The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Formation and characteristics of the apatite layer on plasma-sprayed hydroxyapatite coatings in simulated body fluid
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioceramics: From Concept to Clinic
Hench, L. L. (1991) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1991.tb07132.x · Cited by 4,977
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Microelectrode studies on the acid microenvironment beneath adherent macrophages and osteoclasts*1
SILVER, I. (1988) · Experimental Cell Research · doi:10.1016/0014-4827(88)90191-7 · Cited by 896
Ca, P‐rich layer formed on high‐strength bioactive glass‐ceramic A‐W
Kokubo, T., Ito, S., Huang, Z. T., Hayashi, T., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240306 · Cited by 859
Rey, C., Collins, B., Goehl, T., Dickson, I. R., & Glimcher, M. J. (1989) · Calcified Tissue International · doi:10.1007/bf02556059 · Cited by 671
Radin, S. R., & Ducheyne, P. (1992) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00702942 · Cited by 298
Chemical reaction of bioactive glass and glass-ceramics with a simulated body fluid
Kokubo, T., Kushitani, H., Ohtsuki, C., Sakka, S., & Yamamuro, T. (1992) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00705272 · Cited by 269
A calcium hydroxyapatite precipitated from an aqueous solution
Arends, J., Christoffersen, J., Christoffersen, M. R., Eckert, H., Fowler, B. O., Heughebaert, J. C., Nancollas, G. H., Yesinowski, J. P., & Zawacki, S. J. (1987) · Journal of Crystal Growth · doi:10.1016/0022-0248(87)90284-3 · Cited by 248
The Formation and Properties of Precipitates
Walton, A. G. (1979) · Medical Entomology and Zoology · Cited by 242
Crystal growth of calcium phosphates in the presence of magnesium ions
Salimi, M. H., Heughebaert, J. C., & Nancollas, G. H. (1985) · Langmuir · doi:10.1021/la00061a019 · Cited by 237
Cited by
TiO2 nanotubes: Self-organized electrochemical formation, properties and applications
Macak, J. M., Tsuchiya, H., Ghicov, A., Yasuda, K., Hahn, R., Bauer, S., & Schmuki, P. (2007) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2007.08.004 · Cited by 1,415
Material fundamentals and clinical performance of plasma‐sprayed hydroxyapatite coatings: A review
Sun, L., Berndt, C. C., Gross, K. A., & Kucuk, A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1056 · Cited by 1,065
Ghicov, A., & Schmuki, P. (2009) · Chemical Communications · doi:10.1039/b822726h · Cited by 867
Porter, A. E., Patel, N., Skepper, J. N., Best, S. M., & Bonfield, W. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00355-7 · Cited by 412
Xin, Y., Huo, K., Tao, H., Tang, G., & Chu, P. K. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.05.014 · Cited by 408
Metadata
- Authors
- Weng, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1997-08
- Volume
- 18
- Issue
- 15
- Pages
- 1027-1035
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2109784607
- Cited by
- 266
- References
- 18
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formation and characteristics of the apatite layer on plasma-sprayed hydroxyapatite coatings in simulated body fluid. https://app.cochat.ai/papers/10.1016/s0142-9612(97)00022-7
- The paper
- Weng, J. (1997). Formation and characteristics of the apatite layer on plasma-sprayed hydroxyapatite coatings in simulated body fluid. Biomaterials. https://doi.org/10.1016/s0142-9612(97)00022-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.