Š., Terseglav, S., Kontestabile, B., Lakič, N., & Bunc, M. (2016) · Wiener klinische Wochenschrift · doi:10.1007/s00508-016-0990-0 · Cited by 5
Advances in Transcatheter Aortic Valve Replacement
Kleiman, N. S., & Reardon, M. J. (2016) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-12-1-33 · Cited by 6
Yang, R., Grober, A. F., Riojas, R. A., Ponna, V., Shunk, K., Zimmet, J. M., Gustafson, J. D., Ge, L., & Tseng, E. E. (2022) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1177/15569845221123259 · Cited by 5
PARTNERs in the future of surgical aortic valve replacement
Kappetein, A. P. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60568-2 · Cited by 7
Bagur, R., Kwok, C. S., y, L. N.-F., Ludman, P., de Belder, M., Sponga, S., Gunning, M., Nolan, J., Kiaii, B. B., Diamantouros, P., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(16)30412-0 · Cited by 5
Witberg, G., Barsheshet, A., Assali, A. R., Assa, H. V., Shaul, A. A., Orvin, K., Vaturi, M., Schwartzenberg, S., Shapira, Y., Sagie, A., et al. (2016) · Cardiology · doi:10.1159/000444007 · Cited by 6
Naganuma, T., Mitomo, S., Kin, N., & Nakamura, S. (2016) · A & A Case Reports · doi:10.1213/xaa.0000000000000373 · Cited by 5
Interventional cardiology is changing: demographic, clinical and economic considerations
Grotti, S., & Bolognese, L. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000451 · Cited by 5
Pedrazzini, G. B., Ferrari, E., Zellweger, M. J., & Genoni, M. (2017) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0037-1606356 · Cited by 5
“6 During the last few years, both the number of patients treated by transcatheter approach and the spectrum of indication rapidly expanded, leading to a repetitive update of recommendations for clinical practice [16-20].”
BackgroundMorozowich, S. T., Murray, A. W., & Ramakrishna, H. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2017.09.035 · Cited by 5
Qureshi, W., Malhotra, R., Schmidlin, E. J., Ahmed, M., Kundu, A., Hafiz, A. M., Walker, J. D., & Kakouros, N. (2020) · Academic Radiology · doi:10.1016/j.acra.2020.08.027 · Cited by 5
Anticoagulation Therapy After Transcatheter Aortic Valve Replacement
Chakravarty, T., Jilaihawi, H., de la Rosa, A., & Makkar, R. (2020) · Current Cardiology Reports · doi:10.1007/s11886-020-01425-8 · Cited by 5
Self-citationLu, Y., Yang, Y., Liu, H., Wang, W., Chen, J., Liu, S., Dong, L., Huang, L., Zhu, L., Wang, C., et al. (2022) · International Heart Journal · doi:10.1536/ihj.21-360 · Cited by 5
Metadata
- Authors
- Kapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Herrmann, H. C., Szeto, W. Y., Pichard, A. D., Williams, M. R., Fontana, G. P., Miller, D. C., Anderson, W. N., Smith, C. R., Akin, J. J., & Davidson, M. J.
- Affiliations
- Cleveland Clinic (US)
- NewYork–Presbyterian Hospital (US)
- Cedars-Sinai Medical Center (US)
- St. Paul's Hospital (CA)
- Baylor Scott & White Health (US)
- Duke Medical Center (US)
- Emory University (US)
- University of Pennsylvania (US)
- MedStar Washington Hospital Center (US)
- NYU Langone Health (US)
- Lenox Hill Hospital (US)
- Stanford Medicine (US)
- Brigham and Women's Hospital (US)
- Corresponding author
- Kapadia, Samir R
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 385
- Issue
- 9986
- Pages
- 2485-2491
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2109553540
- Cited by
- 867
- References
- 23
- Citations by year
- 2026: 37 · 2025: 53 · 2024: 39 · 2023: 55 · 2022: 50 · 2021: 70 · 2020: 84 · 2019: 94 · 2018: 107 · 2017: 118 · 2016: 114 · 2015: 40
- FWCI
- 91.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Abbott Vascular
- Medtronic
- St. Jude Medical
- National Heart, Lung, and Blood Institute (67025)
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, severe aortic stenosis, all-cause mortality, long-term outcomes, balloon aortic valvuloplasty, standard treatment, transfemoral access, NYHA functional class, aortic valve area, haemodynamic outcomes, PARTNER trial, elderly patients
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Stenosis, Canada, Cause of Death, Echocardiography, Female, Follow-Up Studies, Germany, Hemodynamics, Humans, Male, United States, Comorbidity, Survival Rate, Treatment Outcome, Risk Assessment, Stroke, Kaplan-Meier Estimate, Transcatheter Aortic Valve Replacement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.