Endocytosis of soluble IgG immune complex and its transport to lysosomes in hepatic sinusoidal endothelial cells
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Both Kupffer cells and sinusoidal endothelial cells are engaged in the hepatic uptake of soluble IgG immune complex (IgG-IC) through Fc-receptors on their surface. Hepatocytes have also been reported to take up IgG-IC. It remains unclear, however, whether the endothelial cell degrades IgG-IC and whether the hepatocyte participates in IgG-IC clearance. In this study, normal mice received a single intravenous injection of soluble immune complex preformed in antigen excess, i.e. bovine serum albumin (BSA) anti-BSA-mouse-IgG complex (BABIgG) or BSA anti-BSA-mouse-F(ab')2 complex (BABF(ab')2), or BSA alone. An immunoperoxidase study for BSA showed that from 1 to 120 min after injection only BABIgG was ingested by both endothelial cells and Kupffer cells but not by hepatocytes. The staining intensity of BABIgG was maximal at about 15 min and decreased subsequently. Endocytosis of BABIgG occurred through coated pits in the endothelial cells. Within a few minutes, endocytosed BABIgG was found in tubulovesicular structures and large vesicles. The occasional large vesicles were shown to be lysosomes by simultaneous demonstration of BABIgG with acid phosphatase. BABIgG was not found on either of the endothelial and hepatocellular surfaces facing the space of Disse or in hepatocytes. These results indicate that soluble IgG-IC is endocytosed by sinusoidal endothelial cells and degraded in the lysosomes and that the participation of hepatocytes in the clearance of IgG-IC is improbable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mannose 6-phosphate receptor and the biogenesis of lysosomes
Griffiths, G., Hoflack, B., Simons, K., Mellman, I., & Kornfeld, S. (1988) · Cell · doi:10.1016/s0092-8674(88)80026-6 · Cited by 855
Cited by
Immune surveillance by the liver
Jenne, C. N., & Kubes, P. (2013) · Nature Immunology · doi:10.1038/ni.2691 · Cited by 1,047
Kubes, P., & Jenne, C. (2018) · Annual Review of Immunology · doi:10.1146/annurev-immunol-051116-052415 · Cited by 923
The influence of protein adsorption on nanoparticle association with cultured endothelial cells
Ehrenberg, M. S., Friedman, A. E., Finkelstein, J. N., Oberdörster, G., & McGrath, J. L. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.050 · Cited by 412
“As immunoglobulins are known to be taken into endothelial cells by clathrin mediated endocytosis [38], this pathway likely plays a role in the complete HS results.”
BackgroundPharmacokinetics and toxicology of therapeutic proteins: Advances and challenges
Vugmeyster, Y. (2012) · World Journal of Biological Chemistry · doi:10.4331/wjbc.v3.i4.73 · Cited by 242
Viñas, O., Bataller, R., Sancho-Bru, P., Ginès, P., Berenguer, C., Enrich, C., Nicolás, J. M., Ercilla, G., Gallart, T., Vives, J., et al. (2003) · Hepatology · doi:10.1002/hep.1840380418 · Cited by 223
FcγRIIb on Liver Sinusoidal Endothelium Clears Small Immune Complexes
Ganesan, L. P., Kim, J., Wu, Y., Mohanty, S., Phillips, G. S., Birmingham, D. J., Robinson, J. M., & Anderson, C. L. (2012) · The Journal of Immunology · doi:10.4049/jimmunol.1202017 · Cited by 166
“Further, the literature supports this conclusion with abundant direct data showing liver clearance of the major fraction of blood-borne SIC (1, 3, 4, 15, 39, 40).”
Metadata
- Authors
- Kosugi, I., Muro, H., Shirasawa, H., & Ito, I.
- Venue
- Journal of Hepatology
- Publisher
- Elsevier BV
- Published
- 1992-01
- Volume
- 16
- Issue
- 1-2
- Pages
- 106-114
- ISSN
- 0168-8278 (ISSN-L)
- OpenAlex
- W1972624827
- Cited by
- 56
- References
- 1
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.