STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 24,001–24,100 of 47,868
Lung volume measurements in infants with and without chronic lung disease
Kavvadia, V., Greenough, A., Dimitriou, G., & Itakura, Y. (1998) · European Journal of Pediatrics · doi:10.1007/s004310050823 · Cited by 17
The Effect of Preexisting Conditions on Hospital Quality Measurement for Injured Patients
Glance, L. G., Dick, A. W., Mukamel, D. B., Meredith, W. J., & Osler, T. M. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181d56770 · Cited by 17
Ito, T., Suwa, M., SAKAI, Y., Hozumi, T., & Kitaura, Y. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.07.073 · Cited by 17
González‐Haro, C., Galilea, P. A., Drobnic, F., & Escanero, J. F. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.031310 · Cited by 24
Alteration of proximal aorta biophysical properties in patients with end stage renal disease
Patrianakos, A. P., Karakitsos, D. N., de Groot, E., Parthenakis, F. I., Daphnis, E. K., & Vardas, P. E. (2005) · Heart · doi:10.1136/hrt.2004.055731 · Cited by 17
Commutability of Calibration and Control Materials for Serum Lipase
Cattozzo, G., Franzini, C., & d’Eril, G. M. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.12.2108 · Cited by 23
Dixon, C. B., & Andreacci, J. L. (2009) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b86735 · Cited by 17
TRANSMISSION OF PENILE CUFF PRESSURE TO THE PENILE URETHRA
Drinnan, M. J., Robson, W., REDDY, M., PICKARD, R. S., RAMSDEN, P. D., & Griffiths, C. J. (2001) · The Journal of Urology · doi:10.1016/s0022-5347(05)65632-7 · Cited by 17
Fruhstorfer, H., & Quarder, O. (2009) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.04.019 · Cited by 17
Shaw, N., Fraser, N. C., Rose, S.-E., Crabtree, N. J., & Boivin, C. M. (2003) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01875.x · Cited by 17
Head area measurements of dead, live, X- and Y-bearing bovine spermatozoa
Révay, T., Nagy, S. T., Kovács, A., Edvi, M. E., Hidas, A., Rens, W., & GUSTAVSSON, I. (2004) · Reproduction Fertility and Development · doi:10.1071/rd04013 · Cited by 17
Nardozza, L. M. M., Rôlo, L. C., Júnior, E. A., NOWAK, P. M., Filho, J. B., & Moron, A. F. (2010) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016340903508643 · Cited by 17
Adopting a Practical Statistical Approach for Evaluating Assay Agreement in Drug Discovery
Sun, D., Whitty, A., Papadatos, J., Newman, M. N., Donnelly, J., Bowes, S., & Josiah, S. (2005) · SLAS DISCOVERY · doi:10.1177/1087057105275725 · Cited by 17
Hartnett, M. E. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.7.991 · Cited by 17
Hernández, L., Torrella, M., Roger, N., Llunell, A., Ballester, E., Quintó, L., Serrano, M., Masa, F., & Montserrat, J. M. (2007) · CHEST Journal · doi:10.1378/chest.07-0250 · Cited by 17
McCoy, J. V., Hollenberg, S. M., Dellinger, R. P., Arnold, R. C., Ruoss, L., Lotano, V. E., Peters, P. J., Parrillo, J. E., & Trzeciak, S. W. (2009) · Resuscitation · doi:10.1016/j.resuscitation.2009.04.015 · Cited by 17
Arterial stiffness, endothelial function and microcirculatory reactivity in healthy young males
Wright, C. I., Scholten, H. J., Schilder, J. C. M., Elsen, B. M., Hanselaar, W., Kroner, C., Draijer, R., Kastelein, J. J. P., Stok, W. J., Karemaker, J. M., et al. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00807.x · Cited by 17
Assessment of passive respiratory mechanics in infants: doubleversussingle occlusion?
