An adaptive fuzzy C-means algorithm for image segmentation in the presence of intensity inhomogeneities
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
We present a novel algorithm for obtaining fuzzy segmentations of images that are subject to multiplicative intensity inhomogeneities, such as magnetic resonance images. The algorithm is formulated by modifying the objective function in the fuzzy C-means algorithm to include a multiplier field, which allows the centroids for each class to vary across the image. First and second order regularization terms ensure that the multiplier field is both slowly varying and smooth. An iterative algorithm that minimizes the objective function is described, and its efficacy is demonstrated on several test images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density Estimation for Statistics and Data Analysis
Silverman, B. W. (2018) · Routledge eBooks · doi:10.1201/9781315140919 · Cited by 15,796
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
Briggs, W. L. (1987) · Cited by 1,868
Unsupervised optimal fuzzy clustering
Gath, I., & Geva, A. B. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192473 · Cited by 1,640
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
A Convergence Theorem for the Fuzzy ISODATA Clustering Algorithms
Bezdek, J. C. (1980) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1980.4766964 · Cited by 980
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
Udupa, J. K., & Samarasekera, S. (1996) · Graphical Models and Image Processing · doi:10.1006/gmip.1996.0021 · Cited by 839
Statistical approach to segmentation of single-channel cerebral MR images
Rajapakse, J. C., Giedd, J. N., & Rapoport, J. L. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563663 · Cited by 678
An adaptive clustering algorithm for image segmentation
Pappas, T. N. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.127962 · Cited by 589
Susceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Correction of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291
Sources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Retrospective correction of intensity inhomogeneities in MRI
Meyer, C. R., Bland, P. H., & Pipe, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370400 · Cited by 176
Brandt, M. E., Bohant, T. P., Kramer, L. A., & Fletcher, J. M. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90058-2 · Cited by 139
Allison, J. D., Flickinger, F. W., Wright, J. C., Falls, D. G., Prisant, L. M., VonDohlen, T. W., & Frank, M. J. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90065-l · Cited by 76
High-Resolution Anatomy from in Situ Human Brain
Toga, A. W., Ambach, K. L., & Schluender, S. J. (1994) · NeuroImage · doi:10.1006/nimg.1994.1018 · Cited by 49
Cited by
Current Methods in Medical Image Segmentation
Pham, D. L., Xu, C., & Prince, J. L. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.315 · Cited by 2,341
Self-citationChen, S., & Zhang, D. (2004) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2004.831165 · Cited by 1,142
A Robust Fuzzy Local Information C-Means Clustering Algorithm
Krinidis, S., & Chatzis, V. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2040763 · Cited by 1,124
Cai, W., Chen, S., & Zhang, D. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2006.07.011 · Cited by 1,088
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Metadata
- Authors
- Pham, D. L., & Prince, J. L.
- Venue
- Pattern Recognition Letters
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 20
- Issue
- 1
- Pages
- 57-68
- ISSN
- 0167-8655 (ISSN-L)
- OpenAlex
- W2038533573
- Cited by
- 472
- References
- 18
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.