Effects of hydroxylapatite coating crystallinity on biosolubility, cell attachment efficiency and proliferation in vitro
Open accessThe DOI matches its Crossref record.
Abstract
A hydroxylapatite (HA) coating with approximately 97% crystalline HA content (MP-1 treated HA coating, MP-HA) was tested in vitro for its biosolubility and cellular biocompatibility. The MP-HA coating was compared with a standard HA coating with approximately 63% crystallinity (SHA) and an amorphous HA coating with approximately 25% crystallinity (AHA), as well as a titanium (Ti) surface without HA coating as a control. The topographic study with scanning electron microscopy indicated that MP-HA appeared more coarse, with projected nodules which altered the shape of cells attached to the substrate. Biosolubility study indicated that MP-HA had the least effect on the culture medium pH, while AHA (P < 0.01) and SHA (P < 0.05) significantly raised the medium pH up to 8.2 and 7.75, respectively. X-ray diffraction (XRD) analysis showed essentially unchanged levels of the total soluble phases of all coatings after incubation with culture medium, except that the CaO phase was rapidly dissolved from AHA coatings and completely eliminated from SHA coatings. Cultures of human gingival fibroblasts on these HA coatings showed that MP-HA and SHA had about the same cell attachment efficiency which was relatively lower than that of AHA coatings. MP-HA generated significant higher cell proliferation rate relative to AHA (P < 0.01) and SHA (P < 0.05). This study indicated that surface chemistry and topography of lower crystallinity might be favorable to cell attachment, but that elevated medium pH might result in a cytotoxic effect that inhibits the proliferation of attached cells on coating surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calcium phosphates as substitution of bone tissues
VALLETREGI, M. (2004) · Progress in Solid State Chemistry · doi:10.1016/j.progsolidstchem.2004.07.001 · Cited by 1,160
Paital, S. R., & Dahotre, N. B. (2009) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2009.05.001 · Cited by 673
Water‐Stable Silk Films with Reduced β‐Sheet Content
Jin, H. ‐., Park, J., Karageorgiou, V., Kim, U. ‐., Valluzzi, R., Cebe, P., & Kaplan, D. L. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400405 · Cited by 614
Size effect of hydroxyapatite nanoparticles on proliferation and apoptosis of osteoblast-like cells
SHI, Z., HUANG, X., CAI, Y., TANG, R., & YANG, D. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.023 · Cited by 476
Peter, M., Ganesh, N., Selvamurugan, N., Nair, S. V., Furuike, T., Tamura, H., & Jayakumar, R. (2010) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2009.11.050 · Cited by 373
Thermal spraying of biomaterials
Heimann, R. B. (2006) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2006.04.052 · Cited by 248
Biocompatibility and nanostructured materials: applications in nanomedicine
Adabi, M., Naghibzadeh, M., Adabi, M., Zarrinfard, M. A., Esnaashari, S. S., Seifalian, A. M., Faridi-Majidi, R., Tanimowo Aiyelabegan, H., & Ghanbari, H. (2017) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2016.1178134 · Cited by 244
“…in clinical applications Many factors could potentially influence material’s biocompatibility and toxicity including their surface chemistry (Chou et al. 1999, Tsai et al. 2001), roughness (Campoccia et al. 2003), surface energy (hyrophobicity/hydrophilicity) (Cai et al. 2002), the level…”
BackgroundAnodic plasma-chemical treatment of CP titanium surfaces for biomedical applications
Frauchiger, V. M., Schlottig, F., Gasser, B., & Textor, M. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00560-x · Cited by 200
“Providing the bone–implant interface with a locally increased mineral content is believed to result in a microenvironment that fosters fast neobone formation and ingrowth [22–24].”
BackgroundGandolfi, M. G., Ciapetti, G., Taddei, P., Perut, F., Tinti, A., Cardoso, M. V., Van Meerbeek, B., & Prati, C. (2010) · Dental Materials · doi:10.1016/j.dental.2010.06.002 · Cited by 192
“[41] Chou L, Marek B, Wagner WR.”
BackgroundHu, Q., Tan, Z., Liu, Y., Tao, J., Cai, Y., Zhang, M., Pan, H., Xu, X., & Tang, R. (2007) · Journal of Materials Chemistry · doi:10.1039/b710936a · Cited by 188
Nanofiber Scaffolds with Gradients in Mineral Content for Spatial Control of Osteogenesis
Liu, W., Lipner, J., Xie, J., Manning, C. N., Thomopoulos, S., & Xia, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am405418g · Cited by 182
Oliveira, A. L., Alves, C. M., & Reis, R. L. (2002) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1021106525097 · Cited by 33
Metadata
- Authors
- Chou, L., Marek, B., & Wagner, W. R.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 20
- Issue
- 10
- Pages
- 977-985
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2088935167
- Cited by
- 203
- References
- 0
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.