GOETZ, I. A., Hoo, A., Lum, S., & Stocks, J. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17304490 · Cited by 17
Fasting and post‐methionine homocysteine levels in a healthy Australian population
Silberberg, J. S., Finucane, P. M., Crooks, R., Guo, X., Fryer, J., Xie, J.-X., Wlodarczyk, J. H., Dudaman, N., & Nair, B. (1997) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1997.tb00911.x · Cited by 17
Masmas, T. N., MADSEN, H. O., Petersen, S. L., Ryder, L. P., Svejgaard, A., Alizadeh, M., & Vindeløv, L. L. (2005) · Transplantation and Cellular Therapy · doi:10.1016/j.bbmt.2005.04.004 · Cited by 21
Wilkes, A. R. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/aef231 · Cited by 17
Araújo, M. C., Ferreira, D. M., & Pereira, R. A. (2008) · Cadernos de Saúde Pública · doi:10.1590/s0102-311x2008001200006 · Cited by 29
Bispectral index is a topographically dependent variable in patients receiving propofol anaesthesia
Pandin, P., Cutsem, N. V., Tuna, T., & D'Hollander, A. A. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael235 · Cited by 20
Reliability and validity testing of an archery chronometer.
Ertan, H., Kentel, B. B., Tümer, S. T., & Korkusuz, F. (2005) · Europe PMC (PubMed Central) · Cited by 17
Type of Speech Material Affects Acceptable Noise Level Test Outcome
Koch, X., Dingemanse, G., Goedegebure, A., & Janse, E. (2016) · Frontiers in Psychology · doi:10.3389/fpsyg.2016.00186 · Cited by 19
Surgically Induced Astigmatism Assessment: Comparison Between Three Corneal Measuring Devices
Ofir, S., Abulafia, A., Kleinmann, G., Reitblat, O., & Assia, E. I. (2015) · Journal of Refractive Surgery · doi:10.3928/1081597x-20150319-04 · Cited by 17
Bland, J. M., & Altman, D. G. (1997) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329703400518 · Cited by 17
Self-citationGlavind, J., Madsen, L. D., Uldbjerg, N., & Dueholm, M. (2016) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2016.03.019 · Cited by 17
Beyond the Myths of Difference Plots
Stöckl, D. (1996) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329603300618 · Cited by 17
Carlsson, E. K., Bosaeus, I. G., & Nordgren, S. (2002) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601378 · Cited by 20
Shih, H., Hillel, Z., Declerck, C., Anagnostopoulos, C. E., Kuroda, M., & Thys, D. M. (1997) · The Journal of Clinical Monitoring · doi:10.1023/a:1007387315948 · Cited by 18
Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output
Collins, S. É., Girard, F., Boudreault, D., Chouinard, P., Normandin, L., Couture, P., Caron, M.-J., & Ruel, M. M. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03022062 · Cited by 17
Accuracy of Orbscan II in the Assessment of Posterior Curvature in Patients With Myopic LASIK
Cheng, A. C. K., Rao, S. K., & Lam, D. S. C. (2007) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20070901-06 · Cited by 17
Eicher, R., Bouchard, É., & Tremblay, A. V. (1999) · Europe PMC (PubMed Central) · Cited by 17
Work of Breathing Measurement in the Critically Ill Patient
French, C. (1999) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9902700602 · Cited by 17
Ryeng, K. A., Arnemo, J. M., & Larsen, S. E. (2001) · American Journal of Veterinary Research · doi:10.2460/ajvr.2001.62.119 · Cited by 17
Said, S. A. M., Hofman, M. B. M., Beek, A. M., van der Werf, T. S., & van Rossum, A. C. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640601015433 · Cited by 17
Donaldson‐Andersen, J., & Fitzsimmons, L. (1998) · Nutrition in Clinical Practice · doi:10.1177/088453369801300104 · Cited by 17
Giasson, C., Graham, A. D., Blouin, J.-F., Solomon, L. D., Gresset, J. A., Melillo, M., & Polse, K. A. (2005) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/01.icl.0000165286.05080.23 · Cited by 17
Rogers, J. E., Hayward, M. P., Henry, M. M., & Misiewicz, J. J. (1988) · British journal of surgery · doi:10.1002/bjs.1800751111 · Cited by 17
Baker, G., Flack, E. C., Hlavacek, A. M., Chessa, K. S., Fleming, D. M., Scheurer, M. A., & Shirali, G. S. (2006) · Congenital Heart Disease · doi:10.1111/j.1747-0803.2006.00053.x · Cited by 17
