Cited by 168Psychosomatic Disorders and Their TreatmentsAnxiety, Depression, Psychometrics, Treatment, Cognitive ProcessesRespiratory and Cough-Related Research

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Double-blind placebo-controlled study of the hyperventilation provocation test and the validity of the hyperventilation syndrome

Hornsveld, HK, Garssen, B, Dop, MJC Fiedeldij, van Spiegel, PI, de Haes, JCJM·1996·The Lancet

Abstract

Background Hyperventilation syndrome (HVS) describes a set of somatic and psychological symptoms thought to result from episodic or chronic hyperventilation. Recognition of symptoms during the hyperventilation provocation test (HVPT) is the most widely used criterion for diagnosis of HVS. We have investigated the validity of the HVPT and of the concept of HVS. Methods In a randomised, double-blind, crossover design, the ability of 115 patients with suspected HVS to recognise symptoms during the HVPT was compared with the ability to recognise symptoms during a placebo test (isocapnic overbreathing, with carbon dioxide levels maintained by manual titration). 30 patients who had positive results on the HVPT underwent ambulatory transcutaneous monitoring of pCO2 to ascertain whether they hyperventilated during spontaneous symptom attacks. Findings Of the 115 patients who underwent the HVPT and the placebo test, 85 (74%) reported symptom recognition during the HVPT (positive diagnosis HVS). Of that subset, 56 were also positive on the placebo test (false-positive), and 29 were negative on the placebo test (true-positive). False-positive and true-positive patients did not differ in symptom profile or in physiological variables. During ambulatory monitoring (15 true-positive, 15 false-positive) 22 attacks were registered. Transcutaneous end-tidal, pCO2 decreased during only seven. The decreases were slight and apparently followed the onset of the attack, which suggests that hyperven…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0140-6736(96)02024-7

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Research works printed but not linked: 1

  1. Garssen, 1994, Ambulatory measurement of transcutaneous PCO2, J Psychophysiol, 8, 231

Cited by

Sorted by citations

Items 101–168 of 168

Metadata

Authors
Hornsveld, H., Garssen, B., Dop, M. F., van Spiegel, P., & de Haes, J.
Affiliations
  • Amsterdam UMC Location University of Amsterdam (NL)
  • Slotervaartziekenhuis (NL)
Venue
The Lancet
Publisher
Elsevier BV
Published
1996-07
Volume
348
Issue
9021
Pages
154-158
ISSN
  • 0099-5355 (ISSN-L)
  • 0140-6736
OpenAlex
W2102303952
Cited by
168
References
34
Citations by year
2026: 4 · 2025: 2 · 2024: 1 · 2023: 6 · 2022: 7 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 4 · 2016: 4 · 2015: 4 · 2014: 6 · 2013: 6 · 2012: 8
FWCI
6.58
Type
journal article
Language
en
Open access
closed
Locations
  • The Lancet (publishedVersion)
  • PubMed (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion)
Topics
  • Health Sciences › Medicine › Psychiatry and Mental health › Psychosomatic Disorders and Their Treatments
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Anxiety, Depression, Psychometrics, Treatment, Cognitive Processes
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory and Cough-Related Research
Keywords
hyperventilation syndrome, diagnostic validity, false-positive diagnosis, transcutaneous carbon dioxide monitoring, end-tidal PCO2, hyperventilation, symptom recognition, ambulatory monitoring
MeSH terms
Adult, Blood Gas Monitoring, Transcutaneous, Double-Blind Method, False Positive Reactions, Female, Humans, Hyperventilation, Male, Reproducibility of Results, Case-Control Studies, Cross-Over Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review