The cryoloop: an adaptable reversible cooling deactivation method for behavioral or electrophysiological assessment of neural function
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We describe a very adaptable reversible inactivation technique for the behavioral or electrophysiological analysis of neural circuits. The cryoloop device can be permanently implanted or topically applied in an acute preparation to apply cold to discrete surface regions of the central nervous system (e.g. cerebral cortex or midbrain). The cryoloop consists of a custom shaped, stainless steel, hypodermic tubing and cooling is effected by passing chilled methanol through the lumen of the tubing. Cryoloop temperature is monitored by a microthermocouple attached to the union of the loop, and can be maintained within +/- 1 degrees C of a desired temperature. In chronic preparations, implanted cryoloops have been maintained in cats and monkeys for periods in excess of 2 years. After this period there are no structural, metabolic of functional changes in the deactivated tissue, and full reversibility of cooling-induced effects is maintained. Operation of multiple cryoprobes provides great flexibility of experimental protocols, permits double and triple functional dissociations to be made, and strengthens experimental design considerably.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical feedback improves discrimination between figure and background by V1, V2 and V3 neurons
Hupé, J. M., James, A. C., Payne, B. R., Lomber, S. G., Girard, P., & Bullier, J. (1998) · Nature · doi:10.1038/29537 · Cited by 864 · cited 5×
“Keywords: Cerebral cortex; Superior colliculus; Perception; Cognition; Modeling”
BackgroundMethodInfluentialSelf-citationEffects of local cooling upon conduction and synaptic transmission
Bénita, M., & Condé, H. (1972) · Brain Research · doi:10.1016/0006-8993(72)90771-8 · Cited by 311 · cited 1×
“These values conform with previous measurements of Jasper et al. (1970) and Benita and Conde (1972).”
ResultBjörklund, A., & Nobin, A. (1973) · Brain Research · doi:10.1016/0006-8993(73)90372-7 · Cited by 298
Retinotopic organization of areas 20 and 21 in the cat
Tusa, R. J., & Palmer, L. A. (1980) · The Journal of Comparative Neurology · doi:10.1002/cne.901930110 · Cited by 284 · cited 3×
“…over the dorsal-posterior suprasylvian gyrus and PS-MS junction (cortical area 21a; Tusa and Palmer, 1980). vPSg) Cryoloop placed over the ventral-posterior suprasylvian gyrus which wraps around onto the tentorial surface over the fusiform gyrus (cortical area 20a and 20b; Tusa and Palmer, 1980).”
BackgroundInfluentialGirard, P., Salin, P. A., & Bullier, J. (1992) · Journal of Neurophysiology · doi:10.1152/jn.1992.67.6.1437 · Cited by 216
The performance of visual tasks while segments of the inferotemporal cortex are suppressed by cold
Horel, J. A., Pytko-Joiner, D. E., Voytko, M. L., & Salsbury, K. (1987) · Behavioural Brain Research · doi:10.1016/0166-4328(87)90240-3 · Cited by 209 · cited 1×
“…to assess cortical operations using, with equal success, behavioral or electrophysiological assays of neural operations (Horel, 1984, 1992, 1996; Horel et al. 1984, 1987; Payne et al., 1991, 1996a; Lomber et al., 1994, 1996a,b; Lomber and Payne, 1996; Girard et al. 1997; Hupé et al., 1998).”
MethodSelf-citationEffect of cooling area 18 on striate cortex cells in the squirrel monkey.
Sandell, J. H., & Schiller, P. H. (1982) · Journal of Neurophysiology · doi:10.1152/jn.1982.48.1.38 · Cited by 189 · cited 2×
“Keywords: Cerebral cortex; Superior colliculus; Perception; Cognition; Modeling”
MethodVisual activity in area V2 during reversible inactivation of area 17 in the macaque monkey
Girard, P., & Bullier, J. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.62.6.1287 · Cited by 179 · cited 1×
“…used in electrophysiological investigations, where the cooling of large, relatively smooth, cortical areas has been successfully carried out (Schiller and Malpeli, 1977; Sherk, 1978; Sandell and Schiller, 1982; Girard and Bullier, 1989; Girard et al., 1991a,b, 1992; Michalski et al., 1993, 1994).”