Misperceptions of body shape among university students from Germany and Lithuania
Stock, C., Küçük, N., Misevičienė, I., Petkevičienė, J., & Krämer, A. (2004) · Health Education · doi:10.1108/09654280410525559 · Cited by 25
Antonini‐Canterin, F., Pavan, D., Burelli, C., Cassin, M., Cervesato, E., & Nicolosi, G. L. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00959-0 · Cited by 17
Salivary Cotinine, Doctor-diagnosed Asthma and Respiratory Symptoms in Primary Schoolchildren
Delpisheh, A., Kelly, Y. J., Rizwan, S., & Brabin, B. J. (2007) · Maternal and Child Health Journal · doi:10.1007/s10995-007-0229-9 · Cited by 17
Prenatal Smoking and Alterations in Newborn Heart Rate During Transition
Sherman, J., Young, A., Sherman, M. P., Collazo, C., & Bernert, J. T. (2002) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1177/088421702129005326 · Cited by 17
Jegger, D., Chassot, P., Bernath, M.-A., Horisberger, J., Gersbach, P. A., Tozzi, P., Delay, D., & von Segesser, . K. (2006) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2005.12.050 · Cited by 17
Wilson, G. D., Paschoud, N., Pavy, J., Weber, K., Weber, P., Dubray, B. M., & Coucke, P. A. (1998) · British Journal of Cancer · doi:10.1038/sj.bjc.6690052 · Cited by 17
In Vivo Performance Evaluation of the Achilles Insight QUS Device
Cepollaro, C., Gonnelli, S., Montagnani, A., Caffarelli, C., Cadirni, A., Martini, S., & Nuti, R. (2005) · Journal of Clinical Densitometry · doi:10.1385/jcd:8:3:341 · Cited by 17
Angiographic 20-Year Follow-Up of 61 Consecutive Patients With Internal Thoracic Artery Grafts
Voutilainen, S., Järvinen, A., Verkkala, K. A., Keto, P. E., Heikkinen, L. O., Voutilainen, P. E. J., & Harjola, P.-T. (1999) · Annals of Surgery · doi:10.1097/00000658-199901000-00020 · Cited by 17
An acoustical guidance and position monitoring system for endotracheal tubes
Mansfield, J. P., Lyle, R. P., Voorhees, W. D., & Wodicka, G. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250590 · Cited by 17
Taylor, S. A., Slater, A., Halligan, S., Honeyfield, L., Roddie, M. E., Demeshski, J., Amin, H., & Burling, D. N. (2007) · Radiology · doi:10.1148/radiol.2421052068 · Cited by 17
Kemme, M. J. B., Faaij, R. A., Schoemaker, R. C., Kluft, C., Meijer, P., Cohen, A. F., & Burggraaf, J. (2001) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-200110000-00012 · Cited by 17
Reproducibility of ultrasonic fetal volume blood flow measurements
Brodszki, J., Gardiner, H. M., Eriksson, A., Stale, H., & Maršál, K. (1998) · Clinical Physiology · doi:10.1046/j.1365-2281.1998.00127.x · Cited by 17
Doppler flow characteristics in the assessment of pulmonary artery pressure in ductus arteriosus.
Houston, A. B., Lim, M. K., Doig, W. B., Gnanapragasam, J. P., Coleman, E. N., Jamieson, M. P. G., & Pollock, J. C. S. (1989) · Heart · doi:10.1136/hrt.62.4.284 · Cited by 17
A deterministic approach to automated stenosis quantification
Tommasini, G., Rubartelli, P., & Piaggio, M. (1999) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(199912)48:4 · Cited by 17
Precision of gestational age assessment in the neonate
Gagliardi, L., Scimone, F., DelPrete, A., Petecca, C., Stival, G., Pasinetti, G., Teani, M., Bianchi, P., Marani, M., & Duca, P. (1992) · Acta Paediatrica · doi:10.1111/j.1651-2227.1992.tb12181.x · Cited by 17
Shipstone, D., Inman, R. D., Beacock, C., & Coppinger, S. W. V. (2002) · British Journal of Urology · doi:10.1046/j.1464-410x.2002.03038.x · Cited by 17
Three-dimensional echocardiography–guided atrial septectomy: An experimental study
Suematsu, Y., Marx, G. R., Triedman, J. K., Mihaljevic, T., Mora, B. N., Takamoto, S., & del Nido, P. J. (2004) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.03.008 · Cited by 17
Air-filled microballoon manometr for use in anorectal physiology
Miller, R. C., Bartolo, D. C. C., James, D., & Mortensen, N. J. M. (1989) · British journal of surgery · doi:10.1002/bjs.1800760123 · Cited by 17
