The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Enhanced terminal room disinfection and acquisition and infection caused by multidrug-resistant organisms and Clostridium difficile (the Benefits of Enhanced Terminal Room Disinfection study): a cluster-randomised, multicentre, crossover study
Open accessAbstract
Summary Background Patients admitted to hospital can acquire multidrug-resistant organisms and Clostridium difficile from inadequately disinfected environmental surfaces. We determined the effect of three enhanced strategies for terminal room disinfection (disinfection of a room between occupying patients) on acquisition and infection due to meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, C difficile, and multidrug-resistant Acinetobacter. Methods We did a pragmatic, cluster-randomised, crossover trial at nine hospitals in the southeastern USA. Rooms from which a patient with infection or colonisation with a target organism was discharged were terminally disinfected with one of four strategies: reference (quaternary ammonium disinfectant except for C difficile, for which bleach was used); UV (quaternary ammonium disinfectant and disinfecting ultraviolet [UV-C] light except for C difficile, for which bleach and UV-C were used); bleach; and bleach and UV-C. The next patient admitted to the targeted room was considered exposed. Every strategy was used at each hospital in four consecutive 7-month periods. We randomly assigned the sequence of strategies for each hospital (1:1:1:1). The primary outcomes were the incidence of infection or colonisation with all target organisms among exposed patients and the incidence of C difficile infection among exposed patients in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT01579370. Findings 31 226 patients were exposed; 21 395 (69%) met all inclusion criteria, including 4916 in the reference group, 5178 in the UV group, 5438 in the bleach group, and 5863 in the bleach and UV group. 115 patients had the primary outcome during 22 426 exposure days in the reference group (51·3 per 10 000 exposure days). The incidence of target organisms among exposed patients was significantly lower after adding UV to standard cleaning strategies (n=76; 33·9 cases per 10 000 exposure days; relative risk [RR] 0·70, 95% CI 0·50–0·98; p=0·036). The primary outcome was not statistically lower with bleach (n=101; 41·6 cases per 10 000 exposure days; RR 0·85, 95% CI 0·69–1·04; p=0·116), or bleach and UV (n=131; 45·6 cases per 10 000 exposure days; RR 0·91, 95% CI 0·76–1·09; p=0·303) among exposed patients. Similarly, the incidence of C difficile infection among exposed patients was not changed after adding UV to cleaning with bleach (n=38 vs 36; 30·4 cases vs 31·6 cases per 10 000 exposure days; RR 1·0, 95% CI 0·57–1·75; p=0·997). Interpretation A contaminated health-care environment is an important source for acquisition of pathogens; enhanced terminal room disinfection decreases this risk. Funding US Centers for Disease Control and Prevention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magiorakos, A.-P., Srinivasan, A., Carey, R. B., Carmeli, Y., Falagas, M. E., Giske, C. G., Harbarth, S., Hindler, J. F., Kahlmeter, G., Olsson-Liljequist, B., et al. (2012) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2011.03570.x · Cited by 14,449
Adapting a clinical comorbidity index for use with ICD-9-CM administrative databases
DEYO, R. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90133-8 · Cited by 10,452
Room decontamination with UV radiation
Rutala, W. A., Gergen, M. F., & Weber, D. J. (2010) · Infection Control & Hospital Epidemiology · doi:10.1086/656244 · Cited by 221
Self-citation
Research works printed but not linked: 26
- Dancer, 2008, Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition: the case for hospital cleaning, Lancet Infect Dis, 8, 101, 10.1016/S1473-3099(07)70241-4 · DOI · Paper page
- Kramer, 2006, How long do nosocomial pathogens persist on inanimate surfaces? A systematic review, BMC Infect Dis, 6, 130, 10.1186/1471-2334-6-130 · DOI · Paper page
- Carling, 2008, Improving cleaning of the environment surrounding patients in 36 acute care hospitals, Infect Control Hosp Epidemiol, 29, 1035, 10.1086/591940 · DOI · Paper page
- Mitchell, 2015, Risk of organism acquisition from prior room occupants: a systematic review and meta-analysis, J Hosp Infect, 91, 211, 10.1016/j.jhin.2015.08.005 · DOI
- Guerrero, 2012, Acquisition of spores on gloved hands after contact with the skin of patients with Clostridium difficile infection and with environmental surfaces in their rooms, Am J Infect Control, 40, 556, 10.1016/j.ajic.2011.08.002 · DOI
- Hayden, 2008, Risk of hand or glove contamination after contact with patients colonized with vancomycin-resistant enterococcus or the colonized patients' environment, Infect Control Hosp Epidemiol, 29, 149, 10.1086/524331 · DOI · Paper page