MethodMotion Perception following Lesions of the Superior Temporal Sulcus in the Monkey
Pasternak, T., & Merigan, W. H. (1994) · Cerebral Cortex · doi:10.1093/cercor/4.3.247 · Cited by 161 · cited 2×
“These compensations mask the original lesion-induced deficits (see Payne et al. (1996b) for examples and discussion).”
BackgroundAlexander, G. E., & Goldman, P. S. (1978) · Brain Research · doi:10.1016/0006-8993(78)90566-8 · Cited by 129 · cited 1×
“In behavioral studies the plates are positioned outside the dura, a structure which tends to insulate the underlying brain from the cooling effect (Fuster and Alexander, 1970; Fuster and Bauer, 1974; Goldman and Alexander, 1977; Alexander and Goldman, 1978; Shindy et al., 1994).”
The effect of striate cortex cooling on area 18 cells in the monkey
Schiller, P. H., & Malpeli, J. G. (1977) · Brain Research · doi:10.1016/0006-8993(77)90734-x · Cited by 127 · cited 1×
“…been used in electrophysiological investigations, where the cooling of large, relatively smooth, cortical areas has been successfully carried out (Schiller and Malpeli, 1977; Sherk, 1978; Sandell and Schiller, 1982; Girard and Bullier, 1989; Girard et al., 1991a,b, 1992; Michalski et al., 1993,…”
Visual activity in areas V3a and V3 during reversible inactivation of area V1 in the macaque monkey
Girard, P., Salin, P. A., & Bullier, J. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.66.5.1493 · Cited by 126 · cited 1×
“…used in electrophysiological investigations, where the cooling of large, relatively smooth, cortical areas has been successfully carried out (Schiller and Malpeli, 1977; Sherk, 1978; Sandell and Schiller, 1982; Girard and Bullier, 1989; Girard et al., 1991a,b, 1992; Michalski et al., 1993, 1994).”
MethodLomber, S. G., & Payne, B. R. (1996) · Visual Neuroscience · doi:10.1017/s0952523800007781 · Cited by 121 · cited 9×
“However, the major factor limiting the number of cryoprobes that can be implanted is the duration of the surgery.”
BackgroundMethodInfluentialSelf-citationDelayed response deficit by cryogenic depression of frontal cortex
Fuster, J. M., & Alexander, G. E. (1970) · Brain Research · doi:10.1016/0006-8993(70)90156-3 · Cited by 121 · cited 1×
“In behavioral studies the plates are positioned outside the dura, a structure which tends to insulate the underlying brain from the cooling effect (Fuster and Alexander, 1970; Fuster and Bauer, 1974; Goldman and Alexander, 1977; Alexander and Goldman, 1978; Shindy et al., 1994).”
BackgroundArea 18 cell responses in cat during reversible inactivation of area 17
Sherk, H. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.1.204 · Cited by 104 · cited 2×
“These have been used in electrophysiological investigations, where the cooling of large, relatively smooth, cortical areas has been successfully carried out (Schiller and Malpeli, 1977; Sherk, 1978; Sandell and Schiller, 1982; Girard and Bullier, 1989; Girard et al., 1991a,b, 1992; Michalski et al., 1993, 1994).”
MethodVisual learning suppressed by cooling the temporal pole.
Horel, J. A., Voytko, M. L., & Salsbury, K. G. (1984) · Behavioral Neuroscience · doi:10.1037//0735-7044.98.2.310 · Cited by 100 · cited 1×
“…to assess cortical operations using, with equal success, behavioral or electrophysiological assays of neural operations (Horel, 1984, 1992, 1996; Horel et al. 1984, 1987; Payne et al., 1991, 1996a; Lomber et al., 1994, 1996a,b; Lomber and Payne, 1996; Girard et al. 1997; Hupé et al., 1998).”
MethodSelf-citationRecovery of function after lesions in the superior temporal sulcus in the monkey
Yamasaki, D. S. G., & Wurtz, R. H. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.66.3.651 · Cited by 96 · cited 2×
“After this period there are no structural, metabolic of functional changes in the deactivated tissue, and full reversibility of cooling-induced effects is maintained.”
