The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Intraobserver and Interobserver Agreement in Measurement of Optic Disc Characteristics
Open accessAbstract
Reliable measures of optic nerve status are important parameters for epidemiologic and clinical studies of glaucoma. Stereo fundus photography has been used to reduce interobserver variation, but little data have been reported quantifying the level of agreement in these situations. This article examines chance-corrected intraobserver and interobserver agreement for horizontal and vertical cup:disc ratios and width of the narrowest remaining neuroretinal rim on stereo, color, fundus photographs. Intraobserver agreement was substantial to almost perfect for both readers (kappas between 0.82 and 0.86 for horizontal and vertical cup:disc ratios and 0.71 for the neuroretinal rim). Interobserver agreement was also substantial (kappas of 0.71 for horizontal cup:disc ratio, 0.74 for vertical cup:disc ratio, and 0.58 for the neuroretinal rim). Both intraobserver and interobserver agreement were best for glaucoma patients followed by ocular hypertensives and controls. Dichotimizing cup:disc ratios into suspicious or not suspicious using a range of cutoff points (greater than or equal to 0.5, greater than or equal to 0.6, and greater than or equal to 0.7 disc diameters [DD]) had little effect on agreement levels. Estimation of the status of the optic nerve is complex, requiring judgment about the shape and structure of the cup. Agreement is optimized by using stereo photographs, using the same observer and, when evaluating progression, comparing photographs from different points in time at a single sitting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Statistical principles in experimental design.
Winer, B. J. (1962) · McGraw-Hill Book Company · doi:10.1037/11774-000 · Cited by 26,755
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Statistical Methods for Rates and Proportions.
Everitt, B. S., & Fleiss, J. L. (1981) · Biometrics · doi:10.2307/2530193 · Cited by 8,990
Statistical Principles in Experimental Design
Myers, J. L., & Winer, B. J. (1964) · The American Journal of Psychology · doi:10.2307/1419292 · Cited by 8,058
Statistical Methods for Rates and Proportions, 2nd ed
GROVE, W. A. (1981) · American Journal of Psychiatry · doi:10.1176/ajp.138.12.1644-a · Cited by 3,748
Fleiss, J. L., & Cohen, J. (1973) · Educational and Psychological Measurement · doi:10.1177/001316447303300309 · Cited by 3,354
Variability of expert observers in evaluating the optic disc.
Lichter, P. R. (1976) · Europe PMC (PubMed Central) · Cited by 306
Evaluation of Nerve Fiber Layer Assessment
Sommer, A., Quigley, H. A., Robin, A. L., Miller, N. R., Katz, J., & Arkell, S. (1984) · Archives of Ophthalmology · doi:10.1001/archopht.1984.01040031430017 · Cited by 213
Self-citationNeuroretinal Rim Area in Early Glaucoma
Airaksinen, P. J., Drance, S. M., & Schulzer, M. (1985) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75856-8 · Cited by 157
Cited by
The number of people with glaucoma worldwide in 2010 and 2020
Quigley, H. A. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.081224 · Cited by 7,394
Self-citationOptical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Medeiros, F. A., Zangwill, L. M., Bowd, C., Vessani, R. M., Susanna, R., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.08.069 · Cited by 649
Optical coherence tomography to detect and manage retinal disease and glaucoma
Jaffe, G. J., & Caprioli, J. (2004) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00792-x · Cited by 505
Metadata
- Authors
- Tielsch, J. M., Katz, J., Quigley, H. A., Miller, N. R., & Sommer, A.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1988-03
- Volume
- 95
- Issue
- 3
- Pages
- 350-356
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2034316608
- Cited by
- 274
- References
- 14
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraobserver and Interobserver Agreement in Measurement of Optic Disc Characteristics. https://app.cochat.ai/papers/10.1016/s0161-6420(88)33177-5
- The paper
- Tielsch, J. M., Katz, J., Quigley, H. A., Miller, N. R., & Sommer, A. (1988). Intraobserver and Interobserver Agreement in Measurement of Optic Disc Characteristics. Ophthalmology. https://doi.org/10.1016/s0161-6420(88)33177-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.