- Stiefel, 2011, Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients, Infect Control Hosp Epidemiol, 32, 185, 10.1086/657944 · DOI
- Han, 2015, Cleaning hospital room surfaces to prevent health care-associated infections: a technical brief, Ann Intern Med, 163, 598, 10.7326/M15-1192 · DOI · Paper page
- Anderson, 2013, Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device, Infect Control Hosp Epidemiol, 34, 466, 10.1086/670215 · DOI
- Bonten, 1998, The role of “colonization pressure” in the spread of vancomycin-resistant enterococci: an important infection control variable, JAMA Intern Med, 158, 1127, 10.1001/archinte.158.10.1127 · DOI · Paper page
- Huang, 2007, Improving methicillin-resistant Staphylococcus aureus surveillance and reporting in intensive care units, J Infect Dis, 195, 330, 10.1086/510622 · DOI
- Avery, 2012, Inclusion of 30-day postdischarge detection triples the incidence of hospital-onset methicillin-resistant Staphylococcus aureus, Infect Control Hosp Epidemiol, 33, 114, 10.1086/663714 · DOI
- McDonald, 2007, Recommendations for surveillance of Clostridium difficile-associated disease, Infect Control Hosp Epidemiol, 28, 140, 10.1086/511798 · DOI · Paper page
- Eckstein, 2007, Reduction of Clostridium difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods, BMC Infect Dis, 7, 61, 10.1186/1471-2334-7-61 · DOI · Paper page
- Datta, 2011, Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants, JAMA Intern Med, 171, 491, 10.1001/archinternmed.2011.64 · DOI
- Hayden, 2006, Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures, Clin Infect Dis, 42, 1552, 10.1086/503845 · DOI · Paper page
- Smith, 2011, Assessing the efficacy of different microfibre cloths at removing surface micro-organisms associated with healthcare-associated infections, J Hosp Infect, 78, 182, 10.1016/j.jhin.2011.02.015 · DOI
- Passaretti, 2013, An evaluation of environmental decontamination with hydrogen peroxide vapor for reducing the risk of patient acquisition of multidrug-resistant organisms, Clin Infect Dis, 56, 27, 10.1093/cid/cis839 · DOI
- Haas, 2014, Implementation and impact of ultraviolet environmental disinfection in an acute care setting, Am J Infect Control, 42, 586, 10.1016/j.ajic.2013.12.013 · DOI
- Levin, 2013, The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital, Am J Infect Control, 41, 746, 10.1016/j.ajic.2013.02.010 · DOI
- Miller, 2015, Utilization and impact of a pulsed-xenon ultraviolet room disinfection system and multidisciplinary care team on Clostridium difficile in a long-term acute care facility, Am J Infect Control, 43, 1350, 10.1016/j.ajic.2015.07.029 · DOI
- Nagaraja, 2015, Clostridium difficile infections before and during use of ultraviolet disinfection, Am J Infect Control, 3, 940, 10.1016/j.ajic.2015.05.003 · DOI
- Boyce, 2011, Terminal decontamination of patient rooms using an automated mobile UV light unit, Infect Control Hosp Epidemiol, 32, 737, 10.1086/661222 · DOI
- Walker, 2012, Characterisation of Clostridium difficile hospital ward-based transmission using extensive epidemiological data and molecular typing, PLoS Med, 9, e1001172, 10.1371/journal.pmed.1001172 · DOI
- Eyre, 2013, Diverse sources of C. difficile infection identified on whole-genome sequencing, N Engl J Med, 369, 1195, 10.1056/NEJMoa1216064 · DOI · Paper page
- Grabsch, 2012, Significant reduction in vancomycin-resistant enterococcus colonization and bacteraemia after introduction of a bleach-based cleaning-disinfection programme, J Hosp Infect, 82, 234, 10.1016/j.jhin.2012.08.010 · DOI
Cited by
Chowdhary, A., Sharma, C., & Meis, J. F. (2017) · PLOS Pathogens · doi:10.1371/journal.ppat.1006290 · Cited by 750
Casini, B., Tuvo, B., Cristina, M. L., Spagnolo, A. M., Totaro, M., Baggiani, A., & Privitera, G. P. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16193572 · Cited by 185
Leistner, R., Kohlmorgen, B., Brodzinski, A., Schwab, F., Lemke, E., Zakonsky, G., & Gastmeier, P. (2023) · eClinicalMedicine · doi:10.1016/j.eclinm.2023.101958 · Cited by 48
21st Century critical care medicine: an overview
Padte, S., Samala Venkata, V., Mehta, P., Tawfeeq, S., Kashyap, R., & Surani, S. (2024) · World Journal of Critical Care Medicine · doi:10.5492/wjccm.v13.i1.90176 · Cited by 26
Metadata
- Authors
- Anderson, D. J., Chen, L. F., Weber, D. J., Moehring, R. W., Lewis, S. S., Triplett, P. F., Blocker, M., Becherer, P., Schwab, J. C., Knelson, L. P., Lokhnygina, Y., Rutala, W. A., Kanamori, H., Gergen, M. F., & Sexton, D. J.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 389
- Issue
- 10071
- Pages
- 805-814
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2576430068
- Cited by
- 357
- References
- 3
- FWCI
- 28.56
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- CDC Prevention Epicenters Program (U54CK000164, to DJS)
- NIH/NIAID (K23AI095357, to DJA)
- National Center for Advancing Translational Sciences, NIH (UL1TR001111)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.