BackgroundReversible visual hemineglect.
Payne, B. R., Lomber, S. G., Geeraerts, S., van der Gucht, E., & Vandenbussche, E. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.1.290 · Cited by 93 · cited 11×
“2B; Lomber and Payne, 1996; Payne et al., 1996a).”
BackgroundMethodInfluentialSelf-citationVisual short-term memory deficit from hypothermia of frontal cortex
Fuster, J. M., & Bauer, R. H. (1974) · Brain Research · doi:10.1016/0006-8993(74)90838-5 · Cited by 93 · cited 1×
“In behavioral studies the plates are positioned outside the dura, a structure which tends to insulate the underlying brain from the cooling effect (Fuster and Alexander, 1970; Fuster and Bauer, 1974; Goldman and Alexander, 1977; Alexander and Goldman, 1978; Shindy et al., 1994).”
BackgroundReversible deactivation of cerebral network components
Payne, B. R., Lomber, S. G., Villa, A. E., & Bullier, J. (1996) · Trends in Neurosciences · doi:10.1016/s0166-2236(96)10061-8 · Cited by 91 · cited 10×
“2B; Lomber and Payne, 1996; Payne et al., 1996a).”
BackgroundMethodInfluentialSelf-citationPerceptual and Cognitive Visual Functions of Parietal and Temporal Cortices in the Cat
Lomber, S. G., Payne, B. R., Cornwell, P., & Long, K. D. (1996) · Cerebral Cortex · doi:10.1093/cercor/6.5.673 · Cited by 88 · cited 9×
“(1) Electrophysiology: Routine electrophysiological methods (Payne, 1990) are used to verify cooling deactivation of neuronal activity and determine directly the laminar and spatial extent of the cortical area deactivated (e.g. Lomber et al., 1994, 1996b; Payne et al., 1996b).”
BackgroundMethodInfluentialSelf-citationFunctional impact of cerebral connections
Vanduffel, W., Payne, B. R., Lomber, S. G., & Orban, G. A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.14.7617 · Cited by 85 · cited 2×
“In addition to defining the local, cooling impact zone, the cooling modulates 2DG uptake at distant sites in receipt of efferent projections from the cooled cortex (Vanduffel et al., 1997).”
BackgroundSelf-citationPayne, B. R. (1990) · Visual Neuroscience · doi:10.1017/s0952523800005204 · Cited by 83 · cited 1×
“(1) Electrophysiology: Routine electrophysiological methods (Payne, 1990) are used to verify cooling deactivation of neuronal activity and determine directly the laminar and spatial extent of the cortical area deactivated (e.g. Lomber et al., 1994, 1996b; Payne et al., 1996b).”
MethodSelf-citationMalpeli, J. G. (1983) · Journal of Neurophysiology · doi:10.1152/jn.1983.49.3.595 · Cited by 82 · cited 1×
“…deactivation are obtained using Brainwave Systems’ ‘Discovery’ software to collect multiple channels of extracellular spike activity (e.g. Lomber et al., 1994, 1996a; Mendola and Payne, 1993; Payne et al., 1991, 1996b), and calculation of a cooling block: normal ratio (B:N ratio, Malpeli, 1983).”
MethodMaturation of prefrontal cortex in the monkey revealed by local reversible cryogenic depression
Goldman, P. S., & Alexander, G. E. (1977) · Nature · doi:10.1038/267613a0 · Cited by 80 · cited 1×
“In behavioral studies the plates are positioned outside the dura, a structure which tends to insulate the underlying brain from the cooling effect (Fuster and Alexander, 1970; Fuster and Bauer, 1974; Goldman and Alexander, 1977; Alexander and Goldman, 1978; Shindy et al., 1994).”
BackgroundSokoloff, L. (1981) · Profiles in Science · Cited by 80
The effect of local cooling upon spontaneous and evoked electrical activity of cerebral cortex
Jasper, H. H., Shacter, D. G., & Montplaisir, J. Y. (1970) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y70-094 · Cited by 78 · cited 1×
“These values conform with previous measurements of Jasper et al. (1970) and Benita and Conde (1972).”
