Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record.

Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency

Open access
Liu, Zuguo, Pflugfelder, Stephen C · 1999 · Ophthalmology

Abstract

PURPOSE: To evaluate corneal surface regularity and the effect of artificial tears on the regularity of the corneal surface in dry eye. DESIGN: A prospective, clinic-based, case-control study. PARTICIPANTS: A total of 64 eyes of 33 normal subjects and 42 eyes of 22 patients with aqueous tear deficiency were evaluated. METHODS: Indices of the TMS-1 corneal topography instrument (Tomey Technology, Cambridge, MA) were used to evaluate corneal surface regularity and potential visual acuity (PVA) in patients with aqueous tear deficiency dry eye before and after the instillation of artificial tears and in normal subjects. The TMS-1 topographic maps were classified into round, oval, symmetric bow-tie, asymmetric bow-tie, and irregular patterns. MAIN OUTCOME MEASURES: The surface regularity index (SRI), surface asymmetry index (SAI), PVA index, and topographic pattern of the TMS-1 were compared between normal and dry eyes and in dry eyes before and after the instillation of artificial tears. RESULTS: The SRI and SAI were significantly elevated and the PVA was significantly reduced in dry eye patients compared with normal subjects: 0.31+/-0.22, 0.30+/-0.16, and 20/17.89+/-20/3.04, respectively, in normal subjects and 1.28+/-0.73, 1.05+/-1.17, and 20/33.45+/-20/13.99, respectively, in patients with dry eye (P<0.001 for all indices). The average amount of astigmatism was also increased in dry eyes (2.10+/-1.96 prism diopters) compared with normal eyes (1.13+/-0.53 prism diopters, P = 0.02). In dry eyes, the SRI and SAI were positively correlated with corneal fluorescein staining scores (P = 0.005 for SRI and P = 0.016 for SAI). The mean PVA was not significantly different from the mean actual corrected visual acuity. The dry eyes had a significantly lower percentage of symmetric bow-tie patterns and a greater percentage of irregular patterns on topographic maps than normal eyes. After the instillation of artificial tears, the SRI, SAI, and mean astigmatism all decreased significantly (P<0.001 for SRI, P<0.002 for SAI, P = 0.04 for astigmatism) and the PVA improved (P<0.001) in dry eyes. An irregular topographic pattern was observed in 45.24% of dry eyes, and this decreased to 30.95% after the instillation of artificial tears (P<0.005). CONCLUSIONS: Patients with aqueous deficiency have an irregular corneal surface that may contribute to their visual difficulties. The SRI and SAI could be used as objective diagnostic indices for dry eye as well as for evaluating the severity of this disease and the effect of artificial tears. Artificial tears have the secondary benefit of smoothing the corneal surface in dry eye.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0161-6420(99)00513-8

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
Liu, Z., & Pflugfelder, S. C.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
1999-05
Volume
106
Issue
5
Pages
939-943
ISSN
0161-6420 (ISSN-L)
OpenAlex
W1490720169
Cited by
205
References
0
FWCI
4.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency. https://app.cochat.ai/papers/10.1016/s0161-6420(99)00513-8
The paper
Liu, Z., & Pflugfelder, S. C. (1999). Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency. Ophthalmology. https://doi.org/10.1016/s0161-6420(99)00513-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.