Data management in gait analysis for clinical applications

Benedetti, MG, Catani, F, Leardini, A, Pignotti, E, Giannini, S · 1998 · Clinical Biomechanics

Abstract

OBJECTIVE: To study the reliability of gait analysis data obtained using the Calibrated Anatomical System Technique (CAST) protocol and to verify the suitability and repeatability of the extraction of a number of parameters from the waveforms obtained. DESIGN: The experimental protocol and the parametric analysis technique were applied on a population of able-bodied subjects. BACKGROUND: The clinical interpretation process of gait data still needs a more accurate analysis of the reliability and repeatability of the measurements and a suitable procedure for data reduction useful for data comparison. METHODS: Gait analysis was performed in 20 able-bodied subjects using a stereophotogrammetric system and a forceplate. 124 parameters relative to time-distance, kinematic and kinetic variables were calculated by means of an automatic procedure and statistically analysed. RESULTS: Most of the parameters were found to be normally distributed with relatively small range of variation. Few of them showed poor repeatability, mostly due to the experimental inaccuracies introduced. Correlation of several gait parameters with age, sex, and speed of progression was also identified.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0268-0033(97)00041-7

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists are queued

They are fetched later and appear here then.

References 27 · Cited by 326

Research works printed but not linked: 3

  1. Oberg, 1994, Joint angles parameters in gait: reference data for normal subjects, 10–79 years of age, J Rehab Res Dev., 31, 199
  2. Catani, F., Benedetti, M. G., Leardini, A., Battistini, A. and Giannini, S. Functional-biomechanical evaluation of patients using a performance index. In II Annual Conference of the European Orthopaedic Research Society, EORS Transections, Varese, p. 155.
  3. Cappozzo, A., Leardini, A., Larsen, S. T., Catani, F. and Benedetti, M. G. A comparison of the accuracy of several hip centre location methods by using RSA technique. In Proceedings XVth Congress of the International Society of Biomechanics, Jyvaskyla, July 2–6, pp. 152–153.

Metadata

Authors
Benedetti, M., Catani, F., Leardini, A., Pignotti, E., & Giannini, S.
Affiliations
Istituto Ortopedico Rizzoli (IT)
Venue
Clinical Biomechanics
Publisher
Elsevier BV
Published
1998-04
Volume
13
Issue
3
Pages
204-215
ISSN
0268-0033 (ISSN-L)
OpenAlex
W2060615507
Cited by
326
References
27
Citations by year
2026: 4 · 2025: 10 · 2024: 10 · 2023: 14 · 2022: 14 · 2021: 16 · 2020: 12 · 2019: 14 · 2018: 8 · 2017: 15 · 2016: 16 · 2015: 14 · 2014: 13 · 2013: 20 · 2012: 15
FWCI
5.51
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Clinical Biomechanics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
Keywords
gait analysis, data management, measurement reliability, repeatability, stereophotogrammetry, force plate, automatic data reduction, age and sex effects, walking speed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Data management in gait analysis for clinical applications. https://app.cochat.ai/papers/10.1016/s0268-0033(97)00041-7
The paper
Benedetti, M., Catani, F., Leardini, A., Pignotti, E., & Giannini, S. (1998). Data management in gait analysis for clinical applications. Clinical Biomechanics. https://doi.org/10.1016/s0268-0033(97)00041-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.