Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 188

The DOI matches its Crossref record.

Diode Laser Photocoagulation for Threshold Retinopathy of Prematurity

Open access
Hunter, David G., Repka, Michael X. · 1993 · Ophthalmology

Abstract

BACKGROUND: Although peripheral cryotherapy decreases the incidence of unfavorable anatomic outcomes in threshold retinopathy of prematurity (ROP), apnea, bradycardia, and lid edema can occur. Argon laser indirect ophthalmoscope photocoagulation has been used as an alternative to cryotherapy, with fewer adverse effects. Retinal lesions placed with diode lasers are deeper than similar argon laser lesions, and it is not known whether this difference could influence the response to ablative therapy. METHODS: Patients were enrolled under a prospective, randomized protocol. One eye of each patient with symmetric, threshold ROP was treated with an 814/815 nm diode laser, while the other eye was treated with cryotherapy. Patients with asymmetric diseases also were randomized for treatment in the threshold eye. RESULTS: Nineteen infants (33 eyes) were treated, ranging from 485 to 863 g birth weight (23 to 27 weeks gestational age); 18 patients (32 eyes) were followed for 3 months or longer. Four patients (8 eyes) had bilateral zone 1 disease. Postconceptional age was 36 to 45 weeks at the time of treatment. The diode laser treatment was better tolerated than cryotherapy, and the treatment apparatus was more easily transported. Apneic episodes requiring intubation resulted from two cryotherapy sessions but no diode laser sessions. Five cryotherapy-treated eyes required retreatment because of persistent disease with adjacent skip areas. In the group followed for 3 to 15 months, 1 cryotherapy-treated eye and 1 diode laser-treated eye progressed to stage 5 retinal detachment. CONCLUSION: Compared with cryotherapy, the diode laser was more convenient, technically easier to administer, and better tolerated by the patient. Although the number of patients was too small for meaningful statistical analysis of outcome, diode laser peripheral retinal ablation appeared to be as effective as cryotherapy for the treatment of threshold ROP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0161-6420(93)31664-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Hunter, D. G., & Repka, M. X.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
1993-02
Volume
100
Issue
2
Pages
238-244
ISSN
0161-6420 (ISSN-L)
OpenAlex
W97218921
Cited by
188
References
0
FWCI
7.57
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diode Laser Photocoagulation for Threshold Retinopathy of Prematurity. https://app.cochat.ai/papers/10.1016/s0161-6420(93)31664-7
The paper
Hunter, D. G., & Repka, M. X. (1993). Diode Laser Photocoagulation for Threshold Retinopathy of Prematurity. Ophthalmology. https://doi.org/10.1016/s0161-6420(93)31664-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.