ResultCortical and subcortical afferent connections of a posterior division of feline area 7 (Area 7p)
Olson, C. R., & Lawler, K. (1987) · The Journal of Comparative Neurology · doi:10.1002/cne.902590103 · Cited by 74 · cited 2×
“MSg) Cryoloop implanted over the middle suprasylvian gyrus (cortical area 7; Olson and Lawler, 1987).”
BackgroundLomber, S. G., Cornwell, P., Sun, J. S., MacNeil, M. A., & Payne, B. R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.8.2999 · Cited by 71 · cited 7×
“(1) Electrophysiology: Routine electrophysiological methods (Payne, 1990) are used to verify cooling deactivation of neuronal activity and determine directly the laminar and spatial extent of the cortical area deactivated (e.g. Lomber et al., 1994, 1996b; Payne et al., 1996b).”
BackgroundMethodInfluentialSelf-citationComplex transcallosal interactions in visual cortex
Payne, B. R., Siwek, D. F., & Lomber, S. G. (1991) · Visual Neuroscience · doi:10.1017/s0952523800006283 · Cited by 70 · cited 2×
“…to assess cortical operations using, with equal success, behavioral or electrophysiological assays of neural operations (Horel, 1984, 1992, 1996; Horel et al. 1984, 1987; Payne et al., 1991, 1996a; Lomber et al., 1994, 1996a,b; Lomber and Payne, 1996; Girard et al. 1997; Hupé et al., 1998).”
MethodSelf-citationSokoloff, L. (1981) · International review of neurobiology · doi:10.1016/s0074-7742(08)60296-2 · Cited by 70
Visual activity in macaque area V4 depends on area 17 input
Girard, P., Salin, P.-A., & Bullier, J. (1991) · NeuroReport · doi:10.1097/00001756-199102000-00004 · Cited by 57 · cited 1×
“…used in electrophysiological investigations, where the cooling of large, relatively smooth, cortical areas has been successfully carried out (Schiller and Malpeli, 1977; Sherk, 1978; Sandell and Schiller, 1982; Girard and Bullier, 1989; Girard et al., 1991a,b, 1992; Michalski et al., 1993, 1994).”
MethodMichalski, A., Wimborne, B., & Henry, G. H. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019713 · Cited by 55 · cited 2×
“Keywords: Cerebral cortex; Superior colliculus; Perception; Cognition; Modeling”
MethodKeating, E. G., & Gooley, S. G. (1988) · Brain Research · doi:10.1016/0006-8993(88)91343-1 · Cited by 55 · cited 1×
“…been used successfully to deactivate surface regions (Horel, 1984, 1992, 1996; Lomber et al., 1996a,b), cortex buried within sulci (Lomber et al., 1994, 1996b, Payne et al., 1996a; Hupé et al., 1998), and superior colliculus (Keating and Gooley, 1988; Lomber and Payne, 1996; Payne et al., 1996a).”
MethodLomber, S. G., Payne, B. R., & Cornwell, P. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.4.1654 · Cited by 52 · cited 9×
“(1) Electrophysiology: Routine electrophysiological methods (Payne, 1990) are used to verify cooling deactivation of neuronal activity and determine directly the laminar and spatial extent of the cortical area deactivated (e.g. Lomber et al., 1994, 1996b; Payne et al., 1996b).”
BackgroundMethodInfluentialSelf-citationReversible Deficit in Haptic Delay Tasks from Cooling Prefrontal Cortex
Shindy, W. W., Posley, K. A., & Fuster, J. M. (1994) · Cerebral Cortex · doi:10.1093/cercor/4.4.443 · Cited by 46 · cited 2×
“Keywords: Cerebral cortex; Superior colliculus; Perception; Cognition; Modeling”
BackgroundA method to assess the functional impact of cerebral connections on target populations of neurons
Payne, B. R., & Lomber, S. G. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00166-6 · Cited by 43 · cited 4×
“Terminal checks At the end of behavioral testing, we recommend assigning animals to subgroups to verify cooling induced deactivation using electrophysiological methods or map the deactivated region of cortex with microthermocouples or 2-deoxy-14C-glucose (2DG; Payne and Lomber, 1999).”
