High-pass filtering to remove electrocardiographic interference from torso EMG recordings
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Spectral analysis of human inspiratory diaphragmatic electromyograms
Schweitzer, T. W., Fitzgerald, J. W., Bowden, J. A., & Lynne-Davies, P. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.46.1.152 · Cited by 148
Schoening, H. A. (1986) · Archives of Physical Medicine and Rehabilitation · doi:10.5555/uri:pii:0003999386903758 · Cited by 76
Filtering by adaptive sampling (FAS)
Aminian, K., Ruffieux, C., & Robert, P. A. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447507 · Cited by 25
Cited by
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Drake, J. D. M., & Callaghan, J. P. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.07.003 · Cited by 399
Methodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
Removing ECG noise from surface EMG signals using adaptive filtering
Lu, G., Brittain, J.-S., Holland, P., Yianni, J., Green, A. L., Stein, J. F., Aziz, T. Z., & Wang, S. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.063 · Cited by 222
Stress detection using ECG and EMG signals: A comprehensive study
Pourmohammadi, S., & Maleki, A. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105482 · Cited by 213
Reducing Noise, Artifacts and Interference in Single-Channel EMG Signals: A Review
Boyer, M., Bouyer, L., Roy, J.-S., & Campeau-Lecours, A. (2023) · Sensors · doi:10.3390/s23062927 · Cited by 200
“[28] compared high-pass filters with cutoff frequencies of 10, 30 and 60 Hz in ECG removal; they advocated for the use of the 30 Hz cutoff.”
MethodHansson, G.-Å., Nordander, C., Asterland, P., Ohlsson, K., Strömberg, U., Skerfving, S., & Rempel, D. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00030-9 · Cited by 162
Larivière, C., Gagnon, D., & Loisel, P. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00027-9 · Cited by 140
Willigenburg, N. W., Daffertshofer, A., Kingma, I., & van Dieën, J. H. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.01.001 · Cited by 120
“ECG removal procedures used to date include high-pass filtering (HPF), usually employing finite impulse response or Butterworth filters with a cut-off frequency of about 30 Hz (Redfern et al., 1993; Drake and Callaghan, 2006).”
Method
Metadata
- Authors
- Redfern, M., Hughes, R., & Chaffin, D.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-01
- Volume
- 8
- Issue
- 1
- Pages
- 44-48
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W1971611612
- Cited by
- 209
- References
- 4
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.