Cited by 93Radiopharmaceutical Chemistry and ApplicationsNanoparticle-Based Drug DeliveryMedical Imaging Techniques and Applications

Liposomes for scintigraphic detection of infection and inflammation

Laverman, P·1999·Advanced Drug Delivery Reviews

Abstract

Liposomes are small vesicles consisting of one or more concentric lipid bilayers enclosing discrete aqueous spaces. Liposomes potentially serve as carriers for radiolabels to visualize pathological processes scintigraphically. Research performed during the last two decades has revealed insight on the characteristics of liposomes with regard to their tissue distribution after i.v. injection. Various approaches have been developed to radiolabel liposomes with gamma-emitting radionuclides such as Ga-67, In-111 and Tc-99m. Preferably, liposomes are labeled according to the 'after-loading' method. The radionuclide can either be encapsulated in the aqueous interior or coupled to the lipid bilayer. The potential of radiolabeled liposomes to image infectious and inflammatory foci has been demonstrated in a variety of preclinical studies. Recently, a study in patients suspected of having infectious or inflammatory disease has been initiated. Preliminary clinically results exemplify the potential of Tc-99m-PEG liposomes to image infection and inflammation.

Integrity signals

Registry

Crossref · 10.1016/s0169-409x(98)00095-7

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • There have been several studies that show higher accumulation of nanocarriers at sites of infection compared with non-infected sites.

    “There have also been several studies that show higher accumulation of nanocarriers at sites of infection compared with non-infected sites (reviewed in ref. 47 ).”

    From Nanotechnology approaches for global infectious diseases (2021) · cites this paper as [47]

The citation lists haven’t been fetched yet

References 59 · Cited by 93

Authors
Laverman, P.
Affiliations
Radboud University Nijmegen (NL)
Corresponding author
Laverman, P
Venue
Advanced Drug Delivery Reviews
Publisher
Elsevier BV
Published
1999-04-05
Volume
37
Issue
1-3
Pages
225-235
ISSN
0169-409X (ISSN-L)
OpenAlex
W2127700889
Cited by
93
References
59
Citations by year
2026: 4 · 2025: 2 · 2024: 5 · 2023: 3 · 2022: 4 · 2021: 2 · 2020: 7 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 5 · 2015: 2 · 2014: 1 · 2013: 7 · 2012: 4
FWCI
3.16
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Drug Delivery Reviews (publishedVersion)
  • PubMed (publishedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
  • Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
Keywords
liposomes, scintigraphy, infection imaging, inflammation imaging, radiolabeling, gallium-67, indium-111, technetium-99m, PEGylated liposomes, tissue distribution, gamma-emitting radionuclides

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review