The DOI matches its Crossref record.
Evaluation of Grid Pattern Photocoagulation for Macular Edema in Central Vein Occlusion
Open accessAbstract
PURPOSE: To evaluate the efficacy of macular grid photocoagulation in preserving or improving central visual acuity in eyes with macular edema due to central vein occlusion (CVO) and best-corrected visual acuity of 20/50 or poorer. METHODS: Patients with angiographically documented macular edema due to CVO were entered into a multicenter randomized controlled clinical trial supported by the National Eye Institute. Eligibility was determined based on both clinical examination findings and photographic documentation evaluated at a photograph reading center. Eyes were assigned randomly to macular grid photocoagulation (77 eyes) or no treatment (78 eyes). Patients were followed every 4 months for 3 years or until the end of the study. The outcome measure was visual acuity. RESULTS: The study population consisted of 155 eyes in 155 patients. There was no difference between treated and untreated eyes in visual acuity at any point during the follow-up period. Initial median visual acuity was 20/160 in treated eyes and 20/ 125 in control eyes. Final median visual acuity was 20/200 in treated eyes and 20/160 in control eyes. However, treatment clearly reduced angiographic evidence of macular edema. CONCLUSION: The results of this study do not support a recommendation for macular grid photocoagulation for the population meeting the Central Vein Occlusion Study macular edema group eligibility criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brown, D. M., Heier, J. S., Clark, W. L., Boyer, D. S., Vitti, R., Berliner, A. J., Zeitz, O., Sandbrink, R., Zhu, X., & Haller, J. A. (2013) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2012.09.026 · Cited by 365
Animal models of retinal vein occlusion
Khayat, M., Lois, N., Williams, M., & Stitt, A. W. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22788 · Cited by 42
Augustin, A. J., Sahel, J.-A., Cerulli, L., Texier-Richard, B., Buchholz, P. M., & Kobelt, G. (2012) · European Journal of Ophthalmology · doi:10.5301/ejo.5000180 · Cited by 7
Metadata
- Authors
- Clarkson, J. G., Chuang, E., Gass, D., Pedroso, M., Cubillas, T., Duria, E. S., Hess, D. J., Rams, I., Ball, M., Gutierrez, A., Muniz, N., Thompson, J., Pall, M., Pappas, C. J., Finkelstein, D., Patz, A., Rytel, D., Belt, J., Cain, D., Cain, T., Emmert, D., George, T., Herring, M., Sotirakos, P., Orth, D. H., Flood, T. P., Packo, K. H., Larsen, T., Perez, N., Bryant, D., Doherty, D., Fitzgerald, J., Gordon, M., Holod, C., Kwiatkowski, K., MacLeod, C., Morrison, C., Westcott, C., Klein, M. L., Wilson, D., Weleber, R. G., Nolte, S., Hurlburt, N., Evans, M., Wallace, P., Steinkamp, P., Funkner, D., Gordon, C., Trempe, C., Jalkh, A., Weiter, J., Anderson, S., Donovan, D., O'Day, T., Friedman, G., Immerman, R., Coscas, G., Soubrane, G., Haran, R. M., Debibie, C., Gizelsky, J., Wallow, I. H. L., de Venecia, G., Bresnick, G., Larson, S., Fuller, S., Harrison, B., Knutson, G., Neider, M., Weber, G., Bahr, R., Grosnick, B., Lazorik, R., Lyngaas, H., Quackenboss, D., Somers, G., Gutman, F. A., Myers, S., Kiss, T., Ross, D., Vargo, P., Edgarton, J., Hanson, S., Nader, J., Tomsak, N., Singerman, L. J., Zegarra, H., Lichterman, S., Fowler Kramer, A., Smith-Brewer, S., Brown Rowe, P., Daley, G., Pinter, A., Coreno, K., Cooper, L., Delisio, M., Cross, D., Lord, W., Hillis, A., Riggs, M. W., KasbergPreece, C., Rajab, M. H., Giniewicz, K. C., Gilmore, K., Zimmerman, C., Clarkson, J. G., Lewis, M. L., Chuang, E., Wells, M. C., Forbes, J. L., Fetzer, K. C., McNish, H., Bresnick, G. H., Fuller, S., McNulty, L., Baliker, J., Alanen, L., Gentry, L., Mowery, R. L., Everett, D. F., Clarkson, J. G., Bresnick, G. H., Coscas, G., Finkelstein, D., Gutman, F. A., Hillis, A., Klein, M. L., Mowery, R. L., Everett, D. F., Orth, D. H., Singerman, L. J., Trempe, C., Hardy, R. J., Abrams, G., Frank, R. N., Maguire, M. G., McCall, A. V., Clarkson, J. G., Everett, D. F., & Hillis, A.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1995-10
- Volume
- 102
- Issue
- 10
- Pages
- 1425-1433
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W1898187276
- Cited by
- 508
- References
- 0
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Grid Pattern Photocoagulation for Macular Edema in Central Vein Occlusion. https://app.cochat.ai/papers/10.1016/s0161-6420(95)30849-4
- The paper
- Clarkson, J. G., Chuang, E., Gass, D., Pedroso, M., Cubillas, T., Duria, E. S., Hess, D. J., Rams, I., Ball, M., Gutierrez, A., Muniz, N., Thompson, J., Pall, M., Pappas, C. J., Finkelstein, D., Patz, A., Rytel, D., Belt, J., Cain, D., . . . Hillis, A. (1995). Evaluation of Grid Pattern Photocoagulation for Macular Edema in Central Vein Occlusion. Ophthalmology. https://doi.org/10.1016/s0161-6420(95)30849-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.