CoChat

Ozonation and UV irradiation—an introduction and examples of current applications

Open access
Summerfelt, Steven T. · 2003 · Aquacultural Engineering

The DOI matches its Crossref record; 31 of the 34 references it cites were found in a registry or an index.

Abstract

This paper was written to introduce the 2001 AES Issues Forum's ‘Ozone and UV Treatment’ session by providing an overview of ozone and ultraviolet (UV) irradiation technologies as well as several examples of current ozone and UV irradiation applications in aquaculture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0144-8609(02)00069-9

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 An ozone/oxygen feed gas is injected into water within three Speece cones (plumbed in parallel for redundancy and v ariable flow requirements). The system shown is used to disinfect 400  /2400 l/min of surface water at the US Fish and Wildlife Ser v ice's Northeast Fishery Center in Lamar, PA (Summerfelt et al., in press).
Fig. 1 An ozone/oxygen feed gas is injected into water within three Speece cones (plumbed in parallel for redundancy and v ariable flow requirements). The system shown is used to disinfect 400  /2400 l/min of surface water at the US Fish and Wildlife Ser v ice's Northeast Fishery Center in Lamar, PA (Summerfelt et al., in press).CC-BY-NC-ND · From the PDF
Fig. 2 A copper pipe is used to supply the pure oxygen feed gas to a LHO unit, while a stainless steel pipe is used to carry the ozonated feed gas. The LHO is used to oxygenate/ozonate 4800 l/min of water in a recirculating system at the Conser v ation Fund Freshwater Institute (Shepherdstown, WV).
Fig. 2 A copper pipe is used to supply the pure oxygen feed gas to a LHO unit, while a stainless steel pipe is used to carry the ozonated feed gas. The LHO is used to oxygenate/ozonate 4800 l/min of water in a recirculating system at the Conser v ation Fund Freshwater Institute (Shepherdstown, WV).CC-BY-NC-ND · From the PDF
Fig. 3 The 4800 l/min recirculating system at the Freshwater Institute was designed for ozone addition within the purified oxygen feed gas supplied to the LHO unit. Drawing courtesy of Marine Biotech, Inc. (Be v erly, MA).
Fig. 3 The 4800 l/min recirculating system at the Freshwater Institute was designed for ozone addition within the purified oxygen feed gas supplied to the LHO unit. Drawing courtesy of Marine Biotech, Inc. (Be v erly, MA).CC-BY-NC-ND · From the PDF
Fig. 4 Ozone Treatment system for disinfecting 400  /2400 l/min of surface water at the US Fish and Wildlife Ser v ice's Northeast Fishery Center in Lamar, PA (Summerfelt et al., in press). Drawing courtesy of Oak Point Associates, Biddeford, ME.
Fig. 4 Ozone Treatment system for disinfecting 400  /2400 l/min of surface water at the US Fish and Wildlife Ser v ice's Northeast Fishery Center in Lamar, PA (Summerfelt et al., in press). Drawing courtesy of Oak Point Associates, Biddeford, ME.CC-BY-NC-ND · From the PDF
Fig. 5 Nearly monochromatic irradiation specific to the 254 nm wa v elength can be supplied by low pressure UV bulb systems (Courtesy of Trojan Technologies, London, Ont., Canada).
Fig. 5 Nearly monochromatic irradiation specific to the 254 nm wa v elength can be supplied by low pressure UV bulb systems (Courtesy of Trojan Technologies, London, Ont., Canada).CC-BY-NC-ND · From the PDF
Fig. 6 Medium pressure bulb systems supply a broader UV spectrum (Courtesy of Trojan Technologies, London, Ont., Canada).
Fig. 6 Medium pressure bulb systems supply a broader UV spectrum (Courtesy of Trojan Technologies, London, Ont., Canada).CC-BY-NC-ND · From the PDF
Fig. 7 Quartz slee v es are cleaned on an open channel UV system (with low pressure/low intensity bulbs) at the Freshwater Institute.
Fig. 7 Quartz slee v es are cleaned on an open channel UV system (with low pressure/low intensity bulbs) at the Freshwater Institute.CC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Research works printed but not linked: 9