Quantification of mitral regurgitation by integrated Doppler backscatter power
MacIsaac, A. I., McDonald, I. G., Kirsner, R. L. G., Graham, S. A., & Gill, R. W. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90016-7 · Cited by 17
Gonda, K. C., Wilcke, J. R., Crisman, M. V., Ward, D. L., Robertson, J. L., Finco, D. R., & Braselton, W. E. (2003) · American Journal of Veterinary Research · doi:10.2460/ajvr.2003.64.1486 · Cited by 17
A study of the human aortic valve orifice by transesophageal echocardiography
Darmon, P.-L., Hillel, Z., Mogtader, A. H., & Thys, D. M. (1996) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(96)90063-2 · Cited by 17
Frericks, B. B., Kirchhoff, T. D., Shin, H., Stamm, G., Merkesdal, S., Abe, T., Schenk, A., Peitgen, H., Klempnauer, J. L., Galanski, M., et al. (2006) · European Radiology · doi:10.1007/s00330-006-0274-6 · Cited by 17
Harvey, S. B., Hutchison, K. M., Rennie, E., Hukins, D. W. L., & Reid, D. M. (1998) · British Journal of Radiology · doi:10.1259/bjr.71.844.9659132 · Cited by 17
Continuous Noninvasive Determination of Pulsus Paradoxus: A Pilot Study
Steele, D. W., Wright, R. O., Lee, C. M., & Jay, G. D. (1995) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1995.tb03105.x · Cited by 17
Dual-energy X-ray absorptiometry for body composition estimation in Chinese women
He, M., Li, E., & Kung, A. (1999) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600875 · Cited by 18
Wang, Z., Wei, H., Yu, Y., Sun, J., Yang, Y., Xing, G., Wu, S., Zhou, Y., Zhu, Y., Zhang, C., et al. (2004) · Journal of Molecular Biology · doi:10.1016/j.jmb.2004.08.034 · Cited by 17
Assessment of myocardial infarction in pigs using a rapid clearance blood pool contrast medium
Dewey, M., Kaufels, N., Laule, M., Schnorr, J., Wagner, S., Kivelitz, D. E., Raynaud, J., Robert, P., Hamm, B., & Taupitz, M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20046 · Cited by 17
Anderson, M. H., Simpson, I. A., Katritsis, D., Davies, M. J., & Ward, D. E. (1992) · Heart · doi:10.1136/hrt.68.9.276 · Cited by 17
Vanhove, C., Franken, P. R., Defrise, M., & Bossuyt, A. M. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1267-1 · Cited by 17
Brooks, A. J., Simpson, A., Delbridge, M. S., Beckingham, I. J., & Girling, K. J. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000141887.22660.24 · Cited by 17
Use of a Subjective Health Measure on Chinese Low Back Pain Patients in Hong Kong
Leung, A. S. L., Lam, T.-H., Hedley, A. J., & Twomey, L. T. (1999) · Spine · doi:10.1097/00007632-199905150-00006 · Cited by 19
Internal carotid artery volume flow correlates to rCBF measurements
Rothoerl, R. D., Schebesch, K.-M., Woertgen, C., & Brawanski, A. T. (2003) · Acta Neurochirurgica · doi:10.1007/s00701-003-0108-0 · Cited by 17
Weichert, F., Müller, H., Quast, U., Kraushaar, A., Spilles, P., Heintz, M., Wilke, C., von Birgelen, C., Erbel, R. M., & Wegener, D. (2003) · Medical Physics · doi:10.1118/1.1603964 · Cited by 17
Gilli, F., Hoffmann, F., Sala, A., Marnetto, F., Caldano, M., Valentino, P., Kappos, L., Bertolotto, A., & Lindberg, R. L. P. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070968 · Cited by 17
Larsen scoring of digitized X-ray images
Solymossy, C., Dixey, J., Utley, M., Gallivan, S., Young, A., Cox, N., Davies, P., Emery, P., Gough, A. S., James, D., et al. (1999) · Rheumatology · doi:10.1093/rheumatology/38.11.1127 · Cited by 17
Blood pressure measurement in adults: large cuffs for all?
Croft, P. R., & Cruickshank, J. K. (1990) · Journal of Epidemiology & Community Health · doi:10.1136/jech.44.2.170 · Cited by 17
Rhinoviruses replicate effectively at lower airway temperatures
Papadopoulos, N. G., Sanderson, G., Hunter, J., & Johnston, S. L. (1999) · Journal of Medical Virology · doi:10.1002/(sici)1096-9071(199905)58:1<44::aid-jmv6>3.0.co;2-u · Cited by 219
Horsti, J. E. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.5.940 · Cited by 17
Whole body Kt/V from dialysate urea measurements during hemodialysis.
Sternby, J. (1998) · Journal of the American Society of Nephrology · doi:10.1681/asn.v9112118 · Cited by 17
Adequacy of clinical formulae for estimation of energy requirements in children with cystic fibrosis
Reilly, J. J., Evans, T. J., Wilkinson, J., & Paton, J. Y. (1999) · Archives of Disease in Childhood · doi:10.1136/adc.81.2.120 · Cited by 17
Comparison of oscillometric and intra-arterial blood pressure and pulse measurement
Rithalia, S., & EDWARDS, D. (1994) · Journal of Medical Engineering & Technology · doi:10.3109/03091909409030249 · Cited by 17
AN EVALUATION OF THREE METHODS USED TO ASSESS GESTATIONAL AGE OF ABORIGINAL NEONATES
Sayers, S. M., & Powers, J. R. (1995) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.1995.tb00803.x · Cited by 17
(1996) · SPIE eBooks · doi:10.1117/3.pm26.ch3 · Cited by 17
van der Weerdt, A. P., Boellaard, R., Knaapen, P., Visser, C. A., Lammertsma, A. A., & Visser, F. C. (2004) · PubMed · Cited by 17
Technical Variability in Laboratory Data
Vineis, P., Schulte, P. A., & Vogt, R. F. (1993) · Elsevier eBooks · doi:10.1016/b978-0-08-092566-0.50008-2 · Cited by 17
Pressure/cross-sectional area probe in the assessment of urethral closure function
Lose, G., & Schroeder, T. V. (1990) · Urological Research · doi:10.1007/bf00302476 · Cited by 17
Reproduzierbarkeit der Goniometrie mittels spaltlampen-adaptierter optischer Koh�renztomographie
Karandish, A., Wirbelauer, C., H�berle, H., & Pham, D. T. (2004) · Der Ophthalmologe · doi:10.1007/s00347-003-0968-y · Cited by 17
van Leersum, M., Schweitzer, M. E., Gannon, F. H., Vinitski, S., Finkel, G. C., & Mitchell, D. G. (1995) · Skeletal Radiology · doi:10.1007/bf00941240 · Cited by 17
Melin, A., Obert, P., Rebocho, M., & Bonnet, P. (2002) · Journal of Toxicology and Environmental Health · doi:10.1080/00984100290071504 · Cited by 17
Fully automated computer analysis of intracolonic pressures.
Rogers, J. E., & Misiewicz, J. J. (1989) · Gut · doi:10.1136/gut.30.5.642 · Cited by 17
Evaluation of two methods for quantitation of hepatitis C virus RNA*, **
Hadziyannis, E. S., FRIED, M., & Nolte, F. S. (1997) · Molecular Diagnosis · doi:10.1016/s1084-8592(97)80009-4 · Cited by 17
A guide to clinical epidemiology for radiologists: Part II statistical analysis
Goldin, J. G., & Sayre, J. W. (1996) · Clinical Radiology · doi:10.1016/s0009-9260(96)80107-3 · Cited by 17
Segers, P., Fostier, G., Neckebroeck, J., & Verdonck, P. (1999) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(199903)46:3<380::aid-ccd27>3.0.co;2-j · Cited by 17
Body composition of Colombian women
Spurr, G., Reina, J., Li, S., Orozco, B., & Dufour, D. (1994) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/60.2.279 · Cited by 17
Bouchet, C., Spyratos, F., Hacène, K., Durcos, L., Becette, V., & Oglobine, J. (1998) · British Journal of Cancer · doi:10.1038/bjc.1998.246 · Cited by 17
Kim, W. Y., Poulsen, J. K., Terp, K., Sloth, E., & Paulsen, P. K. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70069-5 · Cited by 17
Torgerson, D. J., Donaldson, C., Garton, M. J., Russell, I. T., Westland, M., & Reid, D. M. (1994) · Osteoporosis International · doi:10.1007/bf01623061 · Cited by 17
Wong, W. W., Clarke, L. L., Johnson, G. A., Llaurador, M., & Klein, P. (1992) · Analytical Chemistry · doi:10.1021/ac00028a007 · Cited by 17
Mastrototaro, J. J., & Gross, T. M. (2003) · Diabetes Care · doi:10.2337/diacare.26.1.256 · Cited by 17
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.