BackgroundMethodInfluentialSelf-citationHorel, J. A. (1984) · Physiological Psychology · doi:10.3758/bf03327197 · Cited by 41 · cited 2×
“…method can be applied to assess cortical operations using, with equal success, behavioral or electrophysiological assays of neural operations (Horel, 1984, 1992, 1996; Horel et al. 1984, 1987; Payne et al., 1991, 1996a; Lomber et al., 1994, 1996a,b; Lomber and Payne, 1996; Girard et al.…”
MethodSelf-citationLesion-induced network plasticity in remote brain areas.
Witte, O. W., Buchkremer-Ratzmann, I., Schiene, K., Neumann‐Haefelin, T., Hagemann, G., Kraemer, M., Zilles, K., & Hj, F. (1997) · PubMed · Cited by 38
Horel, J. A. (1996) · Behavioural Brain Research · doi:10.1016/0166-4328(95)00196-4 · Cited by 22 · cited 2×
“…method can be applied to assess cortical operations using, with equal success, behavioral or electrophysiological assays of neural operations (Horel, 1984, 1992, 1996; Horel et al. 1984, 1987; Payne et al., 1991, 1996a; Lomber et al., 1994, 1996a,b; Lomber and Payne, 1996; Girard et al.…”
MethodSelf-citationMichalski, A., Wimborne, B., & Henry, G. H. (1994) · Visual Neuroscience · doi:10.1017/s0952523800003801 · Cited by 12 · cited 1×
“…used in electrophysiological investigations, where the cooling of large, relatively smooth, cortical areas has been successfully carried out (Schiller and Malpeli, 1977; Sherk, 1978; Sandell and Schiller, 1982; Girard and Bullier, 1989; Girard et al., 1991a,b, 1992; Michalski et al., 1993, 1994).”
MethodHorel, J. A. (1992) · Behavioural Brain Research · doi:10.1016/s0166-4328(05)80213-x · Cited by 11 · cited 2×
“…method can be applied to assess cortical operations using, with equal success, behavioral or electrophysiological assays of neural operations (Horel, 1984, 1992, 1996; Horel et al. 1984, 1987; Payne et al., 1991, 1996a; Lomber et al., 1994, 1996a,b; Lomber and Payne, 1996; Girard et al.…”
MethodSelf-citation
Cited by
Studying and modifying brain function with non-invasive brain stimulation
Polanía, R., Nitsche, M. A., & Ruff, C. C. (2018) · Nature Neuroscience · doi:10.1038/s41593-017-0054-4 · Cited by 1,028
Cross-modal plasticity in specific auditory cortices underlies visual compensations in the deaf
Lomber, S. G., Meredith, M. A., & Kral, A. (2010) · Nature Neuroscience · doi:10.1038/nn.2653 · Cited by 520
Self-citationBrain temperature and its fundamental properties: a review for clinical neuroscientists
Wang, H., Wang, B., Normoyle, K. P., Jackson, K., Spitler, K., Sharrock, M. F., Miller, C. M., Best, C., Llano, D., & Du, R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00307 · Cited by 356
“…demonstrated that repeated cooling did not alter neuronal responsiveness, animal behavior, or produce anatomical damage (Keating and Gooley, 1988; Lomber et al., 1996, 1999; Fingas et al., 2007), very little is known about human cerebral tissue’s response and tolerance to chronic exposure to a…”
BackgroundFeedback Connections Act on the Early Part of the Responses in Monkey Visual Cortex
Hupé, J.-M., James, A. C., Girard, P., Lomber, S. G., Payne, B. R., & Bullier, J. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.1.134 · Cited by 318
Self-citationDouble dissociation of 'what' and 'where' processing in auditory cortex
Lomber, S. G., & Malhotra, S. (2008) · Nature Neuroscience · doi:10.1038/nn.2108 · Cited by 295
Self-citation
Metadata
- Authors
- Lomber, S. G., Payne, B. R., & Horel, J. A.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 86
- Issue
- 2
- Pages
- 179-194
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2100232001
- Cited by
- 232
- References
- 43
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.