Light-induced tailoring of PEG-hydrogel properties
Abstract
We have previously reported (Andreopoulos et al. J Am Chem Soc 118 (1996) 6235-6240) the synthesis of hydrogels via the photopolymerization of water-soluble PEG molecules. In this paper, PEG-hydrogel membranes were prepared by the irradiation (> 300 nm) of aqueous solutions of photosensitive 4-armed PEG (nominal molecular weight of 20000), in the absence of photo-initiators. The hydroxyl termini of the PEG's were functionalized with cinnamylidene acetate groups to form photosensitive PEG macromers (PEG-CA), which upon irradiation (>300 nm) formed crosslinks between adjacent cinnamylidene groups resulting in highly crosslinked networks (hydrogels) (Andreopoulos et al. J Am Chem Soc 118 (1996) 6235-6240). The hydrogel membranes were highly swellable with equilibrium volume fractions ranging from 0.02 to 0.05. Their swellability was a function of irradiation light (>300 nm) and degree of modification of the PEG molecules. The effect of light on the permeation fluxes of myoglobin (Mb), hemoglobin (Hb), and lactate dehydrogenase-L (LDH) through PEG membranes was also assessed and the diffusion coefficients of the proteins were determined accordingly. The PEG-CA membranes exhibited photoscissive behavior upon exposure to UV irradiation (254 nm). Therefore, UV light was used as a trigger to control the mesh size of the membranes, and thereby the permeation fluxes of Mb, Hb, and LDH. Equilibrium swelling experiments with membranes prepared under different irradiation conditions were performed, and the Flory-Huggins model was utilized to determine the mesh size and the average molecular weight between crosslinks of the synthesized hydrogels.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Lendlein et al. prepared two photo-responsive polymers with cinnamic acid and cinamylidene acetic acid terminal as the photoreversible switch.
“Lendlein et al. [91,420] prepared two photo-responsive polymers with cinnamic acid and cinamylidene acetic acid terminal as the photoreversible switch.”
From A review of stimuli-responsive shape memory polymer composites (2013) · cites this paper as [420]
The citation lists haven’t been fetched yet
References 6 · Cited by 127
- Authors
- Andreopoulos, F. M., Beckman, E. J., & Russell, A. J.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Russell, Alan J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1998-08
- Volume
- 19
- Issue
- 15
- Pages
- 1343-1352
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2069508413
- Cited by
- 127
- References
- 6
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 5 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 4 · 2018: 6 · 2017: 4 · 2016: 10 · 2015: 5 · 2014: 8 · 2013: 11 · 2012: 7
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Purdue University
- University of Pittsburgh
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Physical Sciences › Chemistry › Organic Chemistry › Photopolymerization techniques and applications
- Physical Sciences › Chemistry › Organic Chemistry › Advanced Polymer Synthesis and Characterization
- Keywords
- poly(ethylene glycol) hydrogels, UV crosslinking, hydrogel swelling, protein permeation, myoglobin, hemoglobin, lactate dehydrogenase, protein diffusion coefficient, Flory-Huggins theory, crosslink density, biomaterial membranes
- MeSH terms
- Diffusion, Kinetics, Light, Mathematical Computing, Membranes, Artificial, Molecular Weight, Photochemistry, Polyethylene Glycols, Proteins, Ultraviolet Rays, Hydrogels
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review