Frequency of Adverse Systemic Reactions after Fluorescein Angiography
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Intravenous fluorescein angiography is a commonly performed and extraordinarily valuable diagnostic procedure. The frequency of adverse reactions after angiography has varied considerably in previous reports. In a prospective study of 2789 angiographic procedures in 2025 patients, the authors found that the percentage of adverse reactions depended strongly on the patient's angiographic history. Overall, adverse reactions followed 4.8% of the angiographic procedures. These reactions included nausea (2.9%), vomiting (1.2%), flushing/itching/hives (0.5%), and other reactions (dyspnea, syncope, excessive sneezing) (0.2%). No cases of anaphylaxis, myocardial infarction, pulmonary edema, or seizures occurred. The percentage of reactions was 1.8% for patients who had had previous angiography without ever having had an adverse reaction. In contrast, the percentage of reactions was 48.6% for patients who had had an adverse reaction to angiography previously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Method of Photographing Fluorescence in Circulating Blood in the Human Retina
NOVOTNY, H. R., & ALVIS, D. L. (1961) · Circulation · doi:10.1161/01.cir.24.1.82 · Cited by 698
Fluorescein Angiography Complication Survey
Yannuzzi, L. A., Rohrer, K. T., Tindel, L. J., Sobel, R. S., Costanza, M. A., Shields, W., & Zang, E. (1986) · Ophthalmology · doi:10.1016/s0161-6420(86)33697-2 · Cited by 606
Model Robust Confidence Intervals Using Maximum Likelihood Estimators
Royall, R. M. (1986) · International Statistical Review / Revue Internationale de Statistique · doi:10.2307/1403146 · Cited by 578
Madowitz, J. S. (1979) · JAMA · doi:10.1001/jama.241.26.2813 · Cited by 65
Cardiac Arrest Following Fluorescein Angiography
Cunningham, E. E., & Balu, V. (1979) · JAMA · doi:10.1001/jama.1979.03300220043023 · Cited by 20
Cited by
A review of optical coherence tomography angiography (OCTA)
de Carlo, T. E., Romano, A., Waheed, N. K., & Duker, J. S. (2015) · International Journal of Retina and Vitreous · doi:10.1186/s40942-015-0005-8 · Cited by 1,126
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Optical Coherence Tomography Angiography in Diabetic Retinopathy: A Prospective Pilot Study
Ishibazawa, A., Nagaoka, T., Takahashi, A., Omae, T., Tani, T., Sogawa, K., Yokota, H., & Yoshida, A. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.021 · Cited by 617
Agemy, S. A., Scripsema, N. K., Shah, C. M., Chui, T., Garcia, P. M., Lee, J. G., Gentile, R. C., Hsiao, Y.-S., Zhou, Q., Ko, T., et al. (2015) · Retina · doi:10.1097/iae.0000000000000862 · Cited by 472
Spectral-Domain Optical Coherence Tomography Angiography of Choroidal Neovascularization
de Carlo, T. E., Bonini Filho, M. A., Chin, A. T., Adhi, M., Ferrara, D., Baumal, C. R., Witkin, A. J., Reichel, E., Duker, J. S., & Waheed, N. K. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.01.029 · Cited by 394
Metadata
- Authors
- Kwiterovich, K. A., Maguire, M. G., Murphy, R. P., Schachat, A. P., Bressler, N. M., Bressler, S. B., & Fine, S. L.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1991-07
- Volume
- 98
- Issue
- 7
- Pages
- 1139-1142
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W1269764409
- Cited by
- 353
- References
- 5
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.