  1. Blogoslawski, W.J., Perez, C., 1992. Ozone treatment of seawater to control vibriosis in mariculture of penaeid shrimp, Penaeus vannameii. in: Blogoslawski, W.J. (ed.), Proceedings of the Third International Symposium on the Use of Ozone in Aquatic Systems. Pan American Group of the International Ozone Association, Stamford, CT, pp. 123 Á/133.
  2. Brazil, B.L., 1996. Impact of ozonation on system performance and growth characteristics of hybrid striped bass (Morone chrysops XM. saxatilis ) and tilapia hybrids (Sarotherodon sp.) reared in recirculating aquaculture systems. Ph.D. Dissertation, Virginia Polytechnic Institute and State University, Blacksburg, VA.
  3. Crecelius, E.A., 1978. The production of bromine and bromate in seawater by ozonation. Proceedings of the Symposium on Advanced Ozone Technology. International Ozone Institute, Norwalk, CT.
  4. Hemdal, J.F., 1992. Reduction of ozone oxidants in synthetic seawater by use of sodium thiosulfate. Progressive Fish-Culturist 54, 54 Á/56. · doi:10.1577/1548-8640(1992)054
  5. Hunter, G.L., O'Brien, W.J., Hulsey, R.A., Carns, K.E., Ehrhard, R., 1998. Emerging disinfection technologies: medium-pressure ultraviolet lamps and other systems are considered for wastewater applications. Water Environment and Technology 10 (6), 40 Á/44.
  6. Keaffaber, J.J., Coston, C.J., Ham, W.G., Burns, T., Sherrill, A., Khan, S., 1992. Redox chemistry of closed ozonated systems: Modeling bromine and other redox active species. in: Blogoslawski W.J. (ed.), Proceedings of the Third International Symposium on the Use of Ozone in Aquatic Systems. Pan American Group of the International Ozone Association, Stamford, CT, pp. 76 Á/91.
  7. Rodriguez, J., Gagnon, S., 1991. Disinfection: liquid purification by UV radiation, and its many applications. Ultrapure Water 8 (6), 26 Á/31.
  8. Summerfelt, S.T., Hochheimer, J.N., 1997. Review of ozone processes and applications as an oxidizing agent in aquaculture. The Progressive Fish-Culturist 59, 94 Á/105. · doi:10.1577/1548-8640(1997)059
  9. Summerfelt, S.T., Bebak-Williams, J., Fletcher, J., Carta, A., Creaser, D. Description of the surface water filtration and ozone treatment system at the Northeast Fishery Center. Fisheries Bioengineering Symposium IV. American Fisheries Society, Bethesda, MD, in press.

Cited by

See all 240

Metadata

Authors
Summerfelt, S. T.
Affiliations
The Conservation Fund (US)
Corresponding author
Summerfelt, Steven T.
Venue
Aquacultural Engineering
Publisher
Elsevier BV
Published
2003-06
Volume
28
Issue
1-2
Pages
21-36
ISSN
0144-8609 (ISSN-L)
OpenAlex
W2152618715
Cited by
228
References
34
Citations by year
2026: 11 · 2025: 16 · 2024: 11 · 2023: 15 · 2022: 11 · 2021: 9 · 2020: 20 · 2019: 14 · 2018: 24 · 2017: 10 · 2016: 4 · 2015: 8 · 2014: 13 · 2013: 10 · 2012: 7
FWCI
2.09
Type
journal article
Language
en
Open access
Licence
Locations
Aquacultural Engineering (publishedVersion, cc-by-nc-nd)
Funders
  • U.S. Department of Agriculture
  • U.S. Fish and Wildlife Service
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
  • Life Sciences › Immunology and Microbiology › Immunology › Aquaculture disease management and microbiota
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biotechnology › Microbial Inactivation Methods
Keywords
ozonation, UV irradiation, UV treatment, aquaculture, water treatment, disinfection, water quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.