Optimal transducer placement for health monitoring of long span bridge
The DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The contribution to kinetic energy at each location indicates the sensor's ability to retain structural dynamic information even where sensor noise is present [135].”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [135]
In the citing paper
“In [135], the authors state that the greater the system's kinetic energy, the greater the signal-to-noise ratio.”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [135]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Los Alamos National Lab., N. (. S., Doebling, S., USDOE, W., Farrar, C., Prime, M., & Shevitz, D. (1996) · doi:10.2172/249299 · Cited by 2,899
Modal Testing: Theory and Practice
Ewins, D. J., & Saunders, H. (1986) · Journal of Vibration and Acoustics · doi:10.1115/1.3269294 · Cited by 2,507
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Modal testing: Theory and practice
Penny, J. (1988) · Journal of Mechanical Working Technology · doi:10.1016/0378-3804(88)90154-4 · Cited by 517
Optimal Weighted Orttiogonalization of Measured Modes
Baruch, M., & Bar Itzhack, I. Y. (1978) · AIAA Journal · doi:10.2514/3.60896 · Cited by 408
Methodology for Optimum Sensor Locations for Parameter Identification in Dynamic Systems
Udwadia, F. E. (1994) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1994)120:2(368 · Cited by 278
Method for optimal actuator and sensor placement for large flexible structures
Lim, K. B. (1992) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20800 · Cited by 173
A Bayesian Approach to Optimal Sensor Placement
Cameron, A., & Durrant-Whyte, H. F. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900505 · Cited by 116
Kammer, D. C. (1992) · Journal of Guidance Control and Dynamics · doi:10.2514/3.20841 · Cited by 96
Udwadia, F. E., Sharma, D. K., & Shah, P. C. (1978) · Journal of Applied Mechanics · doi:10.1115/1.3424224 · Cited by 76
Two-dimensional optimal sensor placement
Zhang, H. (1995) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/21.376491 · Cited by 68
Optimal weighted orthogonalization of measured modes
Berman, A. (1979) · AIAA Journal · doi:10.2514/3.7529 · Cited by 57
Optimum placement of controls for static deformations of space structures
Haftka, R. T. (1984) · AIAA Journal · doi:10.2514/3.8775 · Cited by 46
Optimal Sensor Locations for Structural Identification
Udwadia, F. E., & GARBA, J. (1985) · NASA STI Repository (National Aeronautics and Space Administration) · Cited by 41
A health monitoring system for large structural systems
Wang, M. L., Heo, G., & Satpathi, D. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/5/005 · Cited by 35
Self-citationDiffraction of a Shock Wave by a Compression Corner: Part II - Single Mach Reflection
Shankar, V., Kutler, P., & Anderson, D. (1978) · AIAA Journal · doi:10.2514/3.60850 · Cited by 33
Formulations and applications of large structure actuator and sensor placements
Juang, J.-N., & Rodríguez, G. (1979) · NASA Technical Reports Server (NASA) · Cited by 33
Optimal actuator placement in adaptive precision trusses
BAYCAN, C., Utku, S., Das, S., & Wada, B. K. (1992) · AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference (SDM) · doi:10.2514/6.1992-2344 · Cited by 9
Optimal sensor placement in decentralized control systems
Oloomi, H. M., & Sawan, M. E. (1989) · International Journal of Systems Science · doi:10.1080/00207728908910182 · Cited by 6
NONDESTRUCTIVE EVALUATION OF HIGHWAY BRIDGES BY DYNAMIC MONITORING
Alampalli, S., Fu, G., & Aziz, I. A. B. A. (1992) · Cited by 6
Sensor placement in structural control
Baruh, H., & Choe, K. (1988) · Guidance, Navigation and Control Conference · doi:10.2514/6.1988-4056 · Cited by 5
Cited by
On the optimal sensor placement techniques for a bridge structure
Meo, M., & Zumpano, G. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2005.03.015 · Cited by 389
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
The connection between effective independence and modal kinetic energy methods for sensor placement
Li, D. S., Li, H. N., & Fritzen, C. P. (2007) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2007.05.004 · Cited by 184
“(6) and (7), it can be certainly observed that the result of the first iteration of EI should be the same as that of the MKE, which is already shown clearly in the examples of references using EI methods [2,3,15–18].”
MethodResultHassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Robustness of optimal sensor placement under parametric uncertainty
Castro‐Triguero, R., Murugan, S., Gallego, R., & Friswell, M. I. (2013) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2013.06.022 · Cited by 121
Metadata
- Authors
- Heo, G., Wang, M. L., & Satpathi, D.
- Venue
- Soil Dynamics and Earthquake Engineering
- Publisher
- Elsevier BV
- Published
- 1997-01
- Volume
- 16
- Issue
- 7-8
- Pages
- 495-502
- ISSN
- 0267-7261 (ISSN-L)
- OpenAlex
- W2021274998
- Cited by
- 163
- References
